Modeling the impact of spatial oxygen heterogeneity on radiolytic oxygen depletion during FLASH radiotherapy
Authors:
Edward Taylor,
Richard P. Hill,
Daniel Letourneau
Abstract:
It has been postulated that the delivery of radiotherapy at ultra-high dose rates ("FLASH") reduces normal tissue toxicities by depleting them of oxygen. The fraction of normal tissue and cancer cells surviving radiotherapy depends on dose and oxygen levels in an exponential manner and even a very small fraction of tissue at low oxygen levels can determine radiotherapy response. The effect of FLAS…
▽ More
It has been postulated that the delivery of radiotherapy at ultra-high dose rates ("FLASH") reduces normal tissue toxicities by depleting them of oxygen. The fraction of normal tissue and cancer cells surviving radiotherapy depends on dose and oxygen levels in an exponential manner and even a very small fraction of tissue at low oxygen levels can determine radiotherapy response. The effect of FLASH on radiation-induced normal and tumour tissue cell killing was studied by simulating oxygen diffusion, metabolism, and radiolytic oxygen depletion over domains with simulated capillary architectures. Two architectural models were used: 1.) randomly distributed capillaries and 2.) capillaries forming a regular square lattice array. The resulting oxygen partial pressure distribution histograms were used to simulate normal and tumour tissue cell survival using the linear quadratic model of cell survival, modified to incorporate oxygen-enhancement ratio (OER) effects. Tumour cell survival was found to be increased by FLASH as compared to conventional radiotherapy, with a 0-1 order of magnitude increase for expected levels of tumour hypoxia, depending on the relative magnitudes of radiolytic oxygen depletion and tissue oxygen metabolism. Interestingly, for the random capillary model, the impact of FLASH on well-oxygenated (normal) tissues was found to be much greater, with an estimated increase in cell survival by up to 10 orders of magnitude, even though reductions in mean tissue partial pressure were modest, less than 7 mmHg for the parameter values studied. The presence of very small nearly hypoxic regions in otherwise well-perfused normal tissues with high mean oxygen levels resulted in a greater proportional sparing of normal tissue than tumour cells during FLASH irradiation, possibly explaining empirical normal tissue sparing and iso-tumour control results.
△ Less
Submitted 16 May, 2022;
originally announced May 2022.
Simulated dose painting of hypoxic sub-volumes in pancreatic cancer stereotactic body radiotherapy
Authors:
Ahmed M. Elamir,
Teodor Stanescu,
Andrea Shessel,
Tony Tadic,
Ivan Yeung,
Daniel Letourneau,
John Kim,
Jelena Lukovic,
Laura A. Dawson,
Rebecca Wong,
Aisling Barry,
James Brierley,
Steven Gallinger,
Jennifer Knox,
Grainne O'Kane,
Neesha Dhani,
Ali Hosni,
Edward Taylor
Abstract:
Dose painting of hypoxic tumour sub-volumes using positron-emission tomography (PET) has been shown to improve tumour control in silico in several sites. Pancreatic cancer presents a more stringent challenge, given its proximity to critical organs-at-risk (OARs) and anatomic motion. A radiobiological model was developed to estimate clonogen survival fraction (SF), using 18F-fluoroazomycin arabinos…
▽ More
Dose painting of hypoxic tumour sub-volumes using positron-emission tomography (PET) has been shown to improve tumour control in silico in several sites. Pancreatic cancer presents a more stringent challenge, given its proximity to critical organs-at-risk (OARs) and anatomic motion. A radiobiological model was developed to estimate clonogen survival fraction (SF), using 18F-fluoroazomycin arabinoside PET (FAZA PET) images from ten patients with pancreatic cancer to quantify oxygen enhancement effects. For each patient, four simulated five-fraction stereotactic body radiotherapy (SBRT) plans were generated: 1) a standard SBRT plan aiming to cover the planning target volume with 40 Gy, 2) dose painting plans delivering escalated doses to FAZA-avid hypoxic sub-volumes, 3) dose painting plans with simulated spacer separating the duodenum and pancreatic head, and 4), plans with integrated boosts to geometric contractions of the tumour (GTV). All plans saturated at least one OAR dose limit. SF was calculated for each plan and sensitivity of SF to simulated hypoxia quantification errors was evaluated. Dose painting resulted in a 55% reduction in SF as compared to standard SBRT; 78% with spacer. Integrated boosts to hypoxia-blind geometric contractions resulted in a 41% reduction in SF. The reduction in SF for dose-painting plans persisted for all hypoxia quantification parameters studied, including registration and rigid motion errors that resulted in shifts and rotations of the GTV and hypoxic sub-volumes by as much as 1 cm and 10 degrees. Although proximity to OARs ultimately limited dose escalation, with estimated SFs (~10^-5) well above levels required to completely ablate a ~10 cm^3 tumour, dose painting robustly reduced clonogen survival when accounting for expected treatment and imaging uncertainties and thus, may improve local response and associated morbidity.
△ Less
Submitted 30 August, 2021;
originally announced August 2021.