-
Extending GPU-Accelerated Gaussian Integrals in the TeraChem Software Package to f Type Orbitals: Implementation and Applications
Authors:
Yuanheng Wang,
Diptarka Hait,
K. Grace Johnson,
O. Jonathan Fajen,
Juncheng Harry Zhang,
Rubén D. Guerrero,
Todd J. Martínez
Abstract:
The increasing availability of GPUs for scientific computing has prompted interest in accelerating quantum chemical calculations through their use. The complexity of integral kernels for high angular momentum basis functions however often limits the utility of GPU implementations with large basis sets or for metal containing systems. In this work, we report implementation of $f$ function support i…
▽ More
The increasing availability of GPUs for scientific computing has prompted interest in accelerating quantum chemical calculations through their use. The complexity of integral kernels for high angular momentum basis functions however often limits the utility of GPU implementations with large basis sets or for metal containing systems. In this work, we report implementation of $f$ function support in the GPU-accelerated TeraChem software package through the development of efficient kernels for the evaluation of Hamiltonian integrals. The high efficiency of the resulting code is demonstrated through density functional theory (DFT) calculations on increasingly large organic molecules and transition metal complexes, as well as coupled cluster singles and doubles (CCSD) calculations on water clusters. Preliminary investigations into Ni(I) catalysis with DFT and the photochemistry of MnH(CH$_3$) with complete active space self-consistent field (CASSCF) are also carried out. Overall, our GPU-accelerated software appears to be well-suited for fast simulation of large transition metal containing systems, as well as organic molecules.
△ Less
Submitted 13 October, 2024; v1 submitted 21 June, 2024;
originally announced June 2024.
-
Isotropic spin and inverse spin Hall effect in epitaxial (111)-oriented Pt/Co bilayers
Authors:
Adrián Gudín,
Alberto Anadón,
Iciar Arnay,
Rubén Guerrero,
Julio Camarero,
Sebastien Petit-Watelot,
Paolo Perna,
Juan-Carlos Rojas-Sánchez
Abstract:
The spin-to-charge current interconversion in bilayers composed of ferromagnetic and nonmagnetic layers with strong spin-orbit coupling has garnered considerable attention due to its exceptional potential in advancing spintronics devices for data storage and logic applications. Platinum (Pt) stands out as one of the most effective materials for generating spin current. While the spin conversion ef…
▽ More
The spin-to-charge current interconversion in bilayers composed of ferromagnetic and nonmagnetic layers with strong spin-orbit coupling has garnered considerable attention due to its exceptional potential in advancing spintronics devices for data storage and logic applications. Platinum (Pt) stands out as one of the most effective materials for generating spin current. While the spin conversion efficiency is isotropic in polycrystalline Pt samples, an ongoing debate persists regarding its dependence on the crystalline direction in single crystalline samples. In this study, we aim to comprehensively evaluate the in-plane anisotropy of spin-charge interconversion using an array of complementary Spin Hall and inverse Spin Hall techniques with both incoherent and coherent excitation. Specifically, we investigate the spin-to-charge interconversion in epitaxial, (111)-oriented, Co/Pt bilayers with low surface roughness, as resulted from x-ray experiments. By varying the thickness of the Pt layer, we gain insights into the spin-charge interconversion in epitaxial Pt and highlight the effects of the interfaces. Our results demonstrate an isotropic behavior within the limits of our detection uncertainty. This finding significantly enhances our understanding of spin conversion in one of the most relevant systems in spintronics and paves the way for future research in this field.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
Optimizing nucleation layers for the integration of ferroelectric HZO on CVD-grown graphene
Authors:
Suzanne Lancaster,
Iciar Arnay,
Ruben Guerrero,
Adrían Gudín,
Thomas Mikolajick,
Paolo Perna,
Stefan Slesazeck
Abstract:
Direct integration of ferroelectric Hf0.5Zr0.5O2 (HZO) on the inert surface of graphene is challenging. Here, using nucleation layers to promote atomic layer deposition of HZO was investigated. Different metals were deposited as nucleation layers via dc sputtering. Ta, which oxidizes in air to form a sub-stoichiometric oxide, was compared to Pt, which offers a more stable electrode. For thicker in…
▽ More
Direct integration of ferroelectric Hf0.5Zr0.5O2 (HZO) on the inert surface of graphene is challenging. Here, using nucleation layers to promote atomic layer deposition of HZO was investigated. Different metals were deposited as nucleation layers via dc sputtering. Ta, which oxidizes in air to form a sub-stoichiometric oxide, was compared to Pt, which offers a more stable electrode. For thicker interlayers, Ta leads to unstable switching behavior of the HZO film. Conversely, at smaller thicknesses, a higher Pr can be achieved with an oxidized Ta interlayer. In both cases, Pt offers higher endurance. The choice of interlayer may strongly depend on the required application.
△ Less
Submitted 6 September, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Towards Non-Volatile Spin Orbit Devices: Deposition of Ferroelectric Hafnia on Monolayer Graphene/Co/HM Stacks
Authors:
Suzanne Lancaster,
Iciar Arnay,
Ruben Guerrero,
Adrian Gudín,
Alejandra Guedeja-Marrón,
Jose Manuel Diez Toledano,
Jan Gärtner,
Alberto Anadón,
Maria Varela,
Julio Camarero,
Thomas Mikolajick,
Paolo Perna,
Stefan Slesazeck
Abstract:
Although technologically challenging, the integration of ferroelectric thin films with graphene spintronics potentially allows the realization of highly efficient, electrically tuneable, non-volatile memories. Here, the atomic layer deposition (ALD) of ferroelectric Hf$_{0.5}$Zr$_{0.5}$O$_2$ (HZO) directly on graphene (Gr)/Co/heavy metal (HM) epitaxial stacks is investigated via the implementation…
▽ More
Although technologically challenging, the integration of ferroelectric thin films with graphene spintronics potentially allows the realization of highly efficient, electrically tuneable, non-volatile memories. Here, the atomic layer deposition (ALD) of ferroelectric Hf$_{0.5}$Zr$_{0.5}$O$_2$ (HZO) directly on graphene (Gr)/Co/heavy metal (HM) epitaxial stacks is investigated via the implementation of several nucleation methods. With an in-situ method employing an Al$_2$O$_3$ layer, the HZO demonstrates a remanent polarization (2Pr) of 19.2 $μC/cm^2$. An ex-situ, naturally oxidized sputtered Ta layer for nucleation produces a film with 2Pr of 10.81 $μC/cm^2$, but a lower coercive field over the stack and switching enduring over subsequent cycles. Magnetic hysteresis measurements taken before and after ALD deposition show strong perpendicular magnetic anisotropy (PMA), with only slight deviations in the magnetic coercive fields due to the HZO deposition process, thus pointing to a good preservation of the single-layer Gr. X-ray diffraction measurements further confirm that the high-quality interfaces demonstrated in the stack remain unperturbed by the ferroelectric deposition and anneal.
△ Less
Submitted 23 March, 2023; v1 submitted 20 September, 2021;
originally announced September 2021.
-
White matter hyperintensity and stroke lesion segmentation and differentiation using convolutional neural networks
Authors:
R. Guerrero,
C. Qin,
O. Oktay,
C. Bowles,
L. Chen,
R. Joules,
R. Wolz,
M. C. Valdes-Hernandez,
D. A. Dickie,
J. Wardlaw,
D. Rueckert
Abstract:
The accurate assessment of White matter hyperintensities (WMH) burden is of crucial importance for epidemiological studies to determine association between WMHs, cognitive and clinical data. The manual delineation of WMHs is tedious, costly and time consuming. This is further complicated by the fact that other pathological features (i.e. stroke lesions) often also appear as hyperintense. Several a…
▽ More
The accurate assessment of White matter hyperintensities (WMH) burden is of crucial importance for epidemiological studies to determine association between WMHs, cognitive and clinical data. The manual delineation of WMHs is tedious, costly and time consuming. This is further complicated by the fact that other pathological features (i.e. stroke lesions) often also appear as hyperintense. Several automated methods aiming to tackle the challenges of WMH segmentation have been proposed, however cannot differentiate between WMH and strokes. Other methods, capable of distinguishing between different pathologies in brain MRI, are not designed with simultaneous WMH and stroke segmentation in mind. In this work we propose to use a convolutional neural network (CNN) that is able to segment hyperintensities and differentiate between WMHs and stroke lesions. Specifically, we aim to distinguish between WMH pathologies from those caused by stroke lesions due to either cortical, large or small subcortical infarcts. As far as we know, this is the first time such differentiation task has explicitly been proposed. The proposed fully convolutional CNN architecture, is comprised of an analysis path, that gradually learns low and high level features, followed by a synthesis path, that gradually combines and up-samples the low and high level features into a class likelihood semantic segmentation. Quantitatively, the proposed CNN architecture is shown to outperform other well established and state-of-the-art algorithms in terms of overlap with manual expert annotations. Clinically, the extracted WMH volumes were found to correlate better with the Fazekas visual rating score. Additionally, a comparison of the associations found between clinical risk-factors and the WMH volumes generated by the proposed method, were found to be in line with the associations found with the expert-annotated volumes.
△ Less
Submitted 2 January, 2018; v1 submitted 3 June, 2017;
originally announced June 2017.
-
Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4
Authors:
Julio F. Almansa,
Rafael Guerrero,
Feras M. O. Al-Dweri,
M. Anguiano,
A. M. Lallena
Abstract:
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Mont…
▽ More
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
△ Less
Submitted 5 December, 2006;
originally announced December 2006.
-
Monte Carlo simulation of the electron transport through thin slabs: A comparative study of PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX
Authors:
M. Vilches,
S. Garcia-Pareja,
R. Guerrero,
M. Anguiano,
A. M. Lallena
Abstract:
The Monte Carlo simulation of the electron transport through thin slabs is studied with five general purpose codes: PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX. The different material foils analyzed in the old experiments of Kulchitsky and Latyshev [Phys. Rev. 61 (1942) 254-266] and Hanson et al. [Phys. Rev. 84 (1951) 634-637] are used to perform the comparison between the Monte Carlo codes. Non-…
▽ More
The Monte Carlo simulation of the electron transport through thin slabs is studied with five general purpose codes: PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX. The different material foils analyzed in the old experiments of Kulchitsky and Latyshev [Phys. Rev. 61 (1942) 254-266] and Hanson et al. [Phys. Rev. 84 (1951) 634-637] are used to perform the comparison between the Monte Carlo codes. Non-negligible differences are observed in the angular distributions of the transmitted electrons obtained with the some of the codes. The experimental data are reasonably well described by EGSnrc, PENELOPE (v. 2005) and GEANT4. A general good agreement is found for EGSnrc and GEANT4 in all the cases analyzed.
△ Less
Submitted 5 December, 2006;
originally announced December 2006.
-
Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4
Authors:
Javier Torres,
Manuel J. Buades,
Julio F. Almansa,
Rafael Guerrero,
Antonio M. Lallena
Abstract:
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function a…
▽ More
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, respectively. Also, a comparison with the limited data available on this new source is shown. We found non negligible differences between the results obtained with PENELOPE and GEANT4.
△ Less
Submitted 21 November, 2003;
originally announced November 2003.