-
Homogeneous Linewidth Behaviour of Narrow Optical Emitters at Sub-kelvin Temperatures
Authors:
X Lin,
M T Hartman,
P Goldner,
B Fang,
Y Le Coq,
S Seidelin
Abstract:
We explore the properties of ultra-narrow spectral holes in ensembles of solid-state emitters in crystals over a range of sub-kelvin temperatures, with a focus on their potential application in frequency stabilization schemes as an alternative to ultrastable cavities. We investigate how the parameters used to burn the spectral hole impact its shape, and how these factors determine the minimum achi…
▽ More
We explore the properties of ultra-narrow spectral holes in ensembles of solid-state emitters in crystals over a range of sub-kelvin temperatures, with a focus on their potential application in frequency stabilization schemes as an alternative to ultrastable cavities. We investigate how the parameters used to burn the spectral hole impact its shape, and how these factors determine the minimum achievable linewidth. In addition to the stability of the hole's center frequency, the linewidth and contrast play a crucial role in frequency locking. At sub-kelvin temperatures, the temperaturedependent T^7 broadening from two-phonon Raman scattering is expected to be negligible, and the spectral hole's linewidth should therefore remain constant in this interval. We observe however a linear broadening with increasing temperature, highlighting the need for further investigation into the mechanisms governing the linewidth at ultra-low temperatures.
△ Less
Submitted 6 December, 2024;
originally announced December 2024.
-
Anomalous sub-kelvin thermal frequency shifts of ultra narrow-linewidth solid state emitters
Authors:
X. Lin,
M. T. Hartman,
B. Pointard,
R. Le Targat,
P. Goldner,
S. Seidelin,
B. Fang,
Y. Le Coq
Abstract:
We investigate the frequency response of narrow spectral holes in a doped crystal structure as a function of temperature below 1 K. We identify a particular regime in which this response significantly deviates from the expected two-phonon Raman scattering theory. Namely, near 290 mK, we observed a behaviour exhibiting a temperature-dependent frequency shift of zero, to first-order. This is of part…
▽ More
We investigate the frequency response of narrow spectral holes in a doped crystal structure as a function of temperature below 1 K. We identify a particular regime in which this response significantly deviates from the expected two-phonon Raman scattering theory. Namely, near 290 mK, we observed a behaviour exhibiting a temperature-dependent frequency shift of zero, to first-order. This is of particular interest for applications which require high frequency-stability, such as laser frequency stabilization, as by operating the scheme at this specific point would result in the spectral hole frequency being highly immune to temperature fluctuations, providing the potential for a laser fractional frequency instability as low as $\mathrm{\sim6\times10^{-22}}$ at 1 s.
△ Less
Submitted 8 November, 2024;
originally announced November 2024.
-
First-order thermal insensitivity of the frequency of a narrow spectral hole in a crystal
Authors:
S. Zhang,
S. Seidelin,
R. Le Targat,
P. Goldner,
B. Fang,
Y. Le Coq
Abstract:
The possibility of generating an narrow spectral hole in a rare-earth doped crystal opens the gateway to a variety of applications, one of which is the realization of an ultrastable laser. As this is achieved by locking in a pre-stabilized laser to the narrow hole, a prerequisite is the elimination of frequency fluctuations of the spectral hole. One potential source of such fluctuations can arise…
▽ More
The possibility of generating an narrow spectral hole in a rare-earth doped crystal opens the gateway to a variety of applications, one of which is the realization of an ultrastable laser. As this is achieved by locking in a pre-stabilized laser to the narrow hole, a prerequisite is the elimination of frequency fluctuations of the spectral hole. One potential source of such fluctuations can arise from temperature instabilities. However, when the crystal is surrounded by a buffer gas subject to the same temperature as the crystal, the effect of temperature-induced pressure changes may be used to counterbalance the direct effect of temperature fluctuations. For a particular pressure, it is indeed possible to identify a temperature for which the spectral hole resonant frequency is independent of the first-order thermal fluctuations. Here, we measure frequency shifts as a function of temperature for different values of the pressure of the surrounding buffer gas, and identify the ``magic'' environment within which the spectral hole is largely insensitive to temperature.
△ Less
Submitted 5 November, 2024;
originally announced November 2024.
-
Multi-mode Heterodyne Laser Interferometry Realized via Software Defined Radio
Authors:
X. Lin,
M. T. Hartman,
S. Zhang,
S. Seidelin,
B. Fang,
Y. Le Coq
Abstract:
The agile generation and control of multiple optical frequency modes combined with the realtime processing of multi-mode data provides access to experimentation in domains such as optomechanical systems, optical information processing, and multi-mode spectroscopy. The latter, specifically spectroscopy of spectral-hole burning (SHB), has motivated our development of a multi-mode heterodyne laser in…
▽ More
The agile generation and control of multiple optical frequency modes combined with the realtime processing of multi-mode data provides access to experimentation in domains such as optomechanical systems, optical information processing, and multi-mode spectroscopy. The latter, specifically spectroscopy of spectral-hole burning (SHB), has motivated our development of a multi-mode heterodyne laser interferometric scheme centered around a software-defined radio platform for signal generation and processing, with development in an entirely open-source environment. A challenge to SHB is the high level of shot noise due to the laser power constraint imposed by the spectroscopic sample. Here, we have demonstrated the production, detection, and separation of multiple optical frequency modes to the benefit of optical environment sensing for realtime phase noise subtraction as well as shot noise reduction through multi-mode averaging. This has allowed us to achieve improved noise performance in low-optical-power interferometry. Although our target application is laser stabilization via SHB in cryogenic temperature rare-earth doped crystals, these techniques may be employed in a variety of different contexts.
△ Less
Submitted 5 October, 2023;
originally announced October 2023.
-
Precision measurements of electric-field-induced frequency displacements of an ultranarrow optical transition in ions in a solid
Authors:
S. Zhang,
N. Lučić,
N. Galland,
R. Le Targat,
P. Goldner,
B. Fang,
S. Seidelin,
Y. Le Coq
Abstract:
We report a series of measurements of the effect of an electric field on the frequency of the ultranarrow linewidth $^7F_0 \rightarrow$ $^5D_0$ optical transition of $\rm Eu^{3+}$ ions in an $\rm Y_2SiO_5$ matrix at cryogenic temperatures. We provide linear Stark coefficients along two dielectric axes and for the two different substitution sites of the $\rm Eu^{3+}$ ions, with an unprecedented acc…
▽ More
We report a series of measurements of the effect of an electric field on the frequency of the ultranarrow linewidth $^7F_0 \rightarrow$ $^5D_0$ optical transition of $\rm Eu^{3+}$ ions in an $\rm Y_2SiO_5$ matrix at cryogenic temperatures. We provide linear Stark coefficients along two dielectric axes and for the two different substitution sites of the $\rm Eu^{3+}$ ions, with an unprecedented accuracy, and an upper limit for the quadratic Stark shift. The measurements, which indicate that the electric field sensitivity is a factor of seven larger for site 1 relative to site 2 for a particular direction of the electric field are of direct interest both in the context of quantum information processing and laser frequency stabilization with rare-earth doped crystals, in which electric fields can be used to engineer experimental protocols by tuning transition frequencies.
△ Less
Submitted 26 January, 2021; v1 submitted 25 January, 2021;
originally announced January 2021.
-
Inhomogeneous response of an ion ensemble from mechanical stress
Authors:
S. Zhang,
N. Galland,
N. Lučić,
R. Le Targat,
A. Ferrier,
P. Goldner,
B. Fang,
Y. Le Coq,
S. Seidelin
Abstract:
Material strain has recently received growing attention as a complementary resource to control the energy levels of quantum emitters embedded inside a solid-state environment. Some rare-earth ion dopants provide an optical transition which simultaneously has a narrow linewidth and is highly sensitive to strain. In such systems, the technique of spectral hole burning, in which a transparent window…
▽ More
Material strain has recently received growing attention as a complementary resource to control the energy levels of quantum emitters embedded inside a solid-state environment. Some rare-earth ion dopants provide an optical transition which simultaneously has a narrow linewidth and is highly sensitive to strain. In such systems, the technique of spectral hole burning, in which a transparent window is burnt within the large inhomogeneous profile, allows to benefit from the narrow features, which are also sensitive to strain, while working with large ensembles of ions. However, working with ensembles may give rise to inhomogeneous responses among different ions. We investigate experimentally how the shape of a narrow spectral hole is modified due to external mechanical strain, in particular, the hole broadening as a function of the geometry of the crystal sites and the crystalline axis along which the stress is applied. Studying these effects are essential in order to optimize the existing applications of rare-earth doped crystals in fields which already profit from the more well-established coherence properties of these dopants such as frequency metrology and quantum information processing, or even suggest novel applications of these materials, for example as robust devices for force-sensing or highly sensitive accelerometers.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
Microscale crystalline rare-earth doped resonators for strain-coupled optomechanics
Authors:
J. F. Motte,
N. Galland,
J. Debray,
A. Ferrier,
P. Goldner,
N. Lučić,
S. Zhang,
B. Fang,
Y. Le Coq,
S. Seidelin
Abstract:
Rare-earth ion doped crystals for hybrid quantum technologies is an area of growing interest in the solid-state physics community. We have earlier theoretically proposed a hybrid scheme of a mechanical resonator which is fabricated out of a rare-earth doped mono-crystalline structure. The rare-earth ion dopants have absorption energies which are sensitive to crystal strain, and it is thus possible…
▽ More
Rare-earth ion doped crystals for hybrid quantum technologies is an area of growing interest in the solid-state physics community. We have earlier theoretically proposed a hybrid scheme of a mechanical resonator which is fabricated out of a rare-earth doped mono-crystalline structure. The rare-earth ion dopants have absorption energies which are sensitive to crystal strain, and it is thus possible to couple the ions to the bending motion of the crystal cantilever. Here, we present the design and fabrication method based on focused-ion-beam etching techniques which we have successfully employed in order to create such microscale resonators, as well as the design of the environment which will allow to study the quantum behavior of the resonators.
△ Less
Submitted 9 April, 2020; v1 submitted 7 April, 2020;
originally announced April 2020.
-
Double-heterodyne probing for ultra-stable laser based on spectral hole burning in a rare-earth doped crystal
Authors:
N. Galland,
N. Lucic,
S. Zhang,
H. Alvarez-Martinez,
R. Le Targat,
A. Ferrier,
P. Goldner,
B. Fang,
S. Seidelin,
Y. Le Coq
Abstract:
We present an experimental technique for realizing a specific absorption spectral pattern in a rare-earth-doped crystal at cryogenic temperatures. This pattern is subsequently probed on two spectral channels simultaneously, thereby producing an error signal allowing frequency locking of a laser on the said spectral pattern. Appropriate combination of the two channels leads to a substantial reducti…
▽ More
We present an experimental technique for realizing a specific absorption spectral pattern in a rare-earth-doped crystal at cryogenic temperatures. This pattern is subsequently probed on two spectral channels simultaneously, thereby producing an error signal allowing frequency locking of a laser on the said spectral pattern. Appropriate combination of the two channels leads to a substantial reduction of the detection noise, paving the way to realizing an ultra-stable laser for which the detection noise can be made arbitrarily low when using multiple channels. We use such technique to realize a laser with a frequency instability of $1.7\times 10^{-15}$ at 1 second, not limited by the detection noise but by environmental perturbation of the crystal. This is comparable with the lowest instability demonstrated at 1 second to date for rare-earth doped crystal stabilized lasers.
△ Less
Submitted 3 April, 2020;
originally announced April 2020.
-
Mechanical tunability of an ultra-narrow spectral feature with uniaxial stress
Authors:
N. Galland,
N. Lucic,
B. Fang,
S. Zhang,
R. Letargat,
A. Ferrier,
P. Goldner,
S. Seidelin,
Y. Le Coq
Abstract:
Rare-earth doped crystals have numerous applications ranging from frequency metrology to quantum information processing. To fully benefit from their exceptional coherence properties, the effect of mechanical strain on the energy levels of the dopants - whether it is a resource or perturbation - needs to be considered. We demonstrate that by applying uniaxial stress to a rare-earth doped crystal co…
▽ More
Rare-earth doped crystals have numerous applications ranging from frequency metrology to quantum information processing. To fully benefit from their exceptional coherence properties, the effect of mechanical strain on the energy levels of the dopants - whether it is a resource or perturbation - needs to be considered. We demonstrate that by applying uniaxial stress to a rare-earth doped crystal containing a spectral hole, we can shift the hole by a controlled amount that is larger than the width of the hole. We deduce the sensitivity of $\rm Eu^{3+}$ ions in an $\rm Y_2SiO_5$ matrix as a function of crystal site and the crystalline axis along which the stress is applied.
△ Less
Submitted 18 December, 2019;
originally announced December 2019.
-
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
Authors:
A Cournol,
M. Manceau,
M. Pierens,
L Lecordier,
D Tran,
R. Santagata,
B. Argence,
A Goncharov,
O. Lopez,
M. Abgrall,
Y. Le Coq,
R. Le Targat,
H Alvarez Martinez,
W Lee,
D Xu,
P-E Pottie,
R Hendricks,
T Wall,
J Bieniewska,
B Sauer,
M. Tarbutt,
A. Amy-Klein,
S. Tokunaga,
B. Darquié
Abstract:
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We re…
▽ More
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesized.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
Authors:
R. Santagata,
D. Tran,
B. Argence,
O. Lopez,
S. Tokunaga,
F. Wiotte,
H. Mouhamad,
A. Goncharov,
M. Abgrall,
Y. Le Coq,
H. Alvarez-Martinez,
R. Le Targat,
W. Lee,
D. Xu,
P. -E. Pottie,
B. Darquié,
A. Amy-Klein
Abstract:
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a…
▽ More
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a widely tunable ultra-narrow Quantum Cascade Laser (QCL), an optical frequency comb and a compact multipass cell. The QCL frequency is stabilized onto a comb controlled with a remote near-infrared ultra-stable laser, transferred through a fiber link. The resulting QCL frequency stability is below 10-15 from 0.1 to 10s and its frequency uncertainty of 4x10-14 is given by the remote frequency standards. Continuous tuning over ~400 MHz is reported. We use the apparatus to perform saturated absorption spectroscopy of methanol in the low-pressure multipass cell and demonstrate a statistical uncertainty at the kHz level on transition center frequencies, confirming its potential for driving the next generation technology required for precise spectroscopic measurements.
△ Less
Submitted 23 July, 2019;
originally announced July 2019.
-
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Rapid cooling of a strain-coupled oscillator by optical phaseshift measurement
Authors:
Signe Seidelin,
Yann Le Coq,
Klaus Mølmer
Abstract:
We consider an optical probe that interacts with an ensemble of rare earth ions doping a materialin the shape of a cantilever. By optical spectral hole burning, the inhomogeneously broadenedtransition in the ions is prepared to transmit the probe field within a narrow window, but bendingof the cantilever causes strain in the material which shifts the ion resonances. The motion of thecantilever may…
▽ More
We consider an optical probe that interacts with an ensemble of rare earth ions doping a materialin the shape of a cantilever. By optical spectral hole burning, the inhomogeneously broadenedtransition in the ions is prepared to transmit the probe field within a narrow window, but bendingof the cantilever causes strain in the material which shifts the ion resonances. The motion of thecantilever may thus be registered by the phase shift of the probe. By continuously measuringthe optical field we induce a rapid reduction of the position and momentum uncertainty of thecantilever. Doing so, the probing extracts entropy and thus effectively cools the thermal state ofmotion towards a known, conditional oscillatory motion with strongly reduced thermal fluctuations.Moreover, as the optical probe provides a force on the resonator proportional to its intensity, it ispossible to exploit the phase shift measurements in order to create an active feedback loop, whicheliminates the thermal fluctuations of the resonator. We describe this system theoretically, andprovide numerical simulations which demonstrate the rapid reduction in resonator position andmomentum uncertainty, as well as the implementation of the active cooling protocol.
△ Less
Submitted 10 May, 2019;
originally announced May 2019.
-
Phase noise characterization of sub-hertz linewidth lasers via digital cross correlation
Authors:
Xiaopeng Xie,
Romain Bouchand,
Daniele Nicolodi,
Michel Lours,
Christophe Alexandre,
Yann Le Coq
Abstract:
Phase noise or frequency noise is a key metrics to evaluate the short term stability of a laser. This property is of a great interest for the applications but delicate to characterize, especially for narrow line-width lasers. In this letter, we demonstrate a digital cross correlation scheme to characterize the absolute phase noise of sub-hertz line-width lasers. Three 1,542 nm ultra-stable lasers…
▽ More
Phase noise or frequency noise is a key metrics to evaluate the short term stability of a laser. This property is of a great interest for the applications but delicate to characterize, especially for narrow line-width lasers. In this letter, we demonstrate a digital cross correlation scheme to characterize the absolute phase noise of sub-hertz line-width lasers. Three 1,542 nm ultra-stable lasers are used in this approach. For each measurement two lasers act as references to characterize a third one. Phase noise power spectral density from 0.5 Hz to 0.8 MHz Fourier frequencies can be derived for each laser by a mere change in the configuration of the lasers. This is the first time showing the phase noise of sub-hertz line-width lasers with no reference limitation. We also present an analysis of the laser phase noise performance.
△ Less
Submitted 17 March, 2017;
originally announced March 2017.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Photonic microwave signals with zeptosecond level absolute timing noise
Authors:
Xiaopeng Xie,
Romain Bouchand,
Daniele Nicolodi,
Michele Giunta,
Wolfgang Hänsel,
Matthias Lezius,
Abhay Joshi,
Shubhashish Datta,
Christophe Alexandre,
Michel Lours,
Pierre-Alain Tremblin,
Giorgio Santarelli,
Ronald Holzwarth,
Yann Le Coq
Abstract:
Photonic synthesis of radiofrequency revived the quest for unrivalled microwave purity by its seducing ability to convey the benefits of the optics to the microwave world. In this work, we perform a high-fidelity transfer of frequency stability between an optical reference and a microwave signal via a low-noise fiber-based frequency comb and cutting-edge photo-detection techniques. We demonstrate…
▽ More
Photonic synthesis of radiofrequency revived the quest for unrivalled microwave purity by its seducing ability to convey the benefits of the optics to the microwave world. In this work, we perform a high-fidelity transfer of frequency stability between an optical reference and a microwave signal via a low-noise fiber-based frequency comb and cutting-edge photo-detection techniques. We demonstrate the generation of the purest microwave signal with a fractional frequency stability below 6.5 x 10^-16 at 1 s and a timing noise floor below 41 zs.Hz^-1/2 (phase noise below -173 dBc.Hz^-1 for a 12 GHz carrier). This outclasses existing sources and promises a new era for state-of-the-art microwave generation. The characterization is achieved by building two auxiliary low noise optoelectronic microwave reference and using a heterodyne cross-correlation scheme with lowermost detection noise. This unprecedented level of purity can impact domains such as radar systems, telecommunications and time-frequency metrology. Furthermore, the measurement methods developed here can benefit the characterization of a broad range of signals, beyond comb-based systems.
△ Less
Submitted 5 October, 2016;
originally announced October 2016.
-
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Authors:
Jérôme Lodewyck,
Sławomir Bilicki,
Eva Bookjans,
Jean-Luc Robyr,
Chunyan Shi,
Grégoire Vallet,
Rodolphe Le Targat,
Daniele Nicolodi,
Yann Le Coq,
Jocelyne Guéna,
Michel Abgrall,
Peter Rosenbusch,
Sébastien Bize
Abstract:
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th…
▽ More
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
△ Less
Submitted 12 May, 2016;
originally announced May 2016.
-
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Authors:
R Tyumenev,
M Favier,
S Bilicki,
E Bookjans,
R Le Targat,
J Lodewyck,
D Nicolodi,
Y Le Coq,
M Abgrall,
J Guéna,
L De Sarlo,
S Bize
Abstract:
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta…
▽ More
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.
△ Less
Submitted 13 November, 2016; v1 submitted 7 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Quantum cascade laser frequency stabilisation at the sub-Hz level
Authors:
Bérengère Argence,
Bruno Chanteau,
Olivier Lopez,
Daniele Nicolodi,
Michel Abgrall,
Christian Chardonnet,
Christophe Daussy,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. T…
▽ More
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.
△ Less
Submitted 6 December, 2014;
originally announced December 2014.
-
Spectral purity transfer between optical wavelengths at the $10^{-18}$ level
Authors:
Daniele Nicolodi,
Béengère Argence,
Wei Zhang,
Rodolphe Le Targat,
Giorgio Santarelli,
Yann Le Coq
Abstract:
Ultra-stable lasers and optical frequency combs have been the enabling technologies for the tremendous progress of precise optical spectroscopy in the last ten years. To improve laser frequency stabilization beyond the thermal-noise fundamental limit of traditional room-temperature high-finesse optical cavities, new solutions have been recently developed. These being complex and often wavelength s…
▽ More
Ultra-stable lasers and optical frequency combs have been the enabling technologies for the tremendous progress of precise optical spectroscopy in the last ten years. To improve laser frequency stabilization beyond the thermal-noise fundamental limit of traditional room-temperature high-finesse optical cavities, new solutions have been recently developed. These being complex and often wavelength specific, the capability to transfer their spectral purity to any optical wavelengths is highly desirable. Here we present an optical frequency comb based scheme transferring a $4.5 \times 10^{-16}$ fractional frequency stability from a 1062 nm wavelength laser to a 1542 nm laser. We demonstrate that this scheme does not hinder the transfer down to $3 \times 10^{-18}$ at one second, two orders of magnitude below previously reported work with comparable systems. This exceeds by more than one order of magnitude the stability of any optical oscillator demonstrated to date, and satisfies the stability requirement for quantum-projection-noise limited optical lattice clocks.
△ Less
Submitted 18 November, 2013;
originally announced November 2013.
-
Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy
Authors:
Bruno Chanteau,
Olivier Lopez,
Wei Zhang,
Daniele Nicolodi,
Bérengère Argence,
Frédéric Auguste,
Michel Abgrall,
Christian Chardonnet,
Giorgio Santarelli,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertai…
▽ More
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.
△ Less
Submitted 29 April, 2013;
originally announced April 2013.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Mid-IR frequency measurement using an optical frequency comb and a long-distance remote frequency reference
Authors:
Bruno Chanteau,
Olivier Lopez,
Wei Zhang,
Giorgio Santarelli,
Yann Le Coq,
Frédéric Auguste,
Benoît Darquié,
Christian Chardonnet,
Anne Amy-Klein
Abstract:
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-…
▽ More
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.
△ Less
Submitted 13 October, 2012;
originally announced October 2012.
-
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
Authors:
J. J. McFerran,
D. V. Magalhaes,
C. Mandache,
J. Millo,
W. Zhang,
Y. Le Coq,
G. Santarelli,
S. Bize
Abstract:
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.…
▽ More
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.6 nm fiber laser locked to an ultrastable optical cavity that exhibits a mean drift rate of -6.0x10^(-17) s^(-1) (or -16.9 mHz.s^(-1) at 282 THz) over a five month period. A comparison between two such lasers locked to independent optical cavities shows a flicker noise limited fractional frequency instability of 4x10^(-16) per cavity.
△ Less
Submitted 2 July, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
Authors:
J. J. McFerran,
L. Yi,
S. Mejri,
S. Di Manno,
W. Zhang,
J. Guéna,
Y. Le Coq,
S. Bize
Abstract:
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are load…
▽ More
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are loaded from a single stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. The frequency of the clock transition is found to be 1 128 575 290 808 162.0 +/-6.4 (sys.) +/-0.3 (stat.) Hz (fractional uncertainty = 5.7x10^(-15)). Neither an atom number nor second order Zeeman dependence have yet to be detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing and detection.
△ Less
Submitted 17 January, 2012;
originally announced January 2012.
-
Characterizing a fiber-based frequency comb with electro-optic modulator
Authors:
W. Zhang,
M. Lours,
M. Fischer,
R. Holzwarth,
G. Santarelli,
Y. Le Coq
Abstract:
We report on the characterization of a commercial-core fiber-based frequency comb equipped with an intracavity electro-optic modulator (EOM). We investigate the relationship between the noise of the pump diode and the laser relative intensity noise (RIN) and demonstrate the use of a low noise current supply to substantially reduce the laser RIN. By measuring several transfer functions, we evaluate…
▽ More
We report on the characterization of a commercial-core fiber-based frequency comb equipped with an intracavity electro-optic modulator (EOM). We investigate the relationship between the noise of the pump diode and the laser relative intensity noise (RIN) and demonstrate the use of a low noise current supply to substantially reduce the laser RIN. By measuring several transfer functions, we evaluate the potentiality of the EOM for comb repetition rate stabilization. We also evaluate the coupling to other relevant parameters of the comb. From these measureemnts, we infer the capabilities of the femtosecond laser comb to generate very low phase noise microwave signals when phase locked to a high spectral purity ultra-stable laser.
△ Less
Submitted 14 September, 2011;
originally announced September 2011.
-
An Optical Fibre Pulse Rate Multiplier for Ultra-low Phase-noise Signal Generation
Authors:
A. Haboucha,
W. Zhang,
T. Li,
M Lours,
A. N. Luiten,
Y. Le Coq,
G. Santarelli
Abstract:
In this letter we report on an all optical-fibre approach to the synthesis of ultra-low noise microwave signals by photodetection of femtosecond laser pulses. We use a cascade of Mach-Zehnder fibre interferometers to realize stable and efficient repetition rate multiplication. This technique increases the signal level of the photodetected microwave signal by close to 18 dB, that in turn, allows us…
▽ More
In this letter we report on an all optical-fibre approach to the synthesis of ultra-low noise microwave signals by photodetection of femtosecond laser pulses. We use a cascade of Mach-Zehnder fibre interferometers to realize stable and efficient repetition rate multiplication. This technique increases the signal level of the photodetected microwave signal by close to 18 dB, that in turn, allows us to demonstrate a phase noise level of 118 dBc/Hz at 1 Hz and -160 dBc/Hz at 10 MHz from 12 GHz signal. The noise floor of the fiber multiplier and photodetection system alone is around -164 dBc/Hz at the same offset frequency, which is very close to the fundamental shot noise floor
△ Less
Submitted 26 August, 2011; v1 submitted 26 June, 2011;
originally announced June 2011.
-
Amplitude to phase conversion of InGaAs pin photo-diodes for femtosecond lasers microwave signal generation
Authors:
W. Zhang,
T. Li,
M. Lours,
S. Seidelin,
G. Santarelli,
Y. Le Coq
Abstract:
When a photo-diode is illuminated by a pulse train from a femtosecond laser, it generates microwaves components at the harmonics of the repetition rate within its bandwidth. The phase of these components (relative to the optical pulse train) is known to be dependent on the optical energy per pulse. We present an experimental study of this dependence in InGaAs pin photo-diodes illuminated with ultr…
▽ More
When a photo-diode is illuminated by a pulse train from a femtosecond laser, it generates microwaves components at the harmonics of the repetition rate within its bandwidth. The phase of these components (relative to the optical pulse train) is known to be dependent on the optical energy per pulse. We present an experimental study of this dependence in InGaAs pin photo-diodes illuminated with ultra-short pulses generated by an Erbium-doped fiber based femtosecond laser. The energy to phase dependence is measured over a large range of impinging pulse energies near and above saturation for two typical detectors, commonly used in optical frequency metrology with femtosecond laser based optical frequency combs. When scanning the optical pulse energy, the coefficient which relates phase variations to energy variations is found to alternate between positive and negative values, with many (for high harmonics of the repetition rate) vanishing points. By operating the system near one of these vanishing points, the typical amplitude noise level of commercial-core fiber-based femtosecond lasers is sufficiently low to generate state-of-the-art ultra-low phase noise microwave signals, virtually immune to amplitude to phase conversion related noise.
△ Less
Submitted 22 April, 2011;
originally announced April 2011.
-
Advanced noise reduction techniques for ultra-low phase noise optical-to-microwave division with femtosecond fiber combs
Authors:
W. Zhang,
Z. Xu,
M. Lours,
R. Boudot,
Y. Kersale,
A. N. Luiten,
Y. Le Coq,
G. Santarelli
Abstract:
We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120dBc/Hz at 1 Hz offset from a 11.55GHz carrier frequency. We furthermore report a detailed investigation into the fundamental noise sources which afflicts the division process itself. Two frequency combs with quasi-identi…
▽ More
We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120dBc/Hz at 1 Hz offset from a 11.55GHz carrier frequency. We furthermore report a detailed investigation into the fundamental noise sources which afflicts the division process itself. Two frequency combs with quasi-identical configurations are referenced to a common ultrastable cavity laser source. To identify each of the limiting effects we implement an ultra-low noise carrier-suppression measurement system, which circumvents the detection and amplification noise of more conventional techniques. This technique now allows the suppression of these unwanted sources of noise to very low levels. In the Fourier frequency range of ~200 Hz to 100 kHz, a fed-forward technique based on a voltage-controlled phase shifter delivers a further noise reduction of 10 dB. For lower Fourier frequencies, optical power stabilization is implemented in order to reduce the relative intensity noise which causes unwanted phase noise through power to phase conversion in the detector. We implement and compare two possible control schemes based on an acousto-optical modulator and comb pump current. We also present wideband measurements on the relative intensity noise of the fiber comb.
△ Less
Submitted 9 March, 2011; v1 submitted 3 December, 2010;
originally announced December 2010.
-
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
Authors:
S. T. Dawkins,
R. Chicireanu,
M. Petersen,
J. Millo,
D. V. Magalhães,
C. Mandache,
Y. Le Coq,
S. Bize
Abstract:
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low the…
▽ More
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low thermal noise limits associated with this material. By stabilizing the frequency of a 1062.6 nm Yb-doped fiber laser to the cavity, and including an additional link to LNE-SYRTE's fountain primary frequency standards via an optical frequency comb, we produce a signal which is both stable at the 1E-15 level in fractional terms and referenced to primary frequency standards. The signal is subsequently amplified and frequency-doubled twice to produce several milliwatts of interrogation signal at 265.6 nm in the deep ultraviolet.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Sub-100 attoseconds optics-to-microwave synchronization
Authors:
W. Zhang,
Z. Xu,
M. Lours,
R. Boudot,
Y. Kersale,
G. Santarelli,
Y. Le Coq
Abstract:
We use two fiber-based femtosecond frequency combs and a low-noise carrier suppression phase detection system to characterize the optical to microwave synchronization achievable with such frequency divider systems. By applying specific noise reduction strategies, a residual phase noise as low as -120 dBc/Hz at 1 Hz offset frequency from a 11.55 GHz carrier is measured. The fractional frequency ins…
▽ More
We use two fiber-based femtosecond frequency combs and a low-noise carrier suppression phase detection system to characterize the optical to microwave synchronization achievable with such frequency divider systems. By applying specific noise reduction strategies, a residual phase noise as low as -120 dBc/Hz at 1 Hz offset frequency from a 11.55 GHz carrier is measured. The fractional frequency instability from a single optical-to-frequency divider is 1.1E-16 at 1 s averaging down to below 2E-19 after only 1000 s. The corresponding rms time deviation is lower than 100 attoseconds up to 1000 s averaging duration.
△ Less
Submitted 14 March, 2010;
originally announced March 2010.
-
Ultra-Low Noise Microwave Extraction from Fiber-Based Optical Frequency Comb
Authors:
J. Millo,
R. Boudot,
M. Lours,
P. Y. Bourgeois,
A. N. Luiten,
Y. Le Coq,
Y. Kersale,
G. Santarelli
Abstract:
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived f…
▽ More
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived from the two optical frequency combs is below 2.3 10^(-16) at 1s and about 4 10^(-19) at 6.5 10^(4)s (in 5 Hz bandwidth, three days continuous operation).
△ Less
Submitted 21 November, 2009; v1 submitted 25 June, 2009;
originally announced June 2009.
-
Ultrastable lasers based on vibration insensitive cavities
Authors:
J. Millo,
D. V. Magalhaes,
C. Mandache,
Y. Le Coq,
E. M. L. English,
P. G. Westergaard,
J. Lodewyck,
S. Bize,
P. Lemonde,
G. Santarelli
Abstract:
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better…
▽ More
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6e-16 at 1 second, which is the best result obtained for this length of cavity.
△ Less
Submitted 4 May, 2009; v1 submitted 29 January, 2009;
originally announced January 2009.
-
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
Authors:
J. Millo,
M. Abgrall,
M. Lours,
E. M. L. English,
H. Jiang,
J. Guena,
A. Clairon,
S. Bize,
Y. Le Coq,
G. Santarelli,
M. E. Tobar
Abstract:
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used t…
▽ More
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.
△ Less
Submitted 23 January, 2009;
originally announced January 2009.
-
Sr lattice clock at 1x10^{-16} fractional uncertainty by remote optical evaluation with a Ca clock
Authors:
A. D. Ludlow,
T. Zelevinsky,
G. K. Campbell,
S. Blatt,
M. M. Boyd,
M. H. G. de Miranda,
M. J. Martin,
J. W. Thomsen,
S. M. Foreman,
Jun Ye,
T. M. Fortier,
J. E. Stalnaker,
S. A. Diddams,
Y. Le Coq,
Z. W. Barber,
N. Poli,
N. D. Lemke,
K. M. Beck,
C. W. Oates
Abstract:
Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over km-scale urban distances, a key step for development, dissemination, and application of these optical standards. Throug…
▽ More
Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over km-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1x10-16 fractional level, surpassing the best current evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.
△ Less
Submitted 28 March, 2008; v1 submitted 28 January, 2008;
originally announced January 2008.
-
Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Yann Le Coq,
Giovanni D. Rovera,
Sebastien Bize,
Pierre Lemonde
Abstract:
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss…
▽ More
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.
△ Less
Submitted 14 March, 2007;
originally announced March 2007.
-
Measurement of excited-state transitions in cold calcium atoms by direct femtosecond frequency-comb spectroscopy
Authors:
J. E. Stalnaker,
Y. Le Coq,
T. M. Fortier,
S. A. Diddams,
C. W. Oates,
L. Hollberg
Abstract:
We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency in cold calcium atoms. A 657 nm ultrastable cw laser was used to excite atoms on the narrow ($γ\sim 400$ Hz) ${\rm 4s^2} ^1S_0 \to {\rm 4s4p} ^3P_1$ clock transition, and the direct output of the frequency comb was used to excite…
▽ More
We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency in cold calcium atoms. A 657 nm ultrastable cw laser was used to excite atoms on the narrow ($γ\sim 400$ Hz) ${\rm 4s^2} ^1S_0 \to {\rm 4s4p} ^3P_1$ clock transition, and the direct output of the frequency comb was used to excite those atoms from the ${\rm 4s4p} ^3P_1$ state to the ${\rm 4s5s} ^3S_1$ state. The resonance of this second stage was detected by observing a decrease in population of the ground state as a result of atoms being optically pumped to the metastable ${\rm 4s4p} ^3P_{0,2}$ states. The ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency is measured to be $ν= 489 544 285 713(56)$ kHz; which is an improvement by almost four orders of magnitude over the previously measured value. In addition, we demonstrate spectroscopy on magnetically trapped atoms in the ${\rm 4s4p} ^3P_2$ state.
△ Less
Submitted 16 January, 2007;
originally announced January 2007.
-
Kilohertz-resolution spectroscopy of cold atoms with an optical frequency comb
Authors:
T. M. Fortier,
Y. Le Coq,
J. E. Stalnaker,
D. Ortega,
S. A. Diddams,
C. W. Oates,
L. Hollberg
Abstract:
We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the…
▽ More
We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the laser in both regimes was used to perform kilohertz-level spectroscopy. This experiment demonstrates the potential for high-resolution absolute-frequency spectroscopy over the entire spectrum of the frequency comb output using a single high-finesse optical reference cavity.
△ Less
Submitted 3 May, 2006;
originally announced May 2006.
-
Tapered-amplified AR-coated laser diodes for Potassium and Rubidium atomic-physics experiments
Authors:
Robert A. Nyman,
Gael Varoquaux,
Brice Villier,
Delphine Sacchet,
Frédéric Moron,
Yann Le Coq,
Alain Aspect,
Philippe Bouyer
Abstract:
We present a system of room-temperature extended-cavity grating-diode lasers (ECDL) for production of light in the range 760-790nm. The extension of the tuning range towards the blue is permitted by the weak feedback in the cavity: the diodes are anti-reflection coated, and the grating has just 10% reflectance. The light is then amplified using semiconductor tapered amplifiers to give more than…
▽ More
We present a system of room-temperature extended-cavity grating-diode lasers (ECDL) for production of light in the range 760-790nm. The extension of the tuning range towards the blue is permitted by the weak feedback in the cavity: the diodes are anti-reflection coated, and the grating has just 10% reflectance. The light is then amplified using semiconductor tapered amplifiers to give more than 400mW of power. The outputs are shown to be suitable for atomic physics experiments with potassium (767nm), rubidium (780nm) or both, of particular relevance to doubly-degenerate boson-fermion mixtures.
△ Less
Submitted 30 November, 2005;
originally announced November 2005.
-
Beam quality of a non-ideal atom laser
Authors:
J. -F. Riou,
W. Guerin,
Y. Le Coq,
M. Fauquembergue,
Philippe Bouyer,
V. Josse,
Alain Aspect
Abstract:
We study the propagation of a non-interacting atom laser distorted by the strong lensing effect of the Bose-Einstein Condensate (BEC) from which it is outcoupled. We observe a transverse structure containing caustics that vary with the density within the residing BEC. Using WKB approximation, Fresnel-Kirchhoff integral formalism and ABCD matrices, we are able to describe analytically the atom la…
▽ More
We study the propagation of a non-interacting atom laser distorted by the strong lensing effect of the Bose-Einstein Condensate (BEC) from which it is outcoupled. We observe a transverse structure containing caustics that vary with the density within the residing BEC. Using WKB approximation, Fresnel-Kirchhoff integral formalism and ABCD matrices, we are able to describe analytically the atom laser propagation. This allows us to characterize the quality of the non-ideal atom laser beam by a generalized M$^2$ factor defined in analogy to photon lasers. Finally we measure this quality factor for different lensing effects.
△ Less
Submitted 30 November, 2005; v1 submitted 12 September, 2005;
originally announced September 2005.
-
Atom laser divergence
Authors:
Y. Le Coq,
J. H. Thywissen,
S. A. Rangwala,
F. Gerbier,
S. Richard,
G. Delannoy,
P. Bouyer,
A. Aspect
Abstract:
We measure the angular divergence of a quasi-continuous, rf-outcoupled, free-falling atom laser as a function of the outcoupling frequency. The data is compared to a Gaussian-beam model of laser propagation that generalizes the standard formalism of photonic lasers. Our treatment includes diffraction, magnetic lensing, and interaction between the atom laser and the condensate. We find that the d…
▽ More
We measure the angular divergence of a quasi-continuous, rf-outcoupled, free-falling atom laser as a function of the outcoupling frequency. The data is compared to a Gaussian-beam model of laser propagation that generalizes the standard formalism of photonic lasers. Our treatment includes diffraction, magnetic lensing, and interaction between the atom laser and the condensate. We find that the dominant source of divergence is the condensate-laser interaction.
△ Less
Submitted 7 September, 2001; v1 submitted 2 July, 2001;
originally announced July 2001.
-
Multi frequency evaporative cooling to BEC in a high magnetic field
Authors:
V. Boyer,
S. Murdoch,
Y. Le Coq,
G. Delannoy,
P. Bouyer,
A. Aspect
Abstract:
We demonstrate a way to circumvent the interruption of evaporative cooling observed at high bias field for $^{87}$Rb atoms trapped in the (F=2, m=+2) ground state. Our scheme uses a 3-frequencies-RF-knife achieved by mixing two RF frequencies. This compensates part of the non linearity of the Zeeman effect, allowing us to achieve BEC where standard 1-frequency-RF-knife evaporation method did not…
▽ More
We demonstrate a way to circumvent the interruption of evaporative cooling observed at high bias field for $^{87}$Rb atoms trapped in the (F=2, m=+2) ground state. Our scheme uses a 3-frequencies-RF-knife achieved by mixing two RF frequencies. This compensates part of the non linearity of the Zeeman effect, allowing us to achieve BEC where standard 1-frequency-RF-knife evaporation method did not work. We are able to get efficient evaporative cooling, provided that the residual detuning between the transition and the RF frequencies in our scheme is smaller than the power broadening of the RF transitions at the end of the evaporation ramp.
△ Less
Submitted 26 June, 2000; v1 submitted 5 May, 2000;
originally announced May 2000.
-
RF-induced evaporative cooling and BEC in a high magnetic field
Authors:
P. Bouyer,
V. Boyer,
S. G. Murdoch,
G. Delannoy,
Y. Le Coq,
A. Aspect,
M. Lecrivain
Abstract:
We present the design of our iron-core electromagnet for BEC, and how to solve the specific experimental problems raised by this technique. After presenting the experimental set-up, we address the interruption of runaway evaporative cooling when the Zeeman effect is not linear. We present the ways to circumvent this problem, use of multiple RF frequencies, sympathetic cooling and show some appli…
▽ More
We present the design of our iron-core electromagnet for BEC, and how to solve the specific experimental problems raised by this technique. After presenting the experimental set-up, we address the interruption of runaway evaporative cooling when the Zeeman effect is not linear. We present the ways to circumvent this problem, use of multiple RF frequencies, sympathetic cooling and show some applications of these high magnetic fields (cavity coupling, high confinement).
△ Less
Submitted 22 March, 2000;
originally announced March 2000.