-
Beam test results of a fully 3D-printed plastic scintillator particle detector prototype
Authors:
Botao Li,
Tim Weber,
Umut Kose,
Matthew Franks,
Johannes Wüthrich,
Xingyu Zhao,
Davide Sgalaberna,
Andrey Boyarintsev,
Tetiana Sibilieva,
Siddartha Berns,
Eric Boillat,
Albert De Roeck,
Till Dieminger,
Boris Grynyov,
Sylvain Hugon,
Carsten Jaeschke,
André Rubbia
Abstract:
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype fabricated by additive manufacturing, consisting of a 5 x 5 x 5 array of 1 cm3 plastic scintillator cubes, each optically isolated. This innovative approach eliminate…
▽ More
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype fabricated by additive manufacturing, consisting of a 5 x 5 x 5 array of 1 cm3 plastic scintillator cubes, each optically isolated. This innovative approach eliminates the need to construct complex monolithic geometries in a single operation and gets rid of the traditional time-consuming manufacturing and assembling processes. The prototype underwent performance characterization during a beam test at CERN's Proton-Synchrotron facility. Light yield, optical crosstalk, and light response uniformity, were evaluated. The prototype demonstrated a consistent light yield of approximately 27 photoelectrons (p.e.) per channel, similar to traditional cast scintillator detectors. Crosstalk between adjacent cubes averaged 4-5%, and light yield uniformity within individual cubes exhibited about 7% variation, indicating stability and reproducibility. These results underscore the potential of the novel additive manufacturing technique, for efficient and reliable production of high-granularity scintillator detectors.
△ Less
Submitted 4 February, 2025; v1 submitted 13 December, 2024;
originally announced December 2024.
-
AI-based particle track identification in scintillating fibres read out with imaging sensors
Authors:
Noemi Bührer,
Saúl Alonso-Monsalve,
Matthew Franks,
Till Dieminger,
Davide Sgalaberna
Abstract:
This paper presents the development and application of an AI-based method for particle track identification using scintillating fibres read out with imaging sensors. We propose a variational autoencoder (VAE) to efficiently filter and identify frames containing signal from the substantial data generated by SPAD array sensors. Our VAE model, trained on purely background frames, demonstrated a high…
▽ More
This paper presents the development and application of an AI-based method for particle track identification using scintillating fibres read out with imaging sensors. We propose a variational autoencoder (VAE) to efficiently filter and identify frames containing signal from the substantial data generated by SPAD array sensors. Our VAE model, trained on purely background frames, demonstrated a high capability to distinguish frames containing particle tracks from background noise. The performance of the VAE-based anomaly detection was validated with experimental data, demonstrating the method's ability to efficiently identify relevant events with rapid processing time, suggesting a solid prospect for deployment as a fast inference tool on hardware for real-time anomaly detection. This work highlights the potential of combining advanced sensor technology with machine learning techniques to enhance particle detection and tracking.
△ Less
Submitted 5 May, 2025; v1 submitted 14 October, 2024;
originally announced October 2024.
-
Additive manufacturing of a 3D-segmented plastic scintillator detector for tracking and calorimetry of elementary particles
Authors:
Tim Weber,
Andrey Boyarintsev,
Umut Kose,
Boato Li,
Davide Sgalaberna,
Tetiana Sibilieva,
Siddartha Berns,
Eric Boillat,
Albert De Roeck,
Till Dieminger,
Stephen Dolan,
Matthew Franks,
Boris Grynyov,
Sylvain Hugon,
Carsten Jaeschke,
André Rubbia
Abstract:
Plastic-scintillator detectors are devices used for the detection of elementary particles. They provide good particle identification with excellent time resolution, whilst being inexpensive due to the affordability of plastic materials. Particle tracking is achieved by segmenting the scintillator into smaller optically-isolated 3D granular sub-structures which require the integration of multiple t…
▽ More
Plastic-scintillator detectors are devices used for the detection of elementary particles. They provide good particle identification with excellent time resolution, whilst being inexpensive due to the affordability of plastic materials. Particle tracking is achieved by segmenting the scintillator into smaller optically-isolated 3D granular sub-structures which require the integration of multiple types of plastic materials as well as several thousands of tiny holes through a compact volume of several cubic meters. Future particle detectors necessitate larger volumes, possibly with even finer segmentation. However, manufacturing such geometries with current production strategies is challenging, as they involve time-consuming and costly fabrication processes, followed by the assembly of millions of individual parts. The difficulty in scaling up such a workflow can be addressed by additive manufacturing, enabling the construction of complex, monolithic geometries in a single operation. This article presents the fabrication of the first additive manufactured plastic scintillator detector, capable of 3D tracking elementary particles and measuring their stopping power. Its performance is comparable to the state of the art of plastic scintillator detectors. This work paves the way towards a new feasible, time and cost-effective process for the production of future plastic-based scintillator detectors, regardless their size and difficulty in geometry.
△ Less
Submitted 12 June, 2024; v1 submitted 7 December, 2023;
originally announced December 2023.
-
Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and $^{90}\mathrm{Sr}$
Authors:
J. Debevc,
M. Franks,
B. Hiti,
U. Kraemer,
G. Kramberger,
I. Mandić,
R. Marco-Hernández,
D. J. L. Nobels,
S. Powell,
J. Sonneveld,
H. Steininger,
C. Tsolanta,
E. Vilella,
C. Zhang
Abstract:
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage…
▽ More
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage. Timing performance was evaluated for the entire pixel matrix and with positional sensitivity within individual pixels as a function of the deposited charge. Time resolution obtained with TCT is seen to be uniform throughout the pixel's central region with approx. $220\,\mathrm{ps}$ at $12\,\mathrm{ke}^-$ of deposited charge, degrading at the edges and lower values of deposited charge. $^{90}\mathrm{Sr}$ measurements show a slightly worse time resolution as a result of delayed events coming from the peripheral areas of the pixel.
△ Less
Submitted 25 January, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
Demonstration of particle tracking with scintillating fibres read out by a SPAD array sensor and application as a neutrino active target
Authors:
Matthew Franks,
Till Dieminger,
Kodai Kaneyasu,
Davide Sgalaberna,
Claudio Bruschini,
Edoardo Charbon,
Umut Kose,
Botao Li,
Paul Mos,
Michael Wayne,
Tim Weber,
Jialin Wu
Abstract:
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres with a few hundred $μ$m diameter are used, either they are grouped together and coupled with a single SiPM, losing spatial resolution, or a very large number o…
▽ More
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres with a few hundred $μ$m diameter are used, either they are grouped together and coupled with a single SiPM, losing spatial resolution, or a very large number of electronic channels is required. In this article we propose and provide a first demonstration of a novel configuration which allows each individual scintillating fibre to be read out regardless of the size of its diameter, by imaging them with Single-Photon Avalanche Diode (SPAD) array sensors. Differently from SiPMs, SPAD array sensors provide single-photon detection with single-pixel spatial resolution. In addition, O(us) or faster coincidence of detected photons allows to obtain noise-free images. Such a concept can be particularly advantageous if adopted as a neutrino active target, where scintillating fibres alternated along orthogonal directions can provide isotropic, high-resolution tracking in a dense material and reconstruct the kinematics of low-momentum protons (down to 150 MeV/c), crucial for an accurate characterisation of the neutrino nucleus cross section. In this work the tracking capabilities of a bundle of scintillating fibres coupled to SwissSPAD2 is demonstrated. The impact of such detector configuration in GeV-neutrino experiments is studied with simulations and reported. Finally, future plans, including the development of a new SPAD array sensor optimised for neutrino detection, are discussed.
△ Less
Submitted 13 November, 2023; v1 submitted 6 September, 2023;
originally announced September 2023.
-
Optimal pricing for carbon dioxide removal under inter-regional leakage
Authors:
Max Franks,
Matthias Kalkuhl,
Kai Lessmann
Abstract:
Carbon dioxide removal (CDR) moves atmospheric carbon to geological or land-based sinks. In a first-best setting, the optimal use of CDR is achieved by a removal subsidy that equals the optimal carbon tax and marginal damages. We derive second-best policy rules for CDR subsidies and carbon taxes when no global carbon price exists but a national government implements a unilateral climate policy. We…
▽ More
Carbon dioxide removal (CDR) moves atmospheric carbon to geological or land-based sinks. In a first-best setting, the optimal use of CDR is achieved by a removal subsidy that equals the optimal carbon tax and marginal damages. We derive second-best policy rules for CDR subsidies and carbon taxes when no global carbon price exists but a national government implements a unilateral climate policy. We find that the optimal carbon tax differs from an optimal CDR subsidy because of carbon leakage and a balance of resource trade effect. First, the optimal removal subsidy tends to be larger than the carbon tax because of lower supply-side leakage on fossil resource markets. Second, net carbon exporters exacerbate this wedge to increase producer surplus of their carbon resource producers, implying even larger removal subsidies. Third, net carbon importers may set their removal subsidy even below their carbon tax when marginal environmental damages are small, to appropriate producer surplus from carbon exporters.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Initial recommendations for performing, benchmarking, and reporting single-cell proteomics experiments
Authors:
Laurent Gatto,
Ruedi Aebersold,
Juergen Cox,
Vadim Demichev,
Jason Derks,
Edward Emmott,
Alexander M. Franks,
Alexander R. Ivanov,
Ryan T. Kelly,
Luke Khoury,
Andrew Leduc,
Michael J. MacCoss,
Peter Nemes,
David H. Perlman,
Aleksandra A. Petelski,
Christopher M. Rose,
Erwin M. Schoof,
Jennifer Van Eyk,
Christophe Vanderaa,
John R. Yates III,
Nikolai Slavov
Abstract:
Analyzing proteins from single cells by tandem mass spectrometry (MS) has become technically feasible. While such analysis has the potential to accurately quantify thousands of proteins across thousands of single cells, the accuracy and reproducibility of the results may be undermined by numerous factors affecting experimental design, sample preparation, data acquisition, and data analysis. Broadl…
▽ More
Analyzing proteins from single cells by tandem mass spectrometry (MS) has become technically feasible. While such analysis has the potential to accurately quantify thousands of proteins across thousands of single cells, the accuracy and reproducibility of the results may be undermined by numerous factors affecting experimental design, sample preparation, data acquisition, and data analysis. Broadly accepted community guidelines and standardized metrics will enhance rigor, data quality, and alignment between laboratories. Here we propose best practices, quality controls, and data reporting recommendations to assist in the broad adoption of reliable quantitative workflows for single-cell proteomics.
△ Less
Submitted 12 September, 2022; v1 submitted 19 July, 2022;
originally announced July 2022.
-
Study of neutron irradiation effects in Depleted CMOS detector structures
Authors:
I. Mandić,
V. Cindro,
J. Debevc,
A. Gorišek,
B. Hiti,
G. Kramberger,
P. Skomina,
M. Zavrtanik,
M. Mikuž,
E. Vilella,
C. Zhang,
S. Powell,
M. Franks,
R. Marco-Hernandez,
H. Steininger
Abstract:
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$Ω$cm are presented. Samples were irradiated with reactor neutrons up to a fluence of 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Depletion depth was measured with Edge-TCT. Effective space charg…
▽ More
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$Ω$cm are presented. Samples were irradiated with reactor neutrons up to a fluence of 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Depletion depth was measured with Edge-TCT. Effective space charge concentration $N_{\mathrm{eff}}$ was estimated from the dependence of depletion depth on bias voltage and studied as a function of neutron fluence. Dependence of $N_{\mathrm{eff}}$ on fluence changes with initial acceptor concentration in agreement with other measurements with p-type silicon. Long term accelerated annealing study of $N_{\mathrm{eff}}$ and detector current up to 1280 minutes at 60$^\circ$C was made. It was found that $N_{\mathrm{eff}}$ and current in reverse biased detector behaves as expected for irradiated silicon.
△ Less
Submitted 15 February, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
Characterisation of analogue front end and time walk in CMOS active pixel sensor
Authors:
B. Hiti,
V. Cindro,
A. Gorišek,
M. Franks,
R. Marco-Hernández,
G. Kramberger,
I. Mandić,
M. Mikuž,
S. Powell,
H. Steininger,
E. Vilella,
M. Zavrtanik,
C. Zhang
Abstract:
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2. Threshold, noise and calibration of the analogue front end were determined with external charge injection. A spatially sensitive measurement of collected charge a…
▽ More
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2. Threshold, noise and calibration of the analogue front end were determined with external charge injection. A spatially sensitive measurement of collected charge and time walk was carried out with Edge-TCT, showing a uniform charge collection and output delay in pixel centre. On pixel edges charge sharing was observed due to finite beam width resulting in smaller signals and larger output delay. Time walk below 25 ns was observed for charge above 2000 electrons at a threshold above the noise level. Time walk measurement with external charge injection yielded identical results.
△ Less
Submitted 23 November, 2021; v1 submitted 11 October, 2021;
originally announced October 2021.
-
Non-standard conditionally specified models for non-ignorable missing data
Authors:
Alexander M Franks,
Edoardo M Airoldi,
Donald B Rubin
Abstract:
Data analyses typically rely upon assumptions about missingness mechanisms that lead to observed versus missing data. When the data are missing not at random, direct assumptions about the missingness mechanism, and indirect assumptions about the distributions of observed and missing data, are typically untestable. We explore an approach, where the joint distribution of observed data and missing da…
▽ More
Data analyses typically rely upon assumptions about missingness mechanisms that lead to observed versus missing data. When the data are missing not at random, direct assumptions about the missingness mechanism, and indirect assumptions about the distributions of observed and missing data, are typically untestable. We explore an approach, where the joint distribution of observed data and missing data is specified through non-standard conditional distributions. In this formulation, which traces back to a factorization of the joint distribution, apparently proposed by J.W. Tukey, the modeling assumptions about the conditional factors are either testable or are designed to allow the incorporation of substantive knowledge about the problem at hand, thereby offering a possibly realistic portrayal of the data, both missing and observed. We apply Tukey's conditional representation to exponential family models, and we propose a computationally tractable inferential strategy for this class of models. We illustrate the utility of this approach using high-throughput biological data with missing data that are not missing at random.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.