Title:A Sensorless Control System for an Implantable Heart Pump using a Real-time Deep Convolutional Neural Network

Authors:Masoud Fetanat, Michael Stevens, Christopher Hayward, Nigel H. Lovell
View a PDF of the paper titled A Sensorless Control System for an Implantable Heart Pump using a Real-time Deep Convolutional Neural Network, by Masoud Fetanat and 2 other authors
View PDF
Abstract:Left ventricular assist devices (LVADs) are mechanical pumps, which can be used to support heart failure (HF) patients as bridge to transplant and destination therapy. To automatically adjust the LVAD speed, a physiological control system needs to be designed to respond to variations of patient hemodynamics across a variety of clinical scenarios. These control systems require pressure feedback signals from the cardiovascular system. However, there are no suitable long-term implantable sensors available. In this study, a novel real-time deep convolutional neural network (CNN) for estimation of preload based on the LVAD flow was proposed. A new sensorless adaptive physiological control system for an LVAD pump was developed using the full dynamic form of model free adaptive control (FFDL-MFAC) and the proposed preload estimator to maintain the patient conditions in safe physiological ranges. The CNN model for preload estimation was trained and evaluated through 10-fold cross validation on 100 different patient conditions and the proposed sensorless control system was assessed on a new testing set of 30 different patient conditions across six different patient scenarios. The proposed preload estimator was extremely accurate with a correlation coefficient of 0.97, root mean squared error of 0.84 mmHg, reproducibility coefficient of 1.56 mmHg, coefficient of variation of 14.44 %, and bias of 0.29 mmHg for the testing dataset. The results also indicate that the proposed sensorless physiological controller works similarly to the preload-based physiological control system for LVAD using measured preload to prevent ventricular suction and pulmonary congestion. This study shows that the LVADs can respond appropriately to changing patient states and physiological demands without the need for additional pressure or flow measurements.
Subjects: Systems and Control (eess.SY); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)
Cite as: arXiv:2105.00875 [eess.SY]
  (or arXiv:2105.00875v1 [eess.SY] for this version)
  https://doi.org/10.48550/arXiv.2105.00875
arXiv-issued DOI via DataCite
Journal reference: IEEE Transactions on Biomedical Engineering, 2021
Related DOI: https://doi.org/10.1109/TBME.2021.3061405
DOI(s) linking to related resources

Submission history

From: Masoud Fetanat [view email]
[v1] Fri, 30 Apr 2021 05:12:09 UTC (835 KB)
Full-text links:

Access Paper:

    View a PDF of the paper titled A Sensorless Control System for an Implantable Heart Pump using a Real-time Deep Convolutional Neural Network, by Masoud Fetanat and 2 other authors
  • View PDF
  • Other Formats
license icon view license
Current browse context:
eess.SY
< prev   |   next >
new | recent | 2021-05
Change to browse by:
cs
cs.AI
cs.LG
cs.SY
eess

References & Citations

  • NASA ADS
  • Google Scholar
  • Semantic Scholar
a export BibTeX citation Loading...

BibTeX formatted citation

×
Data provided by:

Bookmark

BibSonomy logo Reddit logo

Bibliographic and Citation Tools

Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)

Code, Data and Media Associated with this Article

alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)

Demos

Replicate (What is Replicate?)
Hugging Face Spaces (What is Spaces?)
TXYZ.AI (What is TXYZ.AI?)

Recommenders and Search Tools

Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
  • Author
  • Venue
  • Institution
  • Topic

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)
  • About
  • Help
  • contact arXivClick here to contact arXiv Contact
  • subscribe to arXiv mailingsClick here to subscribe Subscribe
  • Copyright
  • Privacy Policy
  • Web Accessibility Assistance
  • arXiv Operational Status
    Get status notifications via email or slack