Skip to main content
Cornell University
We gratefully acknowledge support from the Simons Foundation, member institutions, and all contributors. Donate
arxiv logo > physics > arXiv:2008.02428

Help | Advanced Search

arXiv logo
Cornell University Logo

quick links

  • Login
  • Help Pages
  • About

Physics > Medical Physics

arXiv:2008.02428 (physics)
[Submitted on 6 Aug 2020 (v1), last revised 10 Sep 2020 (this version, v2)]

Title:Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy

Authors:Yanqi Huang, Kai Yang, Youfang Lai, Huan Liu, Chenyang Shen, Yuncheng Zhong, Yiping Shao, Xinhua Li, Bob Liu, Xun Jia
View a PDF of the paper titled Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy, by Yanqi Huang and 9 other authors
View PDF
Abstract:Motion management is a critical component of image guidance radiotherapy for lung cancer. We previously proposed a scheme using kV scattered x-ray photons for marker-less real-time image guidance in lung cancer radiotherapy. This study reports our recently progress using the photon counting detection technique to demonstrate potential feasibility of this method and using Monte Carlo (MC) simulations and ray-tracing calculations to characterize the performance. In our scheme, a thin slice of x-ray beam was directed to the target and we measured the outgoing scattered photons using a photon counting detector with a parallel-hole collimator to establish the correspondence between detector pixels and scatter positions. Image corrections of geometry, beam attenuation and scattering angle were performed to convert the raw image to the actual image of Compton attenuation coefficient. We set up a MC simulation system using an in-house developed GPU-based MC package modeling the image formation process. We also performed ray-tracing calculations to investigate the impacts of imaging system geometry on resulting image resolution. The experiment demonstrated feasibility of using a photon counting detector to measure scattered x-ray photons and generate the proposed scattered x-ray image. After correction, x-ray scattering image intensity and Compton scattering attenuation coefficient were linearly related, with R2=0.91. Contrast to Noise Ratios of different objects were improved and the values in experimental results and MC simulation results agreed with each other. Ray-tracing calculations revealed the dependence of image resolution on imaging geometry. The image resolution increases with reduced source to object distance and increased collimator height. The study demonstrated potential feasibility of using scattered x-ray imaging as a real-time image guidance method in radiation therapy.
Comments: 16 pages, 10 figures
Subjects: Medical Physics (physics.med-ph)
Cite as: arXiv:2008.02428 [physics.med-ph]
  (or arXiv:2008.02428v2 [physics.med-ph] for this version)
  https://doi.org/10.48550/arXiv.2008.02428
arXiv-issued DOI via DataCite

Submission history

From: Xun Jia [view email]
[v1] Thu, 6 Aug 2020 02:11:26 UTC (3,376 KB)
[v2] Thu, 10 Sep 2020 00:57:20 UTC (3,424 KB)
Full-text links:

Access Paper:

    View a PDF of the paper titled Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy, by Yanqi Huang and 9 other authors
  • View PDF
  • Other Formats
view license
Current browse context:
physics.med-ph
< prev   |   next >
new | recent | 2020-08
Change to browse by:
physics

References & Citations

  • NASA ADS
  • Google Scholar
  • Semantic Scholar
a export BibTeX citation Loading...

BibTeX formatted citation

×
Data provided by:

Bookmark

BibSonomy logo Reddit logo

Bibliographic and Citation Tools

Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)

Code, Data and Media Associated with this Article

alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)

Demos

Replicate (What is Replicate?)
Hugging Face Spaces (What is Spaces?)
TXYZ.AI (What is TXYZ.AI?)

Recommenders and Search Tools

Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
  • Author
  • Venue
  • Institution
  • Topic

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Which authors of this paper are endorsers? | Disable MathJax (What is MathJax?)
  • About
  • Help
  • contact arXivClick here to contact arXiv Contact
  • subscribe to arXiv mailingsClick here to subscribe Subscribe
  • Copyright
  • Privacy Policy
  • Web Accessibility Assistance
  • arXiv Operational Status
    Get status notifications via email or slack