Impact of Record-Linkage Errors in Covid-19 Vaccine-Safety Analyses using German Health-Care Data: A Simulation Study
Authors:
Robin Denz,
Katharina Meiszl,
Peter Ihle,
Doris Oberle,
Ursula Drechsel-Bäuerle,
Katrin Scholz,
Ingo Meyer,
Nina Timmesfeld
Abstract:
With unprecedented speed, 192,248,678 doses of Covid-19 vaccines were administered in Germany by July 11, 2023 to combat the pandemic. Limitations of clinical trials imply that the safety profile of these vaccines is not fully known before marketing. However, routine health-care data can help address these issues. Despite the high proportion of insured people, the analysis of vaccination-related d…
▽ More
With unprecedented speed, 192,248,678 doses of Covid-19 vaccines were administered in Germany by July 11, 2023 to combat the pandemic. Limitations of clinical trials imply that the safety profile of these vaccines is not fully known before marketing. However, routine health-care data can help address these issues. Despite the high proportion of insured people, the analysis of vaccination-related data is challenging in Germany. Generally, the Covid-19 vaccination status and other health-care data are stored in separate databases, without persistent and database-independent person identifiers. Error-prone record-linkage techniques must be used to merge these databases. Our aim was to quantify the impact of record-linkage errors on the power and bias of different analysis methods designed to assess Covid-19 vaccine safety when using German health-care data with a Monte-Carlo simulation study. We used a discrete-time simulation and empirical data to generate realistic data with varying amounts of record-linkage errors. Afterwards, we analysed this data using a Cox model and the self-controlled case series (SCCS) method. Realistic proportions of random linkage errors only had little effect on the power of either method. The SCCS method produced unbiased results even with a high percentage of linkage errors, while the Cox model underestimated the true effect.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Improved inter-scanner MS lesion segmentation by adversarial training on longitudinal data
Authors:
Mattias Billast,
Maria Ines Meyer,
Diana M. Sima,
David Robben
Abstract:
The evaluation of white matter lesion progression is an important biomarker in the follow-up of MS patients and plays a crucial role when deciding the course of treatment. Current automated lesion segmentation algorithms are susceptible to variability in image characteristics related to MRI scanner or protocol differences. We propose a model that improves the consistency of MS lesion segmentations…
▽ More
The evaluation of white matter lesion progression is an important biomarker in the follow-up of MS patients and plays a crucial role when deciding the course of treatment. Current automated lesion segmentation algorithms are susceptible to variability in image characteristics related to MRI scanner or protocol differences. We propose a model that improves the consistency of MS lesion segmentations in inter-scanner studies. First, we train a CNN base model to approximate the performance of icobrain, an FDA-approved clinically available lesion segmentation software. A discriminator model is then trained to predict if two lesion segmentations are based on scans acquired using the same scanner type or not, achieving a 78% accuracy in this task. Finally, the base model and the discriminator are trained adversarially on multi-scanner longitudinal data to improve the inter-scanner consistency of the base model. The performance of the models is evaluated on an unseen dataset containing manual delineations. The inter-scanner variability is evaluated on test-retest data, where the adversarial network produces improved results over the base model and the FDA-approved solution.
△ Less
Submitted 27 October, 2020; v1 submitted 3 February, 2020;
originally announced February 2020.
-
Relevance Vector Machines for harmonization of MRI brain volumes using image descriptors
Authors:
Maria Ines Meyer,
Ezequiel de la Rosa,
Koen Van Leemput,
Diana M. Sima
Abstract:
With the increased need for multi-center magnetic resonance imaging studies, problems arise related to differences in hardware and software between centers. Namely, current algorithms for brain volume quantification are unreliable for the longitudinal assessment of volume changes in this type of setting. Currently most methods attempt to decrease this issue by regressing the scanner- and/or center…
▽ More
With the increased need for multi-center magnetic resonance imaging studies, problems arise related to differences in hardware and software between centers. Namely, current algorithms for brain volume quantification are unreliable for the longitudinal assessment of volume changes in this type of setting. Currently most methods attempt to decrease this issue by regressing the scanner- and/or center-effects from the original data. In this work, we explore a novel approach to harmonize brain volume measurements by using only image descriptors. First, we explore the relationships between volumes and image descriptors. Then, we train a Relevance Vector Machine (RVM) model over a large multi-site dataset of healthy subjects to perform volume harmonization. Finally, we validate the method over two different datasets: i) a subset of unseen healthy controls; and ii) a test-retest dataset of multiple sclerosis (MS) patients. The method decreases scanner and center variability while preserving measurements that did not require correction in MS patient data. We show that image descriptors can be used as input to a machine learning algorithm to improve the reliability of longitudinal volumetric studies.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Towards Adversarial Retinal Image Synthesis
Authors:
Pedro Costa,
Adrian Galdran,
Maria Inês Meyer,
Michael David Abràmoff,
Meindert Niemeijer,
Ana Maria Mendonça,
Aurélio Campilho
Abstract:
Synthesizing images of the eye fundus is a challenging task that has been previously approached by formulating complex models of the anatomy of the eye. New images can then be generated by sampling a suitable parameter space. In this work, we propose a method that learns to synthesize eye fundus images directly from data. For that, we pair true eye fundus images with their respective vessel trees,…
▽ More
Synthesizing images of the eye fundus is a challenging task that has been previously approached by formulating complex models of the anatomy of the eye. New images can then be generated by sampling a suitable parameter space. In this work, we propose a method that learns to synthesize eye fundus images directly from data. For that, we pair true eye fundus images with their respective vessel trees, by means of a vessel segmentation technique. These pairs are then used to learn a mapping from a binary vessel tree to a new retinal image. For this purpose, we use a recent image-to-image translation technique, based on the idea of adversarial learning. Experimental results show that the original and the generated images are visually different in terms of their global appearance, in spite of sharing the same vessel tree. Additionally, a quantitative quality analysis of the synthetic retinal images confirms that the produced images retain a high proportion of the true image set quality.
△ Less
Submitted 31 January, 2017;
originally announced January 2017.