Measurement Error Correction in Particle Tracking Microrheology
Authors:
Yun Ling,
Martin Lysy,
Ian Seim,
Jay M. Newby,
David B. Hill,
Jeremy Cribb,
M. Gregory Forest
Abstract:
In diverse biological applications, particle tracking of passive microscopic species has become the experimental measurement of choice -- when either the materials are of limited volume, or so soft as to deform uncontrollably when manipulated by traditional instruments. In a wide range of particle tracking experiments, a ubiquitous finding is that the mean squared displacement (MSD) of particle po…
▽ More
In diverse biological applications, particle tracking of passive microscopic species has become the experimental measurement of choice -- when either the materials are of limited volume, or so soft as to deform uncontrollably when manipulated by traditional instruments. In a wide range of particle tracking experiments, a ubiquitous finding is that the mean squared displacement (MSD) of particle positions exhibits a power-law signature, the parameters of which reveal valuable information about the viscous and elastic properties of various biomaterials. However, MSD measurements are typically contaminated by complex and interacting sources of instrumental noise. As these often affect the high-frequency bandwidth to which MSD estimates are particularly sensitive, inadequate error correction can lead to severe bias in power law estimation and thereby, the inferred viscoelastic properties. In this article, we propose a novel strategy to filter high-frequency noise from particle tracking measurements. Our filters are shown theoretically to cover a broad spectrum of high-frequency noises, and lead to a parametric estimator of MSD power-law coefficients for which an efficient computational implementation is presented. Based on numerous analyses of experimental and simulated data, results suggest our methods perform very well compared to other denoising procedures.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Maximum Likelihood Estimation for Single Particle, Passive Microrheology Data with Drift
Authors:
John W. R. Mellnik,
Martin Lysy,
Paula A. Vasquez,
Natesh S. Pillai,
David B. Hill,
Jeremy Crib,
Scott A. McKinley,
M. Gregory Forest
Abstract:
Volume limitations and low yield thresholds of biological fluids have led to widespread use of passive microparticle rheology. The mean-squared-displacement (MSD) statistics of bead position time series (bead paths) are either applied directly to determine the creep compliance [Xu et al (1998)] or transformed to determine dynamic storage and loss moduli [Mason & Weitz (1995)]. A prevalent hurdle a…
▽ More
Volume limitations and low yield thresholds of biological fluids have led to widespread use of passive microparticle rheology. The mean-squared-displacement (MSD) statistics of bead position time series (bead paths) are either applied directly to determine the creep compliance [Xu et al (1998)] or transformed to determine dynamic storage and loss moduli [Mason & Weitz (1995)]. A prevalent hurdle arises when there is a non-diffusive experimental drift in the data. Commensurate with the magnitude of drift relative to diffusive mobility, quantified by a Péclet number, the MSD statistics are distorted, and thus the path data must be "corrected" for drift. The standard approach is to estimate and subtract the drift from particle paths, and then calculate MSD statistics. We present an alternative, parametric approach using maximum likelihood estimation that simultaneously fits drift and diffusive model parameters from the path data; the MSD statistics (and consequently the compliance and dynamic moduli) then follow directly from the best-fit model. We illustrate and compare both methods on simulated path data over a range of Péclet numbers, where exact answers are known. We choose fractional Brownian motion as the numerical model because it affords tunable, sub-diffusive MSD statistics consistent with typical 30 second long, experimental observations of microbeads in several biological fluids. Finally, we apply and compare both methods on data from human bronchial epithelial cell culture mucus.
△ Less
Submitted 21 February, 2016; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Model comparison and assessment for single particle tracking in biological fluids
Authors:
Martin Lysy,
Natesh S. Pillai,
David B. Hill,
M. Gregory Forest,
John Mellnik,
Paula Vasquez,
Scott A. McKinley
Abstract:
State-of-the-art techniques in passive particle-tracking microscopy provide high-resolution path trajectories of diverse foreign particles in biological fluids. For particles on the order of 1 micron diameter, these paths are generally inconsistent with simple Brownian motion. Yet, despite an abundance of data confirming these findings and their wide-ranging scientific implications, stochastic mod…
▽ More
State-of-the-art techniques in passive particle-tracking microscopy provide high-resolution path trajectories of diverse foreign particles in biological fluids. For particles on the order of 1 micron diameter, these paths are generally inconsistent with simple Brownian motion. Yet, despite an abundance of data confirming these findings and their wide-ranging scientific implications, stochastic modeling of the complex particle motion has received comparatively little attention. Even among posited models, there is virtually no literature on likelihood-based inference, model comparisons, and other quantitative assessments. In this article, we develop a rigorous and computationally efficient Bayesian methodology to address this gap. We analyze two of the most prevalent candidate models for 30 second paths of 1 micron diameter tracer particles in human lung mucus: fractional Brownian motion (fBM) and a Generalized Langevin Equation (GLE) consistent with viscoelastic theory. Our model comparisons distinctly favor GLE over fBM, with the former describing the data remarkably well up to the timescales for which we have reliable information.
△ Less
Submitted 29 November, 2015; v1 submitted 22 July, 2014;
originally announced July 2014.