-
Compressive quantum waveform estimation
Authors:
Alex Tritt,
Joshua Morris,
Christopher C. Bounds,
Hamish A. M. Taylor,
James Saunderson,
L. D. Turner
Abstract:
Quantum waveform estimation, in which quantum sensors sample entire time series, promises to revolutionize the sensing of weak and stochastic signals, such as the biomagnetic impulses emitted by firing neurons. For long duration signals with rapid transients, regular quantum sampling becomes prohibitively resource intensive as it demands many measurements with distinct control and readout. In this…
▽ More
Quantum waveform estimation, in which quantum sensors sample entire time series, promises to revolutionize the sensing of weak and stochastic signals, such as the biomagnetic impulses emitted by firing neurons. For long duration signals with rapid transients, regular quantum sampling becomes prohibitively resource intensive as it demands many measurements with distinct control and readout. In this Manuscript, we demonstrate how careful choice of quantum measurements, along with the modern mathematics of compressive sensing, achieves quantum waveform estimation of sparse signals in a number of measurements far below the Nyquist requirement. We sense synthesized neural-like magnetic signals with radiofrequency-dressed ultracold atoms, retrieving successful waveform estimates with as few measurements as compressive theoretical bounds guarantee.
△ Less
Submitted 15 December, 2023; v1 submitted 24 October, 2023;
originally announced October 2023.
-
Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT/rHz
Authors:
Hamish A. M. Taylor,
Christopher C. Bounds,
Alex Tritt,
L. D. Turner
Abstract:
Cold atom magnetometers exploit a dense ensemble of quanta with long coherence times to realise leading sensitivity on the micrometer scale. Configured as a Ramsey interferometer, a cold atom sensor can approach atom shot-noise limited precision but suffers from fringe ambiguity, producing gross errors when the field falls outside a narrow predefined range. We describe how Hilbert-demodulated opti…
▽ More
Cold atom magnetometers exploit a dense ensemble of quanta with long coherence times to realise leading sensitivity on the micrometer scale. Configured as a Ramsey interferometer, a cold atom sensor can approach atom shot-noise limited precision but suffers from fringe ambiguity, producing gross errors when the field falls outside a narrow predefined range. We describe how Hilbert-demodulated optical magnetometry can be realised on cold atom sensors to provide field measurements both precise and unambiguous. Continuous reconstruction of the Larmor phase allows us to determine the dc magnetic field unambiguously in an unshielded environment, as well as measure ac variation of the field, in a single shot. The ac measurement allows us to characterize, and then neutralise, line-synchronous magnetic interference, extending reconstruction times. Using $1.6 \times 10^6$ $^{87}$Rb atoms in a volume of $(68 \,\mathrm{μm})^3$, we measure a test field to be $ 86.0121261(4) \; \mathrm{μT}$ in a single shot, achieving dc sensitivity of 380 fT in a duration of 1000 ms. Our results demonstrate that Hilbert-demodulated optical readout yields metrologically-significant sensitivity without the fringe ambiguity inherent to Ramsey interferometry.
△ Less
Submitted 19 June, 2024; v1 submitted 21 September, 2023;
originally announced September 2023.
-
Quantum spectral analysis by continuous measurement of Landau-Zener transitions
Authors:
Christopher C. Bounds,
Josh P. Duff,
Alex Tritt,
Hamish A. M. Taylor,
George X. Coe,
Sam J. White,
L. D. Turner
Abstract:
We demonstrate the simultaneous estimation of signal frequency and amplitude by a single quantum sensor in a single experimental shot. Sweeping the qubit splitting linearly across a span of frequencies induces a non-adiabatic Landau-Zener transition as the qubit crosses resonance. The signal frequency determines the time of the transition, and the amplitude its extent. Continuous weak measurement…
▽ More
We demonstrate the simultaneous estimation of signal frequency and amplitude by a single quantum sensor in a single experimental shot. Sweeping the qubit splitting linearly across a span of frequencies induces a non-adiabatic Landau-Zener transition as the qubit crosses resonance. The signal frequency determines the time of the transition, and the amplitude its extent. Continuous weak measurement of this unitary evolution informs a parameter estimator retrieving precision measurements of frequency and amplitude. Implemented on radiofrequency-dressed ultracold atoms read out by a Faraday spin-light interface, we sense a magnetic signal with $20~\text{pT}$ precision in amplitude, and near-transform-limited precision in frequency, in a single $300~\text{ms}$ sweep from $7$ to $13~\text{kHz}$. The protocol realizes a swept-sine quantum spectrum analyzer, potentially sensing hundreds or thousands of channels with a single quantum sensor.
△ Less
Submitted 7 December, 2023; v1 submitted 2 June, 2023;
originally announced June 2023.
-
Spinsim: a GPU optimized python package for simulating spin-half and spin-one quantum systems
Authors:
Alex Tritt,
Joshua Morris,
Joel Hochstetter,
R. P. Anderson,
James Saunderson,
L. D. Turner
Abstract:
The Spinsim python package simulates spin-half and spin-one quantum mechanical systems following a time dependent Shroedinger equation. It makes use of numba.cuda, which is an LLVM (Low Level Virtual Machine) compiler for Nvidia Cuda compatible systems using GPU parallelization. Along with other optimizations, this allows for speed improvements from 3 to 4 orders of magnitude while staying just as…
▽ More
The Spinsim python package simulates spin-half and spin-one quantum mechanical systems following a time dependent Shroedinger equation. It makes use of numba.cuda, which is an LLVM (Low Level Virtual Machine) compiler for Nvidia Cuda compatible systems using GPU parallelization. Along with other optimizations, this allows for speed improvements from 3 to 4 orders of magnitude while staying just as accurate, compared to industry standard packages. It is available for installation on PyPI, and the source code is available on github. The initial use-case for the Spinsim will be to simulate quantum sensing-based ultracold atom experiments for the Monash University School of Physics \& Astronomy spinor Bose-Einstein condensate (spinor BEC) lab, but we anticipate it will be useful in simulating any range of spin-half or spin-one quantum systems with time dependent Hamiltonians that cannot be solved analytically. These appear in the fields of nuclear magnetic resonance (NMR), nuclear quadrupole resonance (NQR) and magnetic resonance imaging (MRI) experiments and quantum sensing, and with the spin-one systems of nitrogen vacancy centres (NVCs), ultracold atoms, and BECs.
△ Less
Submitted 12 April, 2022;
originally announced April 2022.
-
Continuously observing a dynamically decoupled spin-1 quantum gas
Authors:
R. P. Anderson,
M. J. Kewming,
L. D. Turner
Abstract:
We continuously observe dynamical decoupling in a spin-1 quantum gas using a weak optical measurement of spin precession. Continuous dynamical decoupling aims to dramatically modify the character and energy spectrum of spin states to render them insensitive to parasitic fluctuations. Continuous observation measures this new spectrum in a single-preparation of the quantum gas. The measured time-ser…
▽ More
We continuously observe dynamical decoupling in a spin-1 quantum gas using a weak optical measurement of spin precession. Continuous dynamical decoupling aims to dramatically modify the character and energy spectrum of spin states to render them insensitive to parasitic fluctuations. Continuous observation measures this new spectrum in a single-preparation of the quantum gas. The measured time-series contains seven tones, which spectrogram analysis parses as splittings, coherences, and coupling strengths between the decoupled states in real-time. With this we locate a regime where a transition between two states is decoupled from magnetic field instabilities up to fourth order, complementary to the parallel work at higher fields by Trypogeorgos et al. (arXiv:1706.07876). The decoupled microscale quantum gas offers magnetic sensitivity in a tunable band, persistent over many milliseconds: the length scales, frequencies, and durations relevant to many applications, including sensing biomagnetic phenomena such as neural spike trains.
△ Less
Submitted 26 June, 2017; v1 submitted 26 June, 2017;
originally announced June 2017.
-
Magic-wavelength Faraday probe measures spin continuously and without light shifts
Authors:
M. Jasperse,
M. J. Kewming,
S. N. Fischer,
P. Pakkiam,
R. P. Anderson,
L. D. Turner
Abstract:
We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date focusing bright far-off-resonance probes onto quantum gases has proved invasive, due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wav…
▽ More
We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date focusing bright far-off-resonance probes onto quantum gases has proved invasive, due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of $^{87}$Rb cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally-invasive spin probe we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 μG accuracy every 5 ms; or equivalently makes > 200 successive measurements each at $10\,\mathrm{pT/\sqrt{Hz}}$ sensitivity.
△ Less
Submitted 31 May, 2017;
originally announced May 2017.
-
Measurement and extinction of vector light shifts using interferometry of spinor condensates
Authors:
A. A. Wood,
L. D. Turner,
R. P. Anderson
Abstract:
We use differential Ramsey interferometry of ultracold atoms to characterize the vector light shift (VLS) from a far-off resonance optical dipole trap at $λ= 1064\,\mathrm{nm}$. The VLS manifests as a `fictitious' magnetic field, which we perceive as a change in the Larmor frequency of two spinor condensates exposed to different intensities of elliptically polarized light. We use our measurement s…
▽ More
We use differential Ramsey interferometry of ultracold atoms to characterize the vector light shift (VLS) from a far-off resonance optical dipole trap at $λ= 1064\,\mathrm{nm}$. The VLS manifests as a `fictitious' magnetic field, which we perceive as a change in the Larmor frequency of two spinor condensates exposed to different intensities of elliptically polarized light. We use our measurement scheme to diagnose the light-induced magnetic field and suppress it to $2.1(8)\times10^{-4}$ of its maximum value, by making the trapping light linearly polarized with a quarter-wave plate in each beam. Our sensitive measurement of the VLS-induced field demonstrates high-precision, in-vacuo interferometric polarimetry of dipole trapping light and can be adapted to measure vector shifts from other lasers, advancing the application of optically trapped atoms to precision metrology.
△ Less
Submitted 20 November, 2016; v1 submitted 23 July, 2016;
originally announced July 2016.
-
A Monte Carlo wavefunction method for semiclassical simulations of spin-position entanglement
Authors:
C. J. Billington,
C. J. Watkins,
R. P. Anderson,
L. D. Turner
Abstract:
We present a Monte Carlo wavefunction method for semiclassically modeling spin-$\frac12$ systems in a magnetic field gradient in one dimension. Our model resolves the conflict of determining what classical force an atom should be subjected to when it is in an arbitrary superposition of internal states. Spatial degrees of freedom are considered to be an environment, entanglement with which decohere…
▽ More
We present a Monte Carlo wavefunction method for semiclassically modeling spin-$\frac12$ systems in a magnetic field gradient in one dimension. Our model resolves the conflict of determining what classical force an atom should be subjected to when it is in an arbitrary superposition of internal states. Spatial degrees of freedom are considered to be an environment, entanglement with which decoheres the internal states. Atoms follow classical trajectories through space, punctuated by probabilistic jumps between spin states.
We modify the conventional Monte Carlo wavefunction method to jump between states when population transfer occurs, rather than when population is later discarded via exponential decay. This results in a spinor wavefunction that is continuous in time, and allows us to model the classical particle trajectories (evolution of the environment variables) more accurately. The model is not computationally demanding and it agrees well with simulations of the full spatial wavefunction of an atom.
△ Less
Submitted 23 February, 2015;
originally announced February 2015.
-
Precise wavefunction engineering with magnetic resonance
Authors:
P. B. Wigley,
L. M. Starkey,
S. S. Szigeti,
M. Jasperse,
J. J. Hope,
L. D. Turner,
R. P. Anderson
Abstract:
Controlling quantum fluids at their fundamental length scale will yield superlative quantum simulators, precision sensors, and spintronic devices. This scale is typically below the optical diffraction limit, precluding precise wavefunction engineering using optical potentials alone. We present a protocol to rapidly control the phase and density of a quantum fluid down to the healing length scale u…
▽ More
Controlling quantum fluids at their fundamental length scale will yield superlative quantum simulators, precision sensors, and spintronic devices. This scale is typically below the optical diffraction limit, precluding precise wavefunction engineering using optical potentials alone. We present a protocol to rapidly control the phase and density of a quantum fluid down to the healing length scale using strong time-dependent coupling between internal states of the fluid in a magnetic field gradient. We demonstrate this protocol by simulating the creation of a single stationary soliton and double soliton states in a Bose-Einstein condensate with control over the individual soliton positions and trajectories, using experimentally feasible parameters. Such states are yet to be realized experimentally, and are a path towards engineering soliton gases and exotic topological excitations.
△ Less
Submitted 10 July, 2017; v1 submitted 21 December, 2014;
originally announced December 2014.
-
Magnetic tensor gradiometry using Ramsey interferometry of spinor condensates
Authors:
A. A. Wood,
L. M. Bennie,
A. Duong,
M. Jasperse,
L. D. Turner,
R. P. Anderson
Abstract:
We have realized a magnetic tensor gradiometer by interferometrically measuring the relative phase between two spatially separated Bose-Einstein condensates (BECs). We perform simultaneous Ramsey interferometry of the proximate $^{87}$Rb spin-1 condensates in freefall and infer their relative Larmor phase -- and thus the differential magnetic field strength -- with a common-mode phase noise suppre…
▽ More
We have realized a magnetic tensor gradiometer by interferometrically measuring the relative phase between two spatially separated Bose-Einstein condensates (BECs). We perform simultaneous Ramsey interferometry of the proximate $^{87}$Rb spin-1 condensates in freefall and infer their relative Larmor phase -- and thus the differential magnetic field strength -- with a common-mode phase noise suppression exceeding $50\,\mathrm{dB}$. By appropriately biasing the magnetic field and separating the BECs along orthogonal directions, we measure the magnetic field gradient tensor of ambient and applied magnetic fields with a nominal precision of $30\,\mathrm{μG\,cm^{-1}}$ and a sensor volume of $2\times10^{-5}\,\mathrm{mm}^3$. We predict a spin-projection noise limited magnetic energy resolution of order $\hbar$ for typical Zeeman coherence times of trapped condensates with this scheme, even with the low measurement duty cycle inherent to BEC experiments.
△ Less
Submitted 18 May, 2015; v1 submitted 5 August, 2014;
originally announced August 2014.
-
A scripted control system for autonomous hardware timed experiments
Authors:
P. T. Starkey,
C. J. Billington,
S. P. Johnstone,
M. Jasperse,
K. Helmerson,
L. D. Turner,
R. P. Anderson
Abstract:
We present the labscript suite, an open-source experiment control system for automating shot-based experiments and their analysis. Experiments are composed as Python code, which is used to produce low-level hardware instructions. They are queued up and executed on the hardware in real time, synchronized by a pseudoclock. Experiment parameters are manipulated graphically, and analysis routines are…
▽ More
We present the labscript suite, an open-source experiment control system for automating shot-based experiments and their analysis. Experiments are composed as Python code, which is used to produce low-level hardware instructions. They are queued up and executed on the hardware in real time, synchronized by a pseudoclock. Experiment parameters are manipulated graphically, and analysis routines are run as new data is acquired. With this system, we can easily automate exploration of parameter spaces, including closed-loop optimization.
△ Less
Submitted 21 August, 2013; v1 submitted 28 February, 2013;
originally announced March 2013.
-
Precision atomic gravimeter based on Bragg diffraction
Authors:
P. A. Altin,
M. T. Johnsson,
V. Negnevitsky,
G. R. Dennis,
R. P. Anderson,
J. E. Debs,
S. S. Szigeti,
K. S. Hardman,
S. Bennetts,
G. D. McDonald,
L. D. Turner,
J. D. Close,
N. P. Robins
Abstract:
We present a precision gravimeter based on coherent Bragg diffraction of freely falling cold atoms. Traditionally, atomic gravimeters have used stimulated Raman transitions to separate clouds in momentum space by driving transitions between two internal atomic states. Bragg interferometers utilize only a single internal state, and can therefore be less susceptible to environmental perturbations. H…
▽ More
We present a precision gravimeter based on coherent Bragg diffraction of freely falling cold atoms. Traditionally, atomic gravimeters have used stimulated Raman transitions to separate clouds in momentum space by driving transitions between two internal atomic states. Bragg interferometers utilize only a single internal state, and can therefore be less susceptible to environmental perturbations. Here we show that atoms extracted from a magneto-optical trap using an accelerating optical lattice are a suitable source for a Bragg atom interferometer, allowing efficient beamsplitting and subsequent separation of momentum states for detection. Despite the inherently multi-state nature of atom diffraction, we are able to build a Mach-Zehnder interferometer using Bragg scattering which achieves a sensitivity to the gravitational acceleration of $Δg/g = 2.7\times10^{-9}$ with an integration time of 1000s. The device can also be converted to a gravity gradiometer by a simple modification of the light pulse sequence.
△ Less
Submitted 6 July, 2012;
originally announced July 2012.
-
Relative intensity squeezing by four-wave mixing with loss: an analytic model and experimental diagnostic
Authors:
M. Jasperse,
L. D. Turner,
R. E. Scholten
Abstract:
Four-wave mixing near resonance in an atomic vapor can produce relative intensity squeezed light suitable for precision measurements beyond the shot-noise limit. We develop an analytic distributed gain/loss model to describe the competition of mixing and absorption through the non-linear medium. Using a novel matrix calculus, we present closed-form expressions for the degree of relative intensity…
▽ More
Four-wave mixing near resonance in an atomic vapor can produce relative intensity squeezed light suitable for precision measurements beyond the shot-noise limit. We develop an analytic distributed gain/loss model to describe the competition of mixing and absorption through the non-linear medium. Using a novel matrix calculus, we present closed-form expressions for the degree of relative intensity squeezing produced by this system. We use these theoretical results to analyze experimentally measured squeezing from a $^{85}$Rb vapor and demonstrate the analytic model's utility as an experimental diagnostic.
△ Less
Submitted 13 February, 2011; v1 submitted 15 December, 2010;
originally announced December 2010.