-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Approaching the motional ground state of a 10 kg object
Authors:
Chris Whittle,
Evan D. Hall,
Sheila Dwyer,
Nergis Mavalvala,
Vivishek Sudhir,
R. Abbott,
A. Ananyeva,
C. Austin,
L. Barsotti,
J. Betzwieser,
C. D. Blair,
A. F. Brooks,
D. D. Brown,
A. Buikema,
C. Cahillane,
J. C. Driggers,
A. Effler,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
T. Hardwick,
M. Kasprzack,
K. Kawabe,
N. Kijbunchoo,
J. S. Kissel
, et al. (175 additional authors not shown)
Abstract:
The motion of a mechanical object -- even a human-sized object -- should be governed by the rules of quantum mechanics. Coaxing them into a quantum state is, however, difficult: the thermal environment masks any quantum signature of the object's motion. Indeed, the thermal environment also masks effects of proposed modifications of quantum mechanics at large mass scales. We prepare the center-of-m…
▽ More
The motion of a mechanical object -- even a human-sized object -- should be governed by the rules of quantum mechanics. Coaxing them into a quantum state is, however, difficult: the thermal environment masks any quantum signature of the object's motion. Indeed, the thermal environment also masks effects of proposed modifications of quantum mechanics at large mass scales. We prepare the center-of-mass motion of a 10 kg mechanical oscillator in a state with an average phonon occupation of 10.8. The reduction in temperature, from room temperature to 77 nK, is commensurate with an 11 orders-of-magnitude suppression of quantum back-action by feedback -- and a 13 orders-of-magnitude increase in the mass of an object prepared close to its motional ground state. This begets the possibility of probing gravity on massive quantum systems.
△ Less
Submitted 9 July, 2021; v1 submitted 24 February, 2021;
originally announced February 2021.
-
Quantum correlations between the light and kilogram-mass mirrors of LIGO
Authors:
Haocun Yu,
L. McCuller,
M. Tse,
L. Barsotti,
N. Mavalvala,
J. Betzwieser,
C. D. Blair,
S. E. Dwyer,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
F. Matichard,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
C. Whittle,
A. Buikema,
Y. Chen,
T. R. Corbitt,
R. Schnabel
, et al. (174 additional authors not shown)
Abstract:
Measurement of minuscule forces and displacements with ever greater precision encounters a limit imposed by a pillar of quantum mechanics: the Heisenberg uncertainty principle. A limit to the precision with which the position of an object can be measured continuously is known as the standard quantum limit (SQL). When light is used as the probe, the SQL arises from the balance between the uncertain…
▽ More
Measurement of minuscule forces and displacements with ever greater precision encounters a limit imposed by a pillar of quantum mechanics: the Heisenberg uncertainty principle. A limit to the precision with which the position of an object can be measured continuously is known as the standard quantum limit (SQL). When light is used as the probe, the SQL arises from the balance between the uncertainties of photon radiation pressure imposed on the object and of the photon number in the photoelectric detection. The only possibility surpassing the SQL is via correlations within the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light it reflects. Here, we experimentally prove the theoretical prediction that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). Our measurements show that the quantum mechanical uncertainties in the phases of the 200 kW laser beams and in the positions of the 40 kg mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty a factor of 1.4 (3dB) below the SQL. We anticipate that quantum correlations will not only improve gravitational wave (GW) observatories but all types of measurements in future.
△ Less
Submitted 4 February, 2020;
originally announced February 2020.
-
Quantum noise cancellation in asymmetric speed meters with balanced homodyne readout
Authors:
T Zhang,
E Knyazev,
S Steinlechner,
F Ya Khalili,
B W Barr,
A S Bell,
P Dupej,
C Gräf,
J Callaghan,
J S Hennig,
E A Houston,
S H Huttner,
S S Leavey,
D Pascucci,
B Sorazu,
A Spencer,
J Wright,
K A Strain,
S L Danilishin,
S Hild
Abstract:
Sagnac speed meter (SSM) topology is known as an alternative technique to reduce quantum back-action in gravitational-wave interferometers. However, any potential imbalance of the main beamsplitter was shown to reduce the quantum noise superiority of speed meter at low frequencies, caused due to increased laser noise coupling to the detection port. In this paper, we show that implementing balanced…
▽ More
Sagnac speed meter (SSM) topology is known as an alternative technique to reduce quantum back-action in gravitational-wave interferometers. However, any potential imbalance of the main beamsplitter was shown to reduce the quantum noise superiority of speed meter at low frequencies, caused due to increased laser noise coupling to the detection port. In this paper, we show that implementing balanced homodyne readout scheme and for a particular choice of the local oscillator (LO) delivery port, the excess laser noise contribution to quantum noise limited sensitivity (QNLS) is partly compensated and the speed meter sensitivity can outperform state-of-the-art position meters. This can be achieved by picking the local oscillator from interferometer reflection (\textit{co-moving} LO) or the main beamsplitter anti-reflective coating surface (BSAR LO). We also show that this relaxes the relative intensity noise (RIN) requirement of the input laser. For example, for a beam splitter imbalance of $0.1 \%$ in Glasgow speed meter proof of concept experiment, the RIN requirement at frequency of 100Hz decreases from $4\times 10^{-10}/\sqrt{\rm Hz}$ to $4\times 10^{-7}/\sqrt{\rm Hz}$, moving the RIN requirement from a not practical achievable value to one which is routinely achieved with moderate effort.
△ Less
Submitted 14 June, 2018;
originally announced June 2018.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors
Authors:
Teng Zhang,
Stefan L Danilishin,
Sebastian Steinlechner,
Bryan W Barr,
Angus S Bell,
Peter Dupej,
Christian Gräf,
Jan-Simon Hennig,
E Alasdair Houston,
Sabina H Huttner,
Sean S Leavey,
Daniela Pascucci,
Borja Sorazu,
Andrew Spencer,
Jennifer Wright,
Kenneth A Strain,
Stefan Hild
Abstract:
With the recent discovery of Gravitational waves, marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for u…
▽ More
With the recent discovery of Gravitational waves, marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum noise limited sensitivity is independent of the actual interferometer configuration, e.g. Michelson and Sagnac interferometers are effected in the same way. We show that output misalignment only effects the high frequency part of the quantum noise limited sensitivity. However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise by the same amount and hence the quantum noise limited sensitivity is not negatively effected. We show that the input misalignment to the interferometer produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof of concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment.
△ Less
Submitted 2 February, 2017; v1 submitted 2 December, 2016;
originally announced December 2016.
-
Control of a velocity-sensitive audio-band quantum non-demolition interferometer
Authors:
S. S. Leavey,
S. L. Danilishin,
A. Gläfke,
B. W. Barr,
A. S. Bell,
C. Gräf,
J. -S. Hennig,
E. A. Houston,
S. H. Huttner,
H. Lück,
D. Pascucci,
K. Somiya,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
J. Wright,
T. Zhang,
S. Hild
Abstract:
The Sagnac speed meter interferometer topology can potentially provide enhanced sensitivity to gravitational waves in the audio-band compared to equivalent Michelson interferometers. A challenge with the Sagnac speed meter interferometer arises from the intrinsic lack of sensitivity at low frequencies where the velocity-proportional signal is smaller than the noise associated with the sensing of t…
▽ More
The Sagnac speed meter interferometer topology can potentially provide enhanced sensitivity to gravitational waves in the audio-band compared to equivalent Michelson interferometers. A challenge with the Sagnac speed meter interferometer arises from the intrinsic lack of sensitivity at low frequencies where the velocity-proportional signal is smaller than the noise associated with the sensing of the signal. Using as an example the on-going proof-of-concept Sagnac speed meter experiment in Glasgow, we quantify the problem and present a solution involving the extraction of a small displacement-proportional signal. This displacement signal can be combined with the existing velocity signal to enhance low frequency sensitivity, and we derive optimal filters to accomplish this for different signal strengths. We show that the extraction of the displacement signal for low frequency control purposes can be performed without reducing significantly the quantum non-demolition character of this type of interferometer.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
Design of a speed meter interferometer proof-of-principle experiment
Authors:
C. Gräf,
B. W. Barr,
A. S. Bell,
F. Campbell,
A. V. Cumming,
S. L. Danilishin,
N. A. Gordon,
G. D. Hammond,
J. Hennig,
E. A. Houston,
S. H. Huttner,
R. A. Jones,
S. S. Leavey,
H. Lück,
J. Macarthur,
M. Marwick,
S. Rigby,
R. Schilling,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
S. Hild
Abstract:
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo…
▽ More
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.
△ Less
Submitted 11 September, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Optical layout for a 10m Fabry-Pérot Michelson interferometer with tunable stability
Authors:
Christian Gräf,
Stefan Hild,
Harald Lück,
Benno Willke,
Kenneth A. Strain,
Stefan Goßler,
Karsten Danzmann
Abstract:
The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible bea…
▽ More
The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible beam size. In this article we describe the optical design of a 10\,m Fabry-Pérot Michelson interferometer with tunable stability. Our design will allow us to carry out initial commissioning with arm cavities of high stability, while afterwards the arm cavity length can be increased stepwise towards the final, marginally stable configuration. Requiring only minimal hardware changes, with respect to a comparable "static" layout, the proposed technique will not only enable us to explore the stability limits of an optical resonator with realistic mirrors exhibiting inevitable surface imperfections, but also the opportunity to measure coating Brownian noise at frequencies as low as a few hundred Hertz. A detailed optical design of the tunable interferometer is presented and requirements for the optical elements are derived from robustness evaluations.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
The 10m AEI prototype facility A brief overview
Authors:
Tobias Westphal,
Gerald Bergmann,
Alessandro Bertolini,
Michael Born,
Yanbei Chen,
Alan V Cumming,
Liam Cunningham,
Katrin Dahl,
Christian Graef,
Giles Hammond,
Gerhard Heinzel,
Stefan Hild,
Sabina Huttner,
Russel Jones,
Fumiko Kawazoe,
Sina Koehlenbeck,
Gerrit Kuehn,
Harald Lueck,
Kasem Mossavi,
Jan H Poeld,
Kentaro Somiya,
Marielle van Veggel,
Alexander Wanner,
Benno Willke,
Ken A Strain
, et al. (2 additional authors not shown)
Abstract:
The AEI 10 m prototype interferometer facility is currently being constructed at the Albert Einstein Institute in Hannover, Germany. It aims to perform experiments for future gravitational wave detectors using advanced techniques. Seismically isolated benches are planned to be interferometrically interconnected and stabilized, forming a low-noise testbed inside a 100 m^3 ultra-high vacuum system.…
▽ More
The AEI 10 m prototype interferometer facility is currently being constructed at the Albert Einstein Institute in Hannover, Germany. It aims to perform experiments for future gravitational wave detectors using advanced techniques. Seismically isolated benches are planned to be interferometrically interconnected and stabilized, forming a low-noise testbed inside a 100 m^3 ultra-high vacuum system. A well-stabilized high power laser will perform differential position readout of 100 g test masses in a 10 m suspended arm-cavity enhanced Michelson interferometer at the crossover of measurement (shot) noise and backaction (quantum radiation pressure) noise, the so-called Standard Quantum Limit (SQL). Such a sensitivity enables experiments in the highly topical field of macroscopic quantum mechanics. In this article we introduce the experimental facility and describe the methods employed, technical details of subsystems will be covered in future papers.
△ Less
Submitted 28 December, 2011; v1 submitted 30 November, 2011;
originally announced November 2011.