Enhancement of Sensitivity-Bandwidth Product of Interferometric GW Detectors using White Light Cavities
Authors:
M. Salit,
M. S. Shahriar
Abstract:
The effect of gravitational waves (GWs) has been observed indirectly, by monitoring the change in the orbital frequency of neutron stars in a binary system as they lose energy via gravitational radiation. However, GWs have not yet been observed directly. The initial LIGO apparatus has not yet observed GWs. The Advanced LIGO (AdLIGO) will use a combination of improved techniques in order to incre…
▽ More
The effect of gravitational waves (GWs) has been observed indirectly, by monitoring the change in the orbital frequency of neutron stars in a binary system as they lose energy via gravitational radiation. However, GWs have not yet been observed directly. The initial LIGO apparatus has not yet observed GWs. The Advanced LIGO (AdLIGO) will use a combination of improved techniques in order to increase the sensitivity. Along with power recycling and a higher power laser source, the AdLIGO will employ signal recycling (SR). While SR would increase sensitivity, it would also reduce the bandwidth significantly. Previously, we and others have investigated, theoretically and experimentally, the feasibility of using a White Light Cavity (WLC) to circumvent this constraint. However, in the previous work, it was not clear how one would incorporate the white light cavity effect. Here, we first develop a general model for Michelson-Interferometer based GW detectors that can be easily adapted to include the effects of incorporating a WLC into the design. We then describe a concrete design of a WLC constructed as a compound mirror, to replace the signal recycling mirror. This design is simple, robust, completely non-invasive, and can be added to the AdLIGO system without changing any other optical elements. We show a choice of parameters for which the signal sensitivity as well as the bandwidth are enhanced significantly over what is planned for the AdLIGO, covering the entire spectrum of interest for gravitational waves.
△ Less
Submitted 11 June, 2009; v1 submitted 24 September, 2008;
originally announced September 2008.
-
Fast-Light in a Photorefractive Crystal for Gravitational Wave Detection
Authors:
H. N. Yum,
M. Salit,
G. S. Pati,
S. Tseng,
P. R. Hemmer,
M. S. Shahriar
Abstract:
We demonstrate superluminal light propagation using two frequency multiplexed pump beams to produce a gain doublet in a photorefractive crystal of Ce:BaTiO3. The two gain lines are obtained by two-wave mixing between a probe field and two individual pump fields. The angular frequencies of the pumps are symmetrically tuned from the frequency of the probe. The frequency difference between the pump…
▽ More
We demonstrate superluminal light propagation using two frequency multiplexed pump beams to produce a gain doublet in a photorefractive crystal of Ce:BaTiO3. The two gain lines are obtained by two-wave mixing between a probe field and two individual pump fields. The angular frequencies of the pumps are symmetrically tuned from the frequency of the probe. The frequency difference between the pumps corresponds to the separation of the two gain lines; as it increases, the crystal gradually converts from normal dispersion without detuning to an anomalously dispersive medium. The time advance is measured as 0.28 sec for a pulse propagating through a medium with a 2Hz gain separation, compared to the same pulse propagating through empty space. We also demonstrate directly anomalous dispersion profile using a modfied experimental configuration. Finally, we discuss how anomalous dispersion produced this way in a faster photorefractive crystal (such as SPS: Sn2P2S6) could be employed to enhance the sensitivity-bandwidth product of a LIGO type gravitational wave detector augmented by a White Light Cavity.
△ Less
Submitted 23 September, 2008;
originally announced September 2008.
-
Demonstration of Tunable Displacement-Measurement-Sensitivity using Variable Group Index in a Ring Resonator
Authors:
G. S. Pati,
M. Salit,
K. Salit,
M. S. Shahriar
Abstract:
We show that an intra-cavity medium with normal dispersion reduces the sensitivity of the cavity resonance frequency to a change in its length by a factor inversely proportional to the group index. Since the group index in an atomic medium can be very large, this effect can help in constructing highly frequency-stable cavities for various potential applications without taking additional measures…
▽ More
We show that an intra-cavity medium with normal dispersion reduces the sensitivity of the cavity resonance frequency to a change in its length by a factor inversely proportional to the group index. Since the group index in an atomic medium can be very large, this effect can help in constructing highly frequency-stable cavities for various potential applications without taking additional measures for mechanical stability. The results also establish indirectly the opposite effect of enhanced sensitivity that can be realized for a negative dispersion corresponding to a group index close to a null value. This enhancement in turn can be employed to increase significantly the sensitivity of a ring laser gyroscope.
△ Less
Submitted 21 February, 2007; v1 submitted 4 October, 2006;
originally announced October 2006.
-
Demonstration of a Tunable-Bandwidth White Light Interferometer using Anomalous Dispersion in Atomic Vapor
Authors:
G. S. Pati,
M. Salit,
K. Salit,
M. S. Shahriar
Abstract:
Recently, the design of a white-light-cavity has been proposed using negative dispersion in an intra-cavity medium to make the cavity resonate over a large range of frequencies and still maintain a high cavity build-up. This paper presents the demonstration of this effect in a free-space cavity. The negative dispersion of the intra-cavity medium is caused by bi-frequency Raman gain in an atomic…
▽ More
Recently, the design of a white-light-cavity has been proposed using negative dispersion in an intra-cavity medium to make the cavity resonate over a large range of frequencies and still maintain a high cavity build-up. This paper presents the demonstration of this effect in a free-space cavity. The negative dispersion of the intra-cavity medium is caused by bi-frequency Raman gain in an atomic vapor cell. A significantly broad cavity response over a bandwidth greater than 20 MHz has been observed. The experimental results agree well with the theoretical model, taking into account effects of residual absorption. A key application of this device would be in enhancing the sensitivity-bandwidth product of the next generation gravitational wave detectors that make use of the so-called signal-recycling mirror.
△ Less
Submitted 11 June, 2007; v1 submitted 4 October, 2006;
originally announced October 2006.