-
Performance Stabilization of High-Coherence Superconducting Qubits
Authors:
Andrew Dane,
Karthik Balakrishnan,
Brent Wacaser,
Li-Wen Hung,
H. J. Mamin,
Daniel Rugar,
Robert M. Shelby,
Conal Murray,
Kenneth Rodbell,
Jeffrey Sleight
Abstract:
Superconducting qubits have been used in the most advanced demonstrations of quantum information processing, and they can be manufactured at-scale using proven semiconductor techniques. This makes them one of the leading technologies in the race to demonstrate useful quantum computers. Since their initial demonstration, advances in design, fabrication, and materials have extended the timescales ov…
▽ More
Superconducting qubits have been used in the most advanced demonstrations of quantum information processing, and they can be manufactured at-scale using proven semiconductor techniques. This makes them one of the leading technologies in the race to demonstrate useful quantum computers. Since their initial demonstration, advances in design, fabrication, and materials have extended the timescales over which fragile quantum information can be stored and manipulated on superconducting qubits. Ubiquitous atomic-scale material defects have been identified as a primary cause of qubit energy-loss and decoherence. Here we study transmon qubits that exhibit energy relaxation times exceeding 2.5 ms. Even at these long timescales, our qubit energy loss is dominated by two level systems (TLS). We observe large variations in these energy-loss times that would make it extremely difficult to accurately evaluate and compare qubit fabrication processes and to perform studies that require precise measurements of energy loss. To address this issue, we present a technique for characterizing qubit quality factor. In this method, we apply a slowly varying electric field to TLS near the qubit to stabilize the measured energy relaxation time, enabling us to replace hundreds of hours of measurements with ones that span several minutes.
△ Less
Submitted 16 March, 2025;
originally announced March 2025.
-
Merged-Element Transmons: Design and Qubit Performance
Authors:
H. J. Mamin,
E. Huang,
S. Carnevale,
C. T. Rettner,
N. Arellano,
M. H. Sherwood,
C. Kurter,
B. Trimm,
M. Sandberg,
R. M. Shelby,
M. A. Mueed,
B. A. Madon,
A. Pushp,
M. Steffen,
D. Rugar
Abstract:
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field part…
▽ More
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field participation from other interfaces. By combining micrometer-scale Al/AlOx/Al junctions with long oxidations and novel processing, we have produced functional devices with $E_{J}$/$E_{C}$ in the low transmon regime ($E_{J}$/$E_{C}$ $\lesssim$30). Cryogenic I-V measurements show sharp dI/dV structure with low sub-gap conduction. Qubit spectroscopy of tunable versions show a small number of avoided level crossings, suggesting the presence of two-level systems (TLS). We have observed mean T1 times typically in the range of 10-90 microseconds, with some annealed devices exhibiting T1 > 100 microseconds over several hours. The results suggest that energy relaxation in conventional, small-junction transmons is not limited by junction loss.
△ Less
Submitted 13 August, 2021; v1 submitted 16 March, 2021;
originally announced March 2021.
-
Spurious harmonic response of multipulse quantum sensing sequences
Authors:
M. Loretz,
J. M. Boss,
T. Rosskopf,
H. J. Mamin,
D. Rugar,
C. L. Degen
Abstract:
Multipulse sequences based on Carr-Purcell decoupling are frequently used for narrow-band signal detection in single spin magnetometry. We have analyzed the behavior of multipulse sensing sequences under real-world conditions, including finite pulse durations and the presence of detunings. We find that these non-idealities introduce harmonics to the filter function, allowing additional frequencies…
▽ More
Multipulse sequences based on Carr-Purcell decoupling are frequently used for narrow-band signal detection in single spin magnetometry. We have analyzed the behavior of multipulse sensing sequences under real-world conditions, including finite pulse durations and the presence of detunings. We find that these non-idealities introduce harmonics to the filter function, allowing additional frequencies to pass the filter. In particular, we find that the XY family of sequences can generate signals at the 2fac, 4fac and 8fac harmonics and their odd subharmonics, where fac is the ac signal frequency. Consideration of the harmonic response is especially important for diamond-based nuclear spin sensing where the NMR frequency is used to identify the nuclear spin species, as it leads to ambiguities when several isotopes are present.
△ Less
Submitted 6 May, 2015; v1 submitted 18 December, 2014;
originally announced December 2014.
-
Multipulse Double-Quantum Magnetometry With Near-Surface Nitrogen Vacancy Centers
Authors:
H. J. Mamin,
M. H. Sherwood,
M. Kim,
C. T. Rettner,
K. Ohno,
D. D. Awschalom,
D. Rugar
Abstract:
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual…
▽ More
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a 4 times enhancement theoretically possible.
△ Less
Submitted 15 July, 2015; v1 submitted 29 April, 2014;
originally announced April 2014.
-
Electron spin detection in the frequency domain under the interrupted Oscillating Cantilever-driven Adiabatic Reversal (iOSCAR) Protocol
Authors:
M. Ting,
A. O. Hero,
D. Rugar,
C. Y. Yip,
J. A. Fessler
Abstract:
Magnetic Resonance Force Microscopy (MRFM) is an emergent technology for measuring spin-induced attonewton forces using a micromachined cantilever. In the interrupted Oscillating Cantilever-driven Adiabatic Reversal (iOSCAR) method, small ensembles of electron spins are manipulated by an external radio frequency (RF) magnetic field to produce small periodic deviations in the resonant frequency o…
▽ More
Magnetic Resonance Force Microscopy (MRFM) is an emergent technology for measuring spin-induced attonewton forces using a micromachined cantilever. In the interrupted Oscillating Cantilever-driven Adiabatic Reversal (iOSCAR) method, small ensembles of electron spins are manipulated by an external radio frequency (RF) magnetic field to produce small periodic deviations in the resonant frequency of the cantilever. These deviations can be detected by frequency demodulation, followed by conventional amplitude or energy detection. In this paper, we develop optimal detectors for several signal models that have been hypothesized for measurements induced by iOSCAR spin manipulation. We show that two simple variants of the energy detector--the filtered energy detector and a hybrid filtered energy/amplitude/energy detector--are approximately asymptotically optimal for the Discrete-Time (D-T) random telegraph signal model assuming White Gaussian Noise (WGN). For the D-T random walk signal model, the filtered energy detector performs close to the optimal Likelihood Ratio Test (LRT) when the transition probabilities are symmetric.
△ Less
Submitted 14 January, 2004; v1 submitted 15 December, 2003;
originally announced December 2003.
-
Baseband Detection of Bistatic Electron Spin Signals in Magnetic Resonance Force Microscopy (MRFM)
Authors:
Chun-yu Yip,
Alfred O. Hero,
Daniel Rugar,
Jeffrey A. Fessler
Abstract:
In single spin Magnetic Resonance Force Microscopy (MRFM), the objective is to detect the presence of an electron (or nuclear) spin in a sample volume by measuring spin-induced attonewton forces using a micromachined cantilever. In the OSCAR method of single spin MRFM, the spins are manipulated by an external rf field to produce small periodic deviations in the resonant frequency of the cantilev…
▽ More
In single spin Magnetic Resonance Force Microscopy (MRFM), the objective is to detect the presence of an electron (or nuclear) spin in a sample volume by measuring spin-induced attonewton forces using a micromachined cantilever. In the OSCAR method of single spin MRFM, the spins are manipulated by an external rf field to produce small periodic deviations in the resonant frequency of the cantilever. These deviations can be detected by frequency demodulation followed by conventional amplitude or energy detection. In this paper, we present an alternative to these detection methods, based on optimal detection theory and Gibbs sampling. On the basis of simulations, we show that our detector outperforms the conventional amplitude and energy detectors for realistic MRFM operating conditions. For example, to achieve a 10% false alarm rate and an 80% correct detection rate our detector has an 8 dB SNR advantage as compared with the conventional amplitude or energy detectors. Furthermore, at these detection rates it comes within 4 dB of the omniscient matched-filter lower bound.
△ Less
Submitted 20 August, 2003; v1 submitted 7 July, 2003;
originally announced July 2003.
-
Spin Relaxation Caused by Thermal Excitations of High Frequency Modes of Cantilever Vibrations
Authors:
G. P. Berman,
V. N. Gorshkov,
D. Rugar,
V. I. Tsifrinovich
Abstract:
We consider the process of spin relaxation in the oscillating cantilever-driven adiabatic reversals technique in magnetic resonance force microscopy. We simulated the spin relaxation caused by thermal excitations of the high frequency cantilever modes in the region of the Rabi frequency of the spin sub-system. The minimum relaxation time obtained in our simulations is greater but of the same ord…
▽ More
We consider the process of spin relaxation in the oscillating cantilever-driven adiabatic reversals technique in magnetic resonance force microscopy. We simulated the spin relaxation caused by thermal excitations of the high frequency cantilever modes in the region of the Rabi frequency of the spin sub-system. The minimum relaxation time obtained in our simulations is greater but of the same order of magnitude as one measured in recent experiments. We demonstrated that using a cantilever with nonuniform cross-sectional area may significantly increase spin relaxation time.
△ Less
Submitted 28 March, 2003;
originally announced March 2003.