High accuracy, high dynamic range optomechanical accelerometry enabled by dual comb spectroscopy
Authors:
D. A. Long,
J. R. Stroud,
B. J. Reschovsky,
Y. Bao,
F. Zhou,
S. M. Bresler,
T. W. LeBrun,
D. F. Plusquellic,
J. J. Gorman
Abstract:
Cavity optomechanical sensors can offer exceptional sensitivity; however, interrogating the cavity motion with high accuracy and dynamic range has proven to be challenging. Here we employ a dual optical frequency comb spectrometer to readout a microfabricated cavity optomechanical accelerometer, allowing for rapid simultaneous measurements of the cavity's displacement, finesse, and coupling at acc…
▽ More
Cavity optomechanical sensors can offer exceptional sensitivity; however, interrogating the cavity motion with high accuracy and dynamic range has proven to be challenging. Here we employ a dual optical frequency comb spectrometer to readout a microfabricated cavity optomechanical accelerometer, allowing for rapid simultaneous measurements of the cavity's displacement, finesse, and coupling at accelerations up to 24 g (236 m/s$^2$). With this approach, we have achieved a displacement sensitivity of 3 fm/Hz$^{1/2}$, a measurement rate of 100 kHz, and a dynamic range of 3.9 $\times$ 10$^5$ which is the highest we are aware of for a microfabricated cavity optomechanical sensor. In addition, comparisons of our optomechanical sensor coupled directly to a commercial reference accelerometer show agreement at the 0.5% level, a value which is limited by the reference's reported uncertainty. Further, the methods described herein are not limited to accelerometry but rather can be readily applied to nearly any optomechanical sensor where the combination of high speed, dynamic range, and sensitivity is expected to be enabling.
△ Less
Submitted 10 October, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
Narrow-line photoassociation spectroscopy and mass-scaling of bosonic strontium
Authors:
B. J. Reschovsky,
B. P. Ruzic,
H. Miyake,
N. C. Pisenti,
P. S. Julienne,
G. K. Campbell
Abstract:
Using new experimental measurements of photoassociation resonances near the $^1\mathrm{S}_0 \rightarrow \phantom{ }^3\mathrm{P}_1$ intercombination transition in $^{84}$Sr and $^{86}$Sr, we present an updated study into the mass-scaling behavior of bosonic strontium dimers. A previous mass-scaling model [Borkowski et al., Phys. Rev. A 90, 032713 (2014)] was able to incorporate a large number of ph…
▽ More
Using new experimental measurements of photoassociation resonances near the $^1\mathrm{S}_0 \rightarrow \phantom{ }^3\mathrm{P}_1$ intercombination transition in $^{84}$Sr and $^{86}$Sr, we present an updated study into the mass-scaling behavior of bosonic strontium dimers. A previous mass-scaling model [Borkowski et al., Phys. Rev. A 90, 032713 (2014)] was able to incorporate a large number of photoassociation resonances for $^{88}$Sr, but at the time only a handful of resonances close to the dissociation limit were known for $^{84}$Sr and $^{86}$Sr. In this work, we perform a more thorough measurement of $^{84}$Sr and $^{86}$Sr bound states, identifying multiple new resonances at deeper binding energies out to $E/h=-5$ GHz. We also identify several previously measured resonances that cannot be experimentally reproduced and provide alternative binding energies instead. With this improved spectrum, we develop a mass-scaled model that reproduces the observed binding energies of $^{86}$Sr and $^{88}$Sr to within 1 MHz. In order to accurately reproduce the deeper bound states, our model includes a second $1_u$ channel and more faithfully reproduces the depth of the potential. As determined by the previous mass-scaling study, $^{84}$Sr $0_u^+$ levels are strongly perturbed by the avoided crossing between the $^1\mathrm{S}_0 + \phantom{ }^3\mathrm{P}_1$ $0_u^+$ $(^3Π_u)$ and $^1\mathrm{S}_0 + \phantom{ }^1\mathrm{D}_2$ $0_u^+$ $(^1Σ_u^+)$ potential curves and therefore are not included in this mass-scaled model, but are accurately reproduced using an isotope-specific model with slightly different quantum defect parameters. In addition, the optical lengths of the $^{84}$Sr $0_u^+,\ ν=-2$ to $ν=-5$ states are measured and compared to numerical estimates to characterize their use as optical Feshbach resonances.
△ Less
Submitted 23 October, 2018; v1 submitted 20 August, 2018;
originally announced August 2018.