Polarimetry for measuring the vacuum magnetic birefringence with quasi-static fields: a systematics study for the VMB@CERN experiment
Authors:
G. Zavattini,
F. Della Valle,
A. M Soflau,
L. Formaggio,
G. Crapulli,
G. Messineo,
E. Mariotti,
S. Kunc,
A. Ejlli,
G. Ruoso,
C. Marinelli,
M. Andreotti
Abstract:
We present an experimental systematics study of the polarimetric method for measuring the vacuum magnetic birefringence based on a pair of rotating half-wave plates. The presence of a systematic effect at the same frequency as the sought for magneto-optical effect inhibits the use of strictly constant magnetic fields. We characterise this systematic, discuss its origin and propose a viable workaro…
▽ More
We present an experimental systematics study of the polarimetric method for measuring the vacuum magnetic birefringence based on a pair of rotating half-wave plates. The presence of a systematic effect at the same frequency as the sought for magneto-optical effect inhibits the use of strictly constant magnetic fields. We characterise this systematic, discuss its origin and propose a viable workaround.
△ Less
Submitted 13 January, 2022; v1 submitted 8 October, 2021;
originally announced October 2021.
-
The PVLAS experiment: measuring vacuum magnetic birefringence and dichroism with a birefringent Fabry-Perot cavity
Authors:
F. Della Valle,
E. Milotti,
A. Ejlli,
U. Gastaldi,
G. Messineo,
G. Zavattini,
R. Pengo,
G. Ruoso
Abstract:
Vacuum magnetic birefringence was predicted long time ago and is still lacking a direct experimental confirmation. Several experimental efforts are striving to reach this goal, and the sequence of results promises a success in the next few years. This measurement generally is accompanied by the search for hypothetical light particles that couple to two photons. The PVLAS experiment employs a sensi…
▽ More
Vacuum magnetic birefringence was predicted long time ago and is still lacking a direct experimental confirmation. Several experimental efforts are striving to reach this goal, and the sequence of results promises a success in the next few years. This measurement generally is accompanied by the search for hypothetical light particles that couple to two photons. The PVLAS experiment employs a sensitive polarimeter based on a high finesse Fabry-Perot cavity. In this paper we report on the latest experimental results of this experiment. The data are analysed taking into account the intrinsic birefringence of the dielectric mirrors of the cavity. Besides the limit on the vacuum magnetic birefringence, the measurements also allow the model-independent exclusion of new regions in the parameter space of axion-like and milli-charged particles. In particular, these last limits hold also for all types of neutrinos, resulting in a laboratory limit on their charge.
△ Less
Submitted 27 October, 2015;
originally announced October 2015.
-
First results from the new PVLAS apparatus: a new limit on vacuum magnetic birefringence
Authors:
F. Della Valle,
E. Milotti,
A. Ejlli,
G. Messineo,
L. Piemontese,
G. Zavattini,
U. Gastaldi,
R. Pengo,
G. Ruoso
Abstract:
Several groups are carrying out experiments to observe and measure vacuum magnetic birefringence, predicted by Quantum Electrodynamics (QED). We have started running the new PVLAS apparatus installed in Ferrara, Italy, and have measured a noise floor value for the unitary field magnetic birefringence of vacuum $Δn_u^{\rm (vac)}= (4\pm 20) \times 10^{-23}$ T$^{-2}$ (the error represents a 1$σ$ devi…
▽ More
Several groups are carrying out experiments to observe and measure vacuum magnetic birefringence, predicted by Quantum Electrodynamics (QED). We have started running the new PVLAS apparatus installed in Ferrara, Italy, and have measured a noise floor value for the unitary field magnetic birefringence of vacuum $Δn_u^{\rm (vac)}= (4\pm 20) \times 10^{-23}$ T$^{-2}$ (the error represents a 1$σ$ deviation). This measurement is compatible with zero and hence represents a new limit on vacuum magnetic birefringence deriving from non linear electrodynamics. This result reduces to a factor 50 the gap to be overcome to measure for the first time the value of $Δn_u^{\rm (vac,QED)}$ predicted by QED: $Δn_u^{\rm (vac,QED)}= 4\times 10^{-24}$ ~T$^{-2}$. These birefringence measurements also yield improved model-independent bounds on the coupling constant of axion-like particles to two photons, for masses greater than 1 meV, along with a factor two improvement of the fractional charge limit on millicharged particles (fermions and scalars), including neutrinos.
△ Less
Submitted 15 September, 2014; v1 submitted 25 June, 2014;
originally announced June 2014.
-
Measurements of vacuum magnetic birefringence using permanent dipole magnets: the PVLAS experiment
Authors:
F. Della Valle,
U. Gastaldi,
G. Messineo,
E. Milotti,
R. Pengo,
L. Piemontese,
G. Ruoso,
G. Zavattini
Abstract:
The PVLAS collaboration is presently assembling a new apparatus (at the INFN section of Ferrara, Italy) to detect vacuum magnetic birefringence (VMB). VMB is related to the structure of the QED vacuum and is predicted by the Euler-Heisenberg-Weisskopf effective Lagrangian. It can be detected by measuring the ellipticity acquired by a linearly polarised light beam propagating through a strong magne…
▽ More
The PVLAS collaboration is presently assembling a new apparatus (at the INFN section of Ferrara, Italy) to detect vacuum magnetic birefringence (VMB). VMB is related to the structure of the QED vacuum and is predicted by the Euler-Heisenberg-Weisskopf effective Lagrangian. It can be detected by measuring the ellipticity acquired by a linearly polarised light beam propagating through a strong magnetic field. Using the very same optical technique it is also possible to search for hypothetical low-mass particles interacting with two photons, such as axion-like (ALP) or millicharged particles (MCP). Here we report results of a scaled-down test setup and describe the new PVLAS apparatus. This latter one is in construction and is based on a high-sensitivity ellipsometer with a high-finesse Fabry-Perot cavity ($>4\times 10^5$) and two 0.8 m long 2.5 T rotating permanent dipole magnets. Measurements with the test setup have improved by a factor 2 the previous upper bound on the parameter $A_e$, which determines the strength of the nonlinear terms in the QED Lagrangian: $A_e^{\rm (PVLAS)} < 3.3 \times 10^{-21}$ T$^{-2}$ 95% c.l. Furthermore, new laboratory limits have been put on the inverse coupling constant of ALPs to two photons and confirmation of previous limits on the fractional charge of millicharged particles is given.
△ Less
Submitted 21 January, 2013;
originally announced January 2013.
-
An experimental apparatus for measuring the Casimir effect at large distances
Authors:
P Antonini,
G Bimonte,
G Bressi,
G Carugno,
G Galeazzi,
G Messineo,
G Ruoso
Abstract:
An experimental set-up for the measurement of the Casimir effect at separations larger than a few microns is presented. The apparatus is based on a mechanical resonator and uses a homodyne detection technique to sense the Casimir force in the plane-parallel configuration. First measurements in the 3-10 micrometer range show an unexpected large force probably due to patch effects.
An experimental set-up for the measurement of the Casimir effect at separations larger than a few microns is presented. The apparatus is based on a mechanical resonator and uses a homodyne detection technique to sense the Casimir force in the plane-parallel configuration. First measurements in the 3-10 micrometer range show an unexpected large force probably due to patch effects.
△ Less
Submitted 30 December, 2008;
originally announced December 2008.