-
Accurate measurement of the Sagnac effect for matter waves
Authors:
Romain Gautier,
Mohamed Guessoum,
Leonid A. Sidorenkov,
Quentin Bouton,
Arnaud Landragin,
Remi Geiger
Abstract:
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers.The fundamental importance of the Sagnac effec…
▽ More
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers.The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge.Here we report the accurate test of the Sagnac effect for matter waves, by using a Cesium-atom interferometer featuring a geometrical area of 11 cm$^2$ and two sensitive axes of measurements. We measure the phase shift induced by the Earth's rotation and find agreement with the theoretical prediction at an accuracy level of 25 ppm. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.
△ Less
Submitted 14 June, 2022;
originally announced June 2022.
-
Testing the Universality of Free Fall using correlated $^{39}$K -- $^{87}$Rb interferometers
Authors:
Brynle Barrett,
Gabriel Condon,
Laure Chichet,
Laura Antoni-Micollier,
Romain Arguel,
Martin Rabault,
Celia Pelluet,
Vincent Jarlaud,
Arnaud Landragin,
Philippe Bouyer,
Baptiste Battelier
Abstract:
We demonstrate how simultaneously-operated $^{39}$K -- $^{87}$Rb interferometers exhibiting a high level of correlation can be used to make competitive tests of the university of free fall. This work provides an overview of our experimental apparatus and data analysis procedure, including a detailed study of systematic effects. With a total interrogation time of $2T = 40$ ms in a compact apparatus…
▽ More
We demonstrate how simultaneously-operated $^{39}$K -- $^{87}$Rb interferometers exhibiting a high level of correlation can be used to make competitive tests of the university of free fall. This work provides an overview of our experimental apparatus and data analysis procedure, including a detailed study of systematic effects. With a total interrogation time of $2T = 40$ ms in a compact apparatus, we reach a statistical uncertainty on the measurement of the Eötvös parameter of $7.8 \times 10^{-8}$ after $2.4 \times 10^4$ s of integration. The main limitations to our measurement arise from a combination of wavefront aberrations, the quadratic Zeeman effect in $^{39}$K, parasitic interferometers in $^{87}$Rb, and the velocity sensitivity of our detection system. These systematic errors limit the accuracy of our measurement to $η= 0.9(1.6) \times 10^{-6}$. We discuss prospects for improvements using ultracold atoms at extended interrogation times.
△ Less
Submitted 25 October, 2021;
originally announced October 2021.
-
Tailoring multi-loop atom interferometers with adjustable momentum transfer
Authors:
L. A. Sidorenkov,
R. Gautier,
M. Altorio,
R. Geiger,
A. Landragin
Abstract:
Multi-loop matter-wave interferometers are essential in quantum sensing to measure the derivatives of physical quantities in time or space. Because multi-loop interferometers require multiple reflections, imperfections of the matter-wave mirrors create spurious paths that scramble the signal of interest. Here we demonstrate a method of adjustable momentum transfer that prevents the recombination o…
▽ More
Multi-loop matter-wave interferometers are essential in quantum sensing to measure the derivatives of physical quantities in time or space. Because multi-loop interferometers require multiple reflections, imperfections of the matter-wave mirrors create spurious paths that scramble the signal of interest. Here we demonstrate a method of adjustable momentum transfer that prevents the recombination of the spurious paths in a double-loop atom interferometer aimed at measuring rotation rates. We experimentally study the recombination condition of the spurious matter waves, which is quantitatively supported by a model accounting for the coherence properties of the atomic source. We finally demonstrate the effectiveness of the method in building a cold-atom gyroscope with a single-shot acceleration sensitivity suppressed by a factor of at least 50. Our study will impact the design of multi-loop atom interferometers that measure a single inertial quantity.
△ Less
Submitted 23 November, 2020; v1 submitted 15 June, 2020;
originally announced June 2020.
-
High-accuracy inertial measurements with cold-atom sensors
Authors:
Remi Geiger,
Arnaud Landragin,
Sébastien Merlet,
Franck Pereira Dos Santos
Abstract:
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review present…
▽ More
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. It then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications, and on the latest directions of research.
△ Less
Submitted 27 March, 2020;
originally announced March 2020.
-
Accurate trajectory alignment in cold-atom interferometers with separated laser beams
Authors:
M. Altorio,
L. A. Sidorenkov,
R. Gautier,
D. Savoie,
A. Landragin,
R. Geiger
Abstract:
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wave front of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the…
▽ More
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wave front of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the effect of a coupling between the relative alignment of two separated laser beams and the trajectory of the atomic wave packet in a four-light-pulse cold-atom gyroscope operated in fountain configuration. We present a method to align the two laser beams at the $0.2 \ μ$rad level and to determine the optimal mean velocity of the atomic wave packet with an accuracy of $0.2\ \textrm{mm}\cdot\textrm{s}^{-1}$. Such fine tuning constrains the associated gyroscope bias to a level of $1\times 10^{-10}~\textrm{rad}\cdot\textrm{s}^{-1}$. In addition, we reveal this coupling using the point-source interferometry technique by analyzing single-shot time-of-flight fluorescence traces, which allows us to measure large angular misalignments between the interrogation beams. The alignment method which we present here can be employed in other sensor configurations and is particularly relevant to emerging gravitational wave detector concepts based on cold-atom interferometry.
△ Less
Submitted 12 March, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
All-Optical Bose-Einstein Condensates in Microgravity
Authors:
Gabriel Condon,
Martin Rabault,
Brynle Barrett,
Laure Chichet,
Romain Arguel,
Hodei Eneriz-Imaz,
Devang Naik,
Andrea Bertoldi,
Baptiste Battelier,
Arnaud Landragin,
Philippe Bouyer
Abstract:
We report on the all-optical production of Bose-Einstein condensates in microgravity using a combination of grey molasses cooling, light-shift engineering and optical trapping in a painted potential. Forced evaporative cooling in a 3-m high Einstein elevator results in $4 \times 10^4$ condensed atoms every 13.5 s, with a temperature as low as 35 nK. In this system, the atomic cloud can expand in w…
▽ More
We report on the all-optical production of Bose-Einstein condensates in microgravity using a combination of grey molasses cooling, light-shift engineering and optical trapping in a painted potential. Forced evaporative cooling in a 3-m high Einstein elevator results in $4 \times 10^4$ condensed atoms every 13.5 s, with a temperature as low as 35 nK. In this system, the atomic cloud can expand in weightlessness for up to 400 ms, paving the way for atom interferometry experiments with extended interrogation times and studies of ultra-cold matter physics at low energies on ground or in Space.
△ Less
Submitted 25 June, 2019; v1 submitted 24 June, 2019;
originally announced June 2019.
-
Interleaved Atom Interferometry for High Sensitivity Inertial Measurements
Authors:
D. Savoie,
M. Altorio,
B. Fang,
L. A. Sidorenkov,
R. Geiger,
A. Landragin
Abstract:
Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interf…
▽ More
Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynamic rotation measurements in a so-far unexplored range. We demonstrate a stability of $3\times 10^{-10}$ rad.s$^{-1}$, which competes with the best stability levels obtained with fiber-optics gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity-gradiometry, searches for dark matter, or gravitational wave detection.
△ Less
Submitted 8 January, 2019; v1 submitted 31 August, 2018;
originally announced August 2018.
-
Atom Interferometry with Top-Hat Laser Beams
Authors:
N. Mielec,
M. Altorio,
R. Sapam,
D. Horville,
D. Holleville,
L. A. Sidorenkov,
A. Landragin,
R. Geiger
Abstract:
The uniformity of the intensity and phase of laser beams is crucial to high-performance atom interferometers. Inhomogeneities in the laser intensity profile cause contrast reductions and systematic effects in interferometers operated with atom sources at micro-Kelvin temperatures, and detrimental diffraction phase shifts in interferometers using large momentum transfer beam splitters. We report on…
▽ More
The uniformity of the intensity and phase of laser beams is crucial to high-performance atom interferometers. Inhomogeneities in the laser intensity profile cause contrast reductions and systematic effects in interferometers operated with atom sources at micro-Kelvin temperatures, and detrimental diffraction phase shifts in interferometers using large momentum transfer beam splitters. We report on the implementation of a so-called top-hat laser beam in a long-interrogation-time cold-atom interferometer to overcome the issue of the inhomogeneous laser intensity encountered when using Gaussian laser beams. We characterize the intensity and relative phase profiles of the top-hat beam and demonstrate its gain in atom-optics efficiency over a Gaussian beam, in agreement with numerical simulations. We discuss the application of top-hat beams to improve the performance of different architectures of atom interferometers.
△ Less
Submitted 8 November, 2018; v1 submitted 9 August, 2018;
originally announced August 2018.
-
Improving the phase response of an atom interferometer by means of temporal pulse shaping
Authors:
Bess Fang,
Nicolas Mielec,
Denis Savoie,
Matteo Altorio,
Arnaud Landragin,
Remi Geiger
Abstract:
We study theoretically and experimentally the influence of temporally shaping the light pulses in an atom interferometer, with a focus on the phase response of the interferometer. We show that smooth light pulse shapes allow rejecting high frequency phase fluctuations (above the Rabi frequency) and thus relax the requirements on the phase noise or frequency noise of the interrogation lasers drivin…
▽ More
We study theoretically and experimentally the influence of temporally shaping the light pulses in an atom interferometer, with a focus on the phase response of the interferometer. We show that smooth light pulse shapes allow rejecting high frequency phase fluctuations (above the Rabi frequency) and thus relax the requirements on the phase noise or frequency noise of the interrogation lasers driving the interferometer. The light pulse shape is also shown to modify the scale factor of the interferometer, which has to be taken into account in the evaluation of its accuracy budget. We discuss the trade-offs to operate when choosing a particular pulse shape, by taking into account phase noise rejection, velocity selectivity, and applicability to large momentum transfer atom interferometry.
△ Less
Submitted 21 December, 2017;
originally announced December 2017.
-
Generation of high-purity, low-temperature samples of $^{39}$K for applications in metrology
Authors:
L. Antoni-Micollier,
B. Barrett,
L. Chichet,
G. Condon,
B. Battelier,
A. Landragin,
P. Bouyer
Abstract:
We present an all optical technique to prepare a sample of $^{39}$K in a magnetically-insensitive state with 95\% purity while maintaining a temperature of 6 $μ$K. This versatile preparation scheme is particularly well suited to performing matter-wave interferometry with species exhibiting closely-separated hyperfine levels, such as the isotopes of lithium and potassium, and opens new possibilitie…
▽ More
We present an all optical technique to prepare a sample of $^{39}$K in a magnetically-insensitive state with 95\% purity while maintaining a temperature of 6 $μ$K. This versatile preparation scheme is particularly well suited to performing matter-wave interferometry with species exhibiting closely-separated hyperfine levels, such as the isotopes of lithium and potassium, and opens new possibilities for metrology with these atoms. We demonstrate the feasibility of such measurements by realizing an atomic gravimeter and a Ramsey-type spectrometer, both of which exhibit a state-of-the-art sensitivity for cold potassium.
△ Less
Submitted 13 July, 2017;
originally announced July 2017.
-
Studies of general relativity with quantum sensors
Authors:
G. Lefevre,
G. Condon,
I. Riou,
L. Chichet,
M. Essayeh,
M. Rabault,
L. Antoni-Micollier,
N. Mielec,
D. Holleville,
L. Amand,
R. Geiger,
A. Landragin,
M. Prevedelli,
B. Barrett,
B. Battelier,
A. Bertoldi,
B. Canuel,
P. Bouyer
Abstract:
We present two projects aiming to probe key aspects of the theory of General Relativity with high-precision quantum sensors. These projects use cold-atom interferometry with the aim of measuring gravitational waves and testing the equivalence principle. To detect gravitational waves, a large multi-sensor demonstrator is currently under construction that will exploit correlations between three atom…
▽ More
We present two projects aiming to probe key aspects of the theory of General Relativity with high-precision quantum sensors. These projects use cold-atom interferometry with the aim of measuring gravitational waves and testing the equivalence principle. To detect gravitational waves, a large multi-sensor demonstrator is currently under construction that will exploit correlations between three atom interferometers spread along a 200 m optical cavity. Similarly, a test of the weak equivalence principle is currently underway using a compact and mobile dual-species interferometer, which will serve as a prototype for future high-precision tests onboard an orbiting satellite. We present recent results and improvements related to both projects.
△ Less
Submitted 30 May, 2017;
originally announced May 2017.
-
Dual Matter-Wave Inertial Sensors in Weightlessness
Authors:
Brynle Barrett,
Laura Antoni-Micollier,
Laure Chichet,
Baptiste Battelier,
Thomas Lévèque,
Arnaud Landragin,
Philippe Bouyer
Abstract:
Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the best precision achievable on Earth is limited by the free-fall time of the atoms, and their full potential can only be realized in Space where interrogation times of many seconds will lead to unprecedented sensitivity. Various mission scenarios ar…
▽ More
Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the best precision achievable on Earth is limited by the free-fall time of the atoms, and their full potential can only be realized in Space where interrogation times of many seconds will lead to unprecedented sensitivity. Various mission scenarios are presently being pursued which plan to implement matter-wave inertial sensors. Toward this goal, we realize the first onboard operation of simultaneous $^{87}$Rb $-$ $^{39}$K interferometers in the weightless environment produced during parabolic flight. The large vibration levels ($10^{-2}~g/\sqrt{\rm Hz}$), acceleration range ($0-1.8~g$) and rotation rates ($5$ deg/s) during flight present significant challenges. We demonstrate the capability of our dual-quantum sensor by measuring the Eötvös parameter with systematic-limited uncertainties of $1.1 \times 10^{-3}$ and $3.0 \times 10^{-4}$ during standard- and micro-gravity, respectively. This constitutes the first test of the equivalence principle in a free-falling vehicle with quantum sensors. Our results are applicable to inertial navigation, and can be extended to the trajectory of a satellite for future Space missions.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Correlative methods for dual-species quantum tests of the weak equivalence principle
Authors:
B. Barrett,
L. Antoni-Micollier,
L. Chichet,
B. Battelier,
P. -A. Gominet,
A. Bertoldi,
P. Bouyer,
A. Landragin
Abstract:
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interf…
▽ More
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle. The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous $^{87}$Rb and $^{39}$K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the weak equivalence principle with a sensitivity of $1.6 \times 10^{-6}$ per measurement with an interrogation time of $T = 10$ ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
△ Less
Submitted 11 August, 2015; v1 submitted 29 March, 2015;
originally announced March 2015.
-
Stability enhancement by joint phase measurements in a single cold atomic fountain
Authors:
M. Meunier,
I. Dutta,
R. Geiger,
C. Guerlin,
C. L. Garrido Alzar,
A. Landragin
Abstract:
We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows achieving the lowest st…
▽ More
We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows achieving the lowest stability limit due to atom shot noise. We demonstrate a multiple joint operation in which up to five clouds of atoms are interrogated simultaneously in a single setup. The essential feature of multiple joint operation, demonstrated here for a micro-wave Ramsey interrogation, can be generalized to go beyond the current stability limit associated with dead times in present-day cold atom interferometer inertial sensors.
△ Less
Submitted 8 January, 2015;
originally announced January 2015.
-
Design of a dual species atom interferometer for space
Authors:
Thilo Schuldt,
Christian Schubert,
Markus Krutzik,
Lluis Gesa Bote,
Naceur Gaaloul,
Jonas Hartwig,
Holger Ahlers,
Waldemar Herr,
Katerine Posso-Trujillo,
Jan Rudolph,
Stephan Seidel,
Thijs Wendrich,
Wolfgang Ertmer,
Sven Herrmann,
André Kubelka-Lange,
Alexander Milke,
Benny Rievers,
Emanuele Rocco,
Andrew Hinton,
Kai Bongs,
Markus Oswald,
Matthias Franz,
Matthias Hauth,
Achim Peters,
Ahmad Bawamia
, et al. (32 additional authors not shown)
Abstract:
Atom interferometers have a multitude of proposed applications in space including precise measurements of the Earth's gravitational field, in navigation & ranging, and in fundamental physics such as tests of the weak equivalence principle (WEP) and gravitational wave detection. While atom interferometers are realized routinely in ground-based laboratories, current efforts aim at the development of…
▽ More
Atom interferometers have a multitude of proposed applications in space including precise measurements of the Earth's gravitational field, in navigation & ranging, and in fundamental physics such as tests of the weak equivalence principle (WEP) and gravitational wave detection. While atom interferometers are realized routinely in ground-based laboratories, current efforts aim at the development of a space compatible design optimized with respect to dimensions, weight, power consumption, mechanical robustness and radiation hardness. In this paper, we present a design of a high-sensitivity differential dual species $^{85}$Rb/$^{87}$Rb atom interferometer for space, including physics package, laser system, electronics and software. The physics package comprises the atom source consisting of dispensers and a 2D magneto-optical trap (MOT), the science chamber with a 3D-MOT, a magnetic trap based on an atom chip and an optical dipole trap (ODT) used for Bose-Einstein condensate (BEC) creation and interferometry, the detection unit, the vacuum system for $10^{-11}$ mbar ultra-high vacuum generation, and the high-suppression factor magnetic shielding as well as the thermal control system. The laser system is based on a hybrid approach using fiber-based telecom components and high-power laser diode technology and includes all laser sources for 2D-MOT, 3D-MOT, ODT, interferometry and detection. Manipulation and switching of the laser beams is carried out on an optical bench using Zerodur bonding technology. The instrument consists of 9 units with an overall mass of 221 kg, an average power consumption of 608 W (819 W peak), and a volume of 470 liters which would well fit on a satellite to be launched with a Soyuz rocket, as system studies have shown.
△ Less
Submitted 8 December, 2014;
originally announced December 2014.
-
The Sagnac effect: 20 years of development in matter-wave interferometry
Authors:
Brynle Barrett,
Remi Geiger,
Indranil Dutta,
Matthieu Meunier,
Benjamin Canuel,
Alexandre Gauguet,
Philippe Bouyer,
Arnaud Landragin
Abstract:
Since the first atom interferometry experiments in 1991, measurements of rotation through the Sagnac effect in open-area atom interferometers has been studied. These studies have demonstrated very high sensitivity which can compete with state-of-the-art optical Sagnac interferometers. Since the early 2000s, these developments have been motivated by possible applications in inertial guidance and ge…
▽ More
Since the first atom interferometry experiments in 1991, measurements of rotation through the Sagnac effect in open-area atom interferometers has been studied. These studies have demonstrated very high sensitivity which can compete with state-of-the-art optical Sagnac interferometers. Since the early 2000s, these developments have been motivated by possible applications in inertial guidance and geophysics. Most matter-wave interferometers that have been investigated since then are based on two-photon Raman transitions for the manipulation of atomic wave packets. Results from the two most studied configurations, a space-domain interferometer with atomic beams and a time-domain interferometer with cold atoms, are presented and compared. Finally, the latest generation of cold atom interferometers and their preliminary results are presented.
△ Less
Submitted 1 December, 2014;
originally announced December 2014.
-
Hybridizing matter-wave and classical accelerometers
Authors:
Jean Lautier,
Laurent Volodimer,
Thomas Hardin,
Sebastien Merlet,
Michel Lours,
Franck Pereira Dos Santos,
Arnaud Landragin
Abstract:
We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC com…
▽ More
We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely the dead times between consecutive measurements.
△ Less
Submitted 6 October, 2014; v1 submitted 30 September, 2014;
originally announced October 2014.
-
A compact micro-wave synthesizer for transportable cold-atom interferometers
Authors:
Jean Lautier,
Michel Lours,
Arnaud Landragin
Abstract:
We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of Rubidium 87 atoms at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references…
▽ More
We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of Rubidium 87 atoms at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references developed at LNE-SYRTE. In free-running mode, it features a residual phase noise level of -65 dBrad$^2.Hz^{-1} at 10-Hz offset frequency and a white phase noise level in the order of -120 dBrad^2.Hz^{-1} for Fourier frequencies above 10 kHz. The phase noise effect on the sensitivity of the atomic interferometer is evaluated for diverse values of cycling time, interrogation time and Raman pulse duration. To our knowledge, the resulting contribution is well below the sensitivity of any demonstrated cold atom inertial sensors based on stimulated Raman transitions. The drastic improvement in terms of size, simplicity and power consumption paves the way towards field and mobile operations.
△ Less
Submitted 11 June, 2014;
originally announced June 2014.
-
Feedback control of coherent spin states using weak nondestructive measurements
Authors:
Thomas Vanderbruggen,
Ralf Kohlhaas,
Andrea Bertoldi,
Etienne Cantin,
Arnaud Landragin,
Philippe Bouyer
Abstract:
We consider the decoherence of a pseudo-spin ensemble under collective random rotations, and study, both theoretically and experimentally, how a nondestructive measurement combined with real-time feedback correction can protect the state against such a decoherence process. We theoretically characterize the feedback efficiency with different parameters --- coherence, entropy, fidelity --- and show…
▽ More
We consider the decoherence of a pseudo-spin ensemble under collective random rotations, and study, both theoretically and experimentally, how a nondestructive measurement combined with real-time feedback correction can protect the state against such a decoherence process. We theoretically characterize the feedback efficiency with different parameters --- coherence, entropy, fidelity --- and show that a maximum efficiency is reached in the weak measurement regime, when the projection of the state induced by the measurement is negligible. This article presents in detail the experimental results published in [Phys. Rev. Lett. \textbf{110}, 210503 (2013)], where the feedback scheme stabilizes coherent spin states of trapped ultra-cold atoms, and nondestructively probed with a dispersive optical detection. In addition, we study the influence of several parameters, such as atom number and rotation angle, on the performance of the method. We analyze the various decoherence sources limiting the feedback efficiency and propose how to mitigate their effect. The results demonstrate the potential of the method for the real-time coherent control of atom interferometers.
△ Less
Submitted 19 May, 2014;
originally announced May 2014.
-
Quantum Tests of the Einstein Equivalence Principle with the STE-QUEST Space Mission
Authors:
Brett Altschul,
Quentin G. Bailey,
Luc Blanchet,
Kai Bongs,
Philippe Bouyer,
Luigi Cacciapuoti,
Salvatore Capozziello,
Naceur Gaaloul,
Domenico Giulini,
Jonas Hartwig,
Luciano Iess,
Philippe Jetzer,
Arnaud Landragin,
Ernst Rasel,
Serge Reynaud,
Stephan Schiller,
Christian Schubert,
Fiodor Sorrentino,
Uwe Sterr,
Jay D. Tasson,
Guglielmo M. Tino,
Philip Tuckey,
Peter Wolf
Abstract:
We present in detail the scientific objectives in fundamental physics of the Space-Time Explorer and QUantum Equivalence Space Test (STE-QUEST) space mission. STE-QUEST was pre-selected by the European Space Agency together with four other missions for the cosmic vision M3 launch opportunity planned around 2024. It carries out tests of different aspects of the Einstein Equivalence Principle using…
▽ More
We present in detail the scientific objectives in fundamental physics of the Space-Time Explorer and QUantum Equivalence Space Test (STE-QUEST) space mission. STE-QUEST was pre-selected by the European Space Agency together with four other missions for the cosmic vision M3 launch opportunity planned around 2024. It carries out tests of different aspects of the Einstein Equivalence Principle using atomic clocks, matter wave interferometry and long distance time/frequency links, providing fascinating science at the interface between quantum mechanics and gravitation that cannot be achieved, at that level of precision, in ground experiments. We especially emphasize the specific strong interest of performing equivalence principle tests in the quantum regime, i.e. using quantum atomic wave interferometry. Although STE-QUEST was finally not selected in early 2014 because of budgetary and technological reasons, its science case was very highly rated. Our aim is to expose that science to a large audience in order to allow future projects and proposals to take advantage of the STE-QUEST experience.
△ Less
Submitted 25 September, 2014; v1 submitted 16 April, 2014;
originally announced April 2014.
-
STE-QUEST - Test of the Universality of Free Fall Using Cold Atom Interferometry
Authors:
D. Aguilera,
H. Ahlers,
B. Battelier,
A. Bawamia,
A. Bertoldi,
R. Bondarescu,
K. Bongs,
P. Bouyer,
C. Braxmaier,
L. Cacciapuoti,
C. Chaloner,
M. Chwalla,
W. Ertmer,
M. Franz,
N. Gaaloul,
M. Gehler,
D. Gerardi,
L. Gesa,
N. Gürlebeck,
J. Hartwig,
M. Hauth,
O. Hellmig,
W. Herr,
S. Herrmann,
A. Heske
, et al. (41 additional authors not shown)
Abstract:
The theory of general relativity describes macroscopic phenomena driven by the influence of gravity while quantum mechanics brilliantly accounts for microscopic effects. Despite their tremendous individual success, a complete unification of fundamental interactions is missing and remains one of the most challenging and important quests in modern theoretical physics. The STE-QUEST satellite mission…
▽ More
The theory of general relativity describes macroscopic phenomena driven by the influence of gravity while quantum mechanics brilliantly accounts for microscopic effects. Despite their tremendous individual success, a complete unification of fundamental interactions is missing and remains one of the most challenging and important quests in modern theoretical physics. The STE-QUEST satellite mission, proposed as a medium-size mission within the Cosmic Vision program of the European Space Agency (ESA), aims for testing general relativity with high precision in two experiments by performing a measurement of the gravitational redshift of the Sun and the Moon by comparing terrestrial clocks, and by performing a test of the Universality of Free Fall of matter waves in the gravitational field of Earth comparing the trajectory of two Bose-Einstein condensates of Rb85 and Rb87. The two ultracold atom clouds are monitored very precisely thanks to techniques of atom interferometry. This allows to reach down to an uncertainty in the Eötvös parameter of at least 2x10E-15. In this paper, we report about the results of the phase A mission study of the atom interferometer instrument covering the description of the main payload elements, the atomic source concept, and the systematic error sources.
△ Less
Submitted 14 April, 2014; v1 submitted 20 December, 2013;
originally announced December 2013.
-
Differential atom interferometry with $^{87}$Rb and $^{85}$Rb for testing the UFF in STE-QUEST
Authors:
C Schubert,
J Hartwig,
H Ahlers,
K Posso-Trujillo,
N. Gaaloul,
U. Velte,
A. Landragin,
A. Bertoldi,
B. Battelier,
P. Bouyer,
F. Sorrentino,
G. M. Tino,
M. Krutzik,
A. Peters,
S. Herrmann,
C. Lämmerzahl,
L. Cacciapouti,
E. Rocco,
K. Bongs,
W. Ertmer,
E. M. Rasel
Abstract:
In this paper we discuss in detail an experimental scheme to test the universality of free fall (UFF) with a differential $^{87}$Rb / $^{85}$Rb atom interferometer applicable for extended free fall of several seconds in the frame of the STE-QUEST mission. This analysis focuses on suppression of noise and error sources which would limit the accuracy of a violation measurement. We show that the choi…
▽ More
In this paper we discuss in detail an experimental scheme to test the universality of free fall (UFF) with a differential $^{87}$Rb / $^{85}$Rb atom interferometer applicable for extended free fall of several seconds in the frame of the STE-QUEST mission. This analysis focuses on suppression of noise and error sources which would limit the accuracy of a violation measurement. We show that the choice of atomic species and the correctly matched parameters of the interferometer sequence are of utmost importance to suppress leading order phase shifts. In conclusion we will show the expected performance of $2$ parts in $10^{15}$ of such an interferometer for a test of the UFF.
△ Less
Submitted 20 December, 2013;
originally announced December 2013.
-
Feedback control of trapped coherent atomic ensembles
Authors:
T. Vanderbruggen,
R. Kohlhaas,
A. Bertoldi,
S. Bernon,
A. Aspect,
A. Landragin,
P. Bouyer
Abstract:
We demonstrate how to use feedback to control the internal states of trapped coherent ensembles of two-level atoms, and to protect a superposition state against the decoherence induced by a collective noise. Our feedback scheme is based on weak optical measurements with negligible back-action and coherent microwave manipulations. The efficiency of the feedback system is studied for a simple binary…
▽ More
We demonstrate how to use feedback to control the internal states of trapped coherent ensembles of two-level atoms, and to protect a superposition state against the decoherence induced by a collective noise. Our feedback scheme is based on weak optical measurements with negligible back-action and coherent microwave manipulations. The efficiency of the feedback system is studied for a simple binary noise model and characterized in terms of the trade-off between information retrieval and destructivity from the optical probe. We also demonstrate the correction of more general types of collective noise. This technique can be used for the operation of atomic interferometers beyond the standard Ramsey scheme, opening the way towards improved atomic sensors.
△ Less
Submitted 23 April, 2013; v1 submitted 13 July, 2012;
originally announced July 2012.
-
Detecting inertial effects with airborne matter-wave interferometry
Authors:
Remi Geiger,
Vincent Ménoret,
Guillaume Stern,
Nassim Zahzam,
Patrick Cheinet,
Baptiste Battelier,
André Villing,
Frédéric Moron,
Michel Lours,
Yannick Bidel,
Alexandre Bresson,
Arnaud Landragin,
Philippe Bouyer
Abstract:
Inertial sensors relying on atom interferometry offer a breakthrough advance in a variety of applications, such as inertial navigation, gravimetry or ground- and space-based tests of fundamental physics. These instruments require a quiet environment to reach their performance and using them outside the laboratory remains a challenge. Here we report the first operation of an airborne matter-wave ac…
▽ More
Inertial sensors relying on atom interferometry offer a breakthrough advance in a variety of applications, such as inertial navigation, gravimetry or ground- and space-based tests of fundamental physics. These instruments require a quiet environment to reach their performance and using them outside the laboratory remains a challenge. Here we report the first operation of an airborne matter-wave accelerometer set up aboard a 0g plane and operating during the standard gravity (1g) and microgravity (0g) phases of the flight. At 1g, the sensor can detect inertial effects more than 300 times weaker than the typical acceleration fluctuations of the aircraft. We describe the improvement of the interferometer sensitivity in 0g, which reaches 2 x 10-4 ms-2 / \surdHz with our current setup. We finally discuss the extension of our method to airborne and spaceborne tests of the Universality of free fall with matter waves.
△ Less
Submitted 27 September, 2011;
originally announced September 2011.
-
Heterodyne non-demolition measurements on cold atomic samples: towards the preparation of non-classical states for atom interferometry
Authors:
Simon Bernon,
Thomas Vanderbruggen,
Ralf Kohlhaas,
Andrea Bertoldi,
Arnaud Landragin,
Philippe Bouyer
Abstract:
We report on a novel experiment to generate non-classical atomic states via quantum non-demolition (QND) measurements on cold atomic samples prepared in a high finesse ring cavity. The heterodyne technique developed for the QND detection exhibits an optical shot-noise limited behavior for local oscillator optical power of a few hundred \muW, and a detection bandwidth of several GHz. This detection…
▽ More
We report on a novel experiment to generate non-classical atomic states via quantum non-demolition (QND) measurements on cold atomic samples prepared in a high finesse ring cavity. The heterodyne technique developed for the QND detection exhibits an optical shot-noise limited behavior for local oscillator optical power of a few hundred \muW, and a detection bandwidth of several GHz. This detection tool is used in single pass to follow non destructively the internal state evolution of an atomic sample when subjected to Rabi oscillations or a spin-echo interferometric sequence.
△ Less
Submitted 29 June, 2011; v1 submitted 9 March, 2011;
originally announced March 2011.
-
Spin-squeezing and Dicke state preparation by heterodyne measurement
Authors:
Thomas Vanderbruggen,
Simon Bernon,
Andréa Bertoldi,
Arnaud Landragin,
Philippe Bouyer
Abstract:
We investigate the quantum non-demolition (QND) measurement of an atomic population based on a heterodyne detection and show that the induced back-action allows to prepare both spin-squeezed and Dicke states. We use a wavevector formalism to describe the stochastic process of the measurement and the associated atomic evolution. Analytical formulas of the atomic distribution momenta are derived in…
▽ More
We investigate the quantum non-demolition (QND) measurement of an atomic population based on a heterodyne detection and show that the induced back-action allows to prepare both spin-squeezed and Dicke states. We use a wavevector formalism to describe the stochastic process of the measurement and the associated atomic evolution. Analytical formulas of the atomic distribution momenta are derived in the weak coupling regime both for short and long time behavior, and they are in good agreement with those obtained by a Monte-Carlo simulation. The experimental implementation of the proposed heterodyne detection scheme is discussed. The role played in the squeezing process by the spontaneous emission is considered.
△ Less
Submitted 25 November, 2010; v1 submitted 28 February, 2010;
originally announced March 2010.
-
Quantum Physics Exploring Gravity in the Outer Solar System: The Sagas Project
Authors:
P. Wolf,
Ch. J. Bordé,
A. Clairon,
L. Duchayne,
A. Landragin,
P. Lemonde,
G. Santarelli,
W. Ertmer,
E. Rasel,
F. S. Cataliotti,
M. Inguscio,
G. M. Tino,
P. Gill,
H. Klein,
S. Reynaud,
C. Salomon,
E. Peik,
O. Bertolami,
P. Gil,
J. Páramos,
C. Jentsch,
U. Johann,
A. Rathke,
P. Bouyer,
L. Cacciapuoti
, et al. (30 additional authors not shown)
Abstract:
We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to…
▽ More
We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to 2030 time-frame. SAGAS has numerous science objectives in fundamental physics and Solar System science, for example numerous tests of general relativity and the exploration of the Kuiper belt. The combination of highly sensitive atomic sensors and of the laser link well adapted for large distances will allow measurements with unprecedented accuracy and on scales never reached before. We present the proposed mission in some detail, with particular emphasis on the science goals and associated measurements.
△ Less
Submitted 12 August, 2008; v1 submitted 2 November, 2007;
originally announced November 2007.