-
High-fidelity holographic beam shaping with optimal transport and phase diversity
Authors:
Hunter Swan,
Andrii Torchylo,
Michael J. Van de Graaff,
Jan Rudolph,
Jason M. Hogan
Abstract:
A phase-only spatial light modulator (SLM) provides a powerful way to shape laser beams into arbitrary intensity patterns, but at the cost of a hard computational problem of determining an appropriate SLM phase. Here we show that optimal transport methods can generate approximate solutions to this problem that serve as excellent initializations for iterative phase retrieval algorithms, yielding vo…
▽ More
A phase-only spatial light modulator (SLM) provides a powerful way to shape laser beams into arbitrary intensity patterns, but at the cost of a hard computational problem of determining an appropriate SLM phase. Here we show that optimal transport methods can generate approximate solutions to this problem that serve as excellent initializations for iterative phase retrieval algorithms, yielding vortex-free solutions with superior accuracy and efficiency. Additionally, we show that analogous algorithms can be used to measure the intensity and phase of the input beam incident upon the SLM via phase diversity imaging. These techniques furnish flexible and convenient solutions to the computational challenges of beam shaping with an SLM.
△ Less
Submitted 30 August, 2024;
originally announced August 2024.
-
Collinear three-photon excitation of a strongly forbidden optical clock transition
Authors:
Samuel P. Carman,
Jan Rudolph,
Benjamin E. Garber,
Michael J. Van de Graaff,
Hunter Swan,
Yijun Jiang,
Megan Nantel,
Mahiro Abe,
Rachel L. Barcklay,
Jason M. Hogan
Abstract:
The ${{^1\mathrm{S}_0}\!-\!{^3\mathrm{P}_0}}$ clock transition in strontium serves as the foundation for the world's best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope $^{87}$Sr but strongly forbidden in bosonic isotopes. Here we demonstrate coherent excitation of the clock transition in bosonic…
▽ More
The ${{^1\mathrm{S}_0}\!-\!{^3\mathrm{P}_0}}$ clock transition in strontium serves as the foundation for the world's best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope $^{87}$Sr but strongly forbidden in bosonic isotopes. Here we demonstrate coherent excitation of the clock transition in bosonic ${}^{88}$Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to $50~\text{kHz}$ using $\text{W}/\text{cm}^{2}$ laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.
△ Less
Submitted 27 June, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Novel Light Field Imaging Device with Enhanced Light Collection for Cold Atom Clouds
Authors:
Sanha Cheong,
Josef C. Frisch,
Sean Gasiorowski,
Jason M. Hogan,
Michael Kagan,
Murtaza Safdari,
Ariel Schwartzman,
Maxime Vandegar
Abstract:
We present a light field imaging system that captures multiple views of an object with a single shot. The system is designed to maximize the total light collection by accepting a larger solid angle of light than a conventional lens with equivalent depth of field. This is achieved by populating a plane of virtual objects using mirrors and fully utilizing the available field of view and depth of fie…
▽ More
We present a light field imaging system that captures multiple views of an object with a single shot. The system is designed to maximize the total light collection by accepting a larger solid angle of light than a conventional lens with equivalent depth of field. This is achieved by populating a plane of virtual objects using mirrors and fully utilizing the available field of view and depth of field. Simulation results demonstrate that this design is capable of single-shot tomography of objects of size $\mathcal{O}$(1 mm$^3$), reconstructing the 3-dimensional (3D) distribution and features not accessible from any single view angle in isolation. In particular, for atom clouds used in atom interferometry experiments, the system can reconstruct 3D fringe patterns with size $\mathcal{O}$(100 $μ$m). We also demonstrate this system with a 3D-printed prototype. The prototype is used to take images of $\mathcal{O}$(1 mm$^{3}$) sized objects, and 3D reconstruction algorithms running on a single-shot image successfully reconstruct $\mathcal{O}$(100 $μ$m) internal features. The prototype also shows that the system can be built with 3D printing technology and hence can be deployed quickly and cost-effectively in experiments with needs for enhanced light collection or 3D reconstruction. Imaging of cold atom clouds in atom interferometry is a key application of this new type of imaging device where enhanced light collection, high depth of field, and 3D tomographic reconstruction can provide new handles to characterize the atom clouds.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Atom Interferometry with Floquet Atom Optics
Authors:
Thomas Wilkason,
Megan Nantel,
Jan Rudolph,
Yijun Jiang,
Benjamin E. Garber,
Hunter Swan,
Samuel P. Carman,
Mahiro Abe,
Jason M. Hogan
Abstract:
Floquet engineering offers a compelling approach for designing the time evolution of periodically driven systems. We implement a periodic atom-light coupling to realize Floquet atom optics on the strontium ${}^1\!S_0\,\text{-}\, {}^3\!P_1$ transition. These atom optics reach pulse efficiencies above $99.4\%$ over a wide range of frequency offsets between light and atomic resonance, even under stro…
▽ More
Floquet engineering offers a compelling approach for designing the time evolution of periodically driven systems. We implement a periodic atom-light coupling to realize Floquet atom optics on the strontium ${}^1\!S_0\,\text{-}\, {}^3\!P_1$ transition. These atom optics reach pulse efficiencies above $99.4\%$ over a wide range of frequency offsets between light and atomic resonance, even under strong driving where this detuning is on the order of the Rabi frequency. Moreover, we use Floquet atom optics to compensate for differential Doppler shifts in large momentum transfer atom interferometers and achieve state-of-the-art momentum separation in excess of $400~\hbar k$. This technique can be applied to any two-level system at arbitrary coupling strength, with broad application in coherent quantum control.
△ Less
Submitted 17 January, 2023; v1 submitted 14 May, 2022;
originally announced May 2022.
-
Large Momentum Transfer Clock Atom Interferometry on the 689 nm Intercombination Line of Strontium
Authors:
Jan Rudolph,
Thomas Wilkason,
Megan Nantel,
Hunter Swan,
Connor M. Holland,
Yijun Jiang,
Benjamin E. Garber,
Samuel P. Carman,
Jason M. Hogan
Abstract:
We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium ${}^1S_0 - {}^3P_1$ transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to $141\,\hbar k$ and gradiometers of up to $81\,\hbar k$. Moreover, we circumvent excited state decay limitations and extend the grad…
▽ More
We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium ${}^1S_0 - {}^3P_1$ transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to $141\,\hbar k$ and gradiometers of up to $81\,\hbar k$. Moreover, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of $3\,μ\text{K}$. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.
△ Less
Submitted 2 March, 2020; v1 submitted 11 October, 2019;
originally announced October 2019.
-
SAGE: A Proposal for a Space Atomic Gravity Explorer
Authors:
G. M. Tino,
A. Bassi,
G. Bianco,
K. Bongs,
P. Bouyer,
L. Cacciapuoti,
S. Capozziello,
X. Chen,
M. L. Chiofalo,
A. Derevianko,
W. Ertmer,
N. Gaaloul,
P. Gill,
P. W. Graham,
J. M. Hogan,
L. Iess,
M. A. Kasevich,
H. Katori,
C. Klempt,
X. Lu,
L. -S. Ma,
H. Müller,
N. R. Newbury,
C. Oates,
A. Peters
, et al. (22 additional authors not shown)
Abstract:
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
△ Less
Submitted 18 November, 2019; v1 submitted 8 July, 2019;
originally announced July 2019.
-
Atomic source selection in space-borne gravitational wave detection
Authors:
S Loriani,
D Schlippert,
C Schubert,
S Abend,
H Ahlers,
W Ertmer,
J Rudolph,
J M Hogan,
M A Kasevich,
E M Rasel,
N Gaaloul
Abstract:
Recent proposals for space-borne gravitational wave detectors based on atom interferometry rely on extremely narrow single-photon transition lines as featured by alkaline-earth metals or atomic species with similar electronic configuration. Despite their similarity, these species differ in key parameters such as abundance of isotopes, atomic flux, density and temperature regimes, achievable expans…
▽ More
Recent proposals for space-borne gravitational wave detectors based on atom interferometry rely on extremely narrow single-photon transition lines as featured by alkaline-earth metals or atomic species with similar electronic configuration. Despite their similarity, these species differ in key parameters such as abundance of isotopes, atomic flux, density and temperature regimes, achievable expansion rates, density limitations set by interactions, as well as technological and operational requirements. In this study, we compare viable candidates for gravitational wave detection with atom interferometry, contrast the most promising atomic species, identify the relevant technological milestones and investigate potential source concepts towards a future gravitational wave detector in space.
△ Less
Submitted 29 December, 2018;
originally announced December 2018.
-
Effective inertial frame in an atom interferometric test of the equivalence principle
Authors:
Chris Overstreet,
Peter Asenbaum,
Tim Kovachy,
Remy Notermans,
Jason M. Hogan,
Mark A. Kasevich
Abstract:
In an ideal test of the equivalence principle, the test masses fall in a common inertial frame. A real experiment is affected by gravity gradients, which introduce systematic errors by coupling to initial kinematic differences between the test masses. We demonstrate a method that reduces the sensitivity of a dual-species atom interferometer to initial kinematics by using a frequency shift of the m…
▽ More
In an ideal test of the equivalence principle, the test masses fall in a common inertial frame. A real experiment is affected by gravity gradients, which introduce systematic errors by coupling to initial kinematic differences between the test masses. We demonstrate a method that reduces the sensitivity of a dual-species atom interferometer to initial kinematics by using a frequency shift of the mirror pulse to create an effective inertial frame for both atomic species. This suppresses the gravity-gradient-induced dependence of the differential phase on initial kinematic differences by a factor of 100 and enables a precise measurement of these differences. We realize a relative precision of $Δg / g \approx 6 \times 10^{-11}$ per shot, which improves on the best previous result for a dual-species atom interferometer by more than three orders of magnitude. By suppressing gravity gradient systematic errors to below one part in $10^{13}$, these results pave the way for an atomic test of the equivalence principle at an accuracy comparable with state-of-the-art classical tests.
△ Less
Submitted 29 November, 2017; v1 submitted 27 November, 2017;
originally announced November 2017.
-
Phase shift in atom interferometry due to spacetime curvature
Authors:
Peter Asenbaum,
Chris Overstreet,
Tim Kovachy,
Daniel D. Brown,
Jason M. Hogan,
Mark A. Kasevich
Abstract:
We present a single-source dual atom interferometer and utilize it as a gradiometer for precise gravitational measurements. The macroscopic separation between interfering atomic wave packets (as large as 16 cm) reveals the interplay of recoil effects and gravitational curvature from a nearby Pb source mass. The gradiometer baseline is set by the laser wavelength and pulse timings, which can be mea…
▽ More
We present a single-source dual atom interferometer and utilize it as a gradiometer for precise gravitational measurements. The macroscopic separation between interfering atomic wave packets (as large as 16 cm) reveals the interplay of recoil effects and gravitational curvature from a nearby Pb source mass. The gradiometer baseline is set by the laser wavelength and pulse timings, which can be measured to high precision. Using a long drift time and large momentum transfer atom optics, the gradiometer reaches a resolution of $3 \times 10^{-9}$ s$^{-2}$ per shot and measures a 1 rad phase shift induced by the source mass.
△ Less
Submitted 12 October, 2016; v1 submitted 12 October, 2016;
originally announced October 2016.
-
Response to "Verifying quantum superpositions at metre scales"
Authors:
T. Kovachy,
P. Asenbaum,
C. Overstreet,
C. A. Donnelly,
S. M. Dickerson,
A. Sugarbaker,
J. M. Hogan,
M. A. Kasevich
Abstract:
The preceding BCA (Stamper-Kurn et. al., arXiv:1607.01454) asserts that our observation of interference contrast in a half-metre-scale atom interferometer (Kovachy et. al., Nature 528, 530-3 (2015)) does not prove the existence of macroscopic quantum superpositions and hence does not test quantum mechanics at long length scales. Moreover, the BCA implies that intrinsic atomic interactions or techn…
▽ More
The preceding BCA (Stamper-Kurn et. al., arXiv:1607.01454) asserts that our observation of interference contrast in a half-metre-scale atom interferometer (Kovachy et. al., Nature 528, 530-3 (2015)) does not prove the existence of macroscopic quantum superpositions and hence does not test quantum mechanics at long length scales. Moreover, the BCA implies that intrinsic atomic interactions or technical imperfections could prevent the application of our work to future differential measurements. On the contrary, we argue the following: i) in standard quantum mechanics, there is no known mechanism in our system that prohibits its use in future differential measurement applications; ii) our experiment tests quantum mechanics in that it constrains any modifications that would reduce contrast in an interferometer with arms that propagate over widely separated trajectories; and iii) using a standard definition of superposition, our observation of interference results from quantum superposition at the half-metre scale. In particular, quantum superposition is a more general concept than first-order coherence.
△ Less
Submitted 11 July, 2016;
originally announced July 2016.
-
Enhanced atom interferometer readout through the application of phase shear
Authors:
Alex Sugarbaker,
Susannah M. Dickerson,
Jason M. Hogan,
David M. S. Johnson,
Mark A. Kasevich
Abstract:
We present a method for determining the phase and contrast of a single shot of an atom interferometer. The application of a phase shear across the atom ensemble yields a spatially varying fringe pattern at each output port, which can be imaged directly. This method is broadly relevant to atom interferometric precision measurement, as we demonstrate in a 10 m Rb-87 atomic fountain by implementing a…
▽ More
We present a method for determining the phase and contrast of a single shot of an atom interferometer. The application of a phase shear across the atom ensemble yields a spatially varying fringe pattern at each output port, which can be imaged directly. This method is broadly relevant to atom interferometric precision measurement, as we demonstrate in a 10 m Rb-87 atomic fountain by implementing an atom interferometric gyrocompass with 10 millidegree precision.
△ Less
Submitted 14 May, 2013;
originally announced May 2013.
-
Multi-axis inertial sensing with long-time point source atom interferometry
Authors:
Susannah M. Dickerson,
Jason M. Hogan,
Alex Sugarbaker,
David M. S. Johnson,
Mark A. Kasevich
Abstract:
We show that light-pulse atom interferometry with atomic point sources and spatially resolved detection enables multi-axis (two rotation, one acceleration) precision inertial sensing at long interrogation times. Using this method, we demonstrate a light-pulse atom interferometer for Rb-87 with 1.4 cm peak wavepacket separation and a duration of 2T = 2.3 seconds. The inferred acceleration sensitivi…
▽ More
We show that light-pulse atom interferometry with atomic point sources and spatially resolved detection enables multi-axis (two rotation, one acceleration) precision inertial sensing at long interrogation times. Using this method, we demonstrate a light-pulse atom interferometer for Rb-87 with 1.4 cm peak wavepacket separation and a duration of 2T = 2.3 seconds. The inferred acceleration sensitivity of each shot is 6.7 * 10^(-12) g, which improves on previous limits by more than two orders of magnitude. We also measure the Earth's rotation rate with a precision of 200 nrad/s.
△ Less
Submitted 7 May, 2013;
originally announced May 2013.
-
A New Method for Gravitational Wave Detection with Atomic Sensors
Authors:
Peter W. Graham,
Jason M. Hogan,
Mark A. Kasevich,
Surjeet Rajendran
Abstract:
Laser frequency noise is a dominant noise background for the detection of gravitational waves using long-baseline optical interferometry. Amelioration of this noise requires near simultaneous strain measurements on more than one interferometer baseline, necessitating, for example, more than two satellites for a space-based detector, or two interferometer arms for a ground-based detector. We descri…
▽ More
Laser frequency noise is a dominant noise background for the detection of gravitational waves using long-baseline optical interferometry. Amelioration of this noise requires near simultaneous strain measurements on more than one interferometer baseline, necessitating, for example, more than two satellites for a space-based detector, or two interferometer arms for a ground-based detector. We describe a new detection strategy based on recent advances in optical atomic clocks and atom interferometry which can operate at long-baselines and which is immune to laser frequency noise. Laser frequency noise is suppressed because the signal arises strictly from the light propagation time between two ensembles of atoms. This new class of sensor allows sensitive gravitational wave detection with only a single baseline. This approach also has practical applications in, for example, the development of ultra-sensitive gravimeters and gravity gradiometers.
△ Less
Submitted 27 April, 2013; v1 submitted 5 June, 2012;
originally announced June 2012.