-
Imaging transverse modes in a GHz surface acoustic wave cavity
Authors:
M. Fisicaro,
T. A. Steenbergen,
Y. C. Doedes,
K. Heeck,
W. Löffler
Abstract:
Full characterization of surface acoustic wave (SAW) devices requires imaging the spatial distribution of the acoustic field, which is not possible with standard all-electrical measurements where an interdigital transducer (IDT) is used as a detector. Here we present a fiber-based scanning Michelson interferometer employing a strongly focused laser beam as a probe. Combined with a heterodyne circu…
▽ More
Full characterization of surface acoustic wave (SAW) devices requires imaging the spatial distribution of the acoustic field, which is not possible with standard all-electrical measurements where an interdigital transducer (IDT) is used as a detector. Here we present a fiber-based scanning Michelson interferometer employing a strongly focused laser beam as a probe. Combined with a heterodyne circuit, this setup enables frequency- and spatially-resolved measurements of the amplitude and phase of the SAW displacement. We demonstrate this by investigating a 1 GHz SAW cavity, revealing the presence of frequency-overlapping transverse modes, which are not resolved with an all-electrical measurement. The frequency overlap of these transverse modes leads to mode superpositions, which we analyze by quadrature decomposition of the complex acoustic field.
△ Less
Submitted 21 August, 2024;
originally announced August 2024.
-
Coherent Optomechanical State Transfer between Disparate Mechanical Resonators
Authors:
Matthew J. Weaver,
Frank M. Buters,
Fernando Luna,
Hedwig J. Eerkens,
Kier Heeck,
Sven de Man,
Dirk Bouwmeester
Abstract:
Hybrid quantum systems have been developed with various mechanical, optical and microwave harmonic oscillators. The coupling produces a rich library of interactions including two mode squeezing, swapping interactions, back-action evasion and thermal control. In a multimode mechanical system, coupling resonators of different scales (both in frequency and mass) leverages the advantages of each reson…
▽ More
Hybrid quantum systems have been developed with various mechanical, optical and microwave harmonic oscillators. The coupling produces a rich library of interactions including two mode squeezing, swapping interactions, back-action evasion and thermal control. In a multimode mechanical system, coupling resonators of different scales (both in frequency and mass) leverages the advantages of each resonance. For example: a high frequency, easily manipulated resonator could be entangled with a low frequency massive object for tests of gravitational decoherence. Here we demonstrate coherent optomechanical state swapping between two spatially and frequency separated resonators with a mass ratio of 4. We find that, by using two laser beams far detuned from an optical cavity resonance, efficient state transfer is possible through a process very similar to STIRAP (Stimulated Raman Adiabatic Passage) in atomic physics. Although the demonstration is classical, the same technique can be used to generate entanglement between oscillators in the quantum regime.
△ Less
Submitted 7 April, 2017;
originally announced April 2017.
-
Optomechanics with a polarization non-degenerate cavity
Authors:
F. M. Buters,
M. J. Weaver,
H. J. Eerkens,
K. Heeck,
S. de Man,
D. Bouwmeester
Abstract:
Experiments in the field of optomechanics do not yet fully exploit the photon polarization degree of freedom. Here experimental results for an optomechanical interaction in a polarization nondegenerate system are presented and schemes are proposed for how to use this interaction to perform accurate side-band thermometry and to create novel forms of photon-phonon entanglement. The experimental syst…
▽ More
Experiments in the field of optomechanics do not yet fully exploit the photon polarization degree of freedom. Here experimental results for an optomechanical interaction in a polarization nondegenerate system are presented and schemes are proposed for how to use this interaction to perform accurate side-band thermometry and to create novel forms of photon-phonon entanglement. The experimental system utilizes the compressive force in the mirror attached to a mechanical resonator to create a micro-mirror with two radii of curvature which leads, when combined with a second mirror, to a significant polarization splitting of the cavity modes.
△ Less
Submitted 22 June, 2016;
originally announced June 2016.
-
Nested Trampoline Resonators for Optomechanics
Authors:
Matthew J. Weaver,
Brian Pepper,
Fernando Luna,
Frank M. Buters,
Hedwig J. Eerkens,
Gesa Welker,
Blaise Perock,
Kier Heeck,
Sven de Man,
Dirk Bouwmeester
Abstract:
Two major challenges in the development of optomechanical devices are achieving a low mechanical and optical loss rate and vibration isolation from the environment. We address both issues by fabricating trampoline resonators made from low pressure chemical vapor deposition (LPCVD) Si$_3$N$_4$ with a distributed bragg reflector (DBR) mirror. We design a nested double resonator structure with 80 dB…
▽ More
Two major challenges in the development of optomechanical devices are achieving a low mechanical and optical loss rate and vibration isolation from the environment. We address both issues by fabricating trampoline resonators made from low pressure chemical vapor deposition (LPCVD) Si$_3$N$_4$ with a distributed bragg reflector (DBR) mirror. We design a nested double resonator structure with 80 dB of mechanical isolation from the mounting surface at the inner resonator frequency, and we demonstrate up to 45 dB of isolation at lower frequencies in agreement with the design. We reliably fabricate devices with mechanical quality factors of around 400,000 at room temperature. In addition these devices were used to form optical cavities with finesse up to 181,000 $\pm$ 1,000. These promising parameters will enable experiments in the quantum regime with macroscopic mechanical resonators.
△ Less
Submitted 6 January, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.
-
Measurement of the Casimir force with a ferrule-top sensor
Authors:
P. Zuurbier,
S. de Man,
G. Gruca,
K. Heeck,
D. Iannuzzi
Abstract:
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold coated sphere and a gold coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any…
▽ More
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold coated sphere and a gold coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require any optical triangulation readout) and to the absence of electronics on the sensing head, the instrument represents a significant step ahead for future studies of the Casimir effect under engineered conditions, where the intervening medium or the environmental conditions might be unsuitable for the use of more standard setups.
△ Less
Submitted 15 February, 2011;
originally announced February 2011.
-
Halving the Casimir force with conductive oxides: experimental details
Authors:
Sven de Man,
Kier Heeck,
Davide Iannuzzi
Abstract:
This work is an extended version of a paper published last year in Physical Review Letters [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold coated sphere and a plate coated with either gold or an indium-tin-oxide (ITO) layer. The experiment, which was performed in air, showed that ITO is sufficiently conducting to prevent…
▽ More
This work is an extended version of a paper published last year in Physical Review Letters [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold coated sphere and a plate coated with either gold or an indium-tin-oxide (ITO) layer. The experiment, which was performed in air, showed that ITO is sufficiently conducting to prevent charge accumulation, but still transparent enough to halve the Casimir attraction when compared to gold. Here, we report all the experimental details that, due to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a new technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.
△ Less
Submitted 17 December, 2010;
originally announced December 2010.
-
Halving the Casimir force with conductive oxides
Authors:
S. de Man,
K. Heeck,
R. J. Wijngaarden,
D. Iannuzzi
Abstract:
The possibility to modify the strength of the Casimir effect by tailoring the dielectric functions of the interacting surfaces is regarded as a unique opportunity in the development of Micro- and NanoElectroMechanical Systems. In air, however, one expects that, unless noble metals are used, the electrostatic force arising from trapped charges overcomes the Casimir attraction, leaving no room for…
▽ More
The possibility to modify the strength of the Casimir effect by tailoring the dielectric functions of the interacting surfaces is regarded as a unique opportunity in the development of Micro- and NanoElectroMechanical Systems. In air, however, one expects that, unless noble metals are used, the electrostatic force arising from trapped charges overcomes the Casimir attraction, leaving no room for exploitation of Casimir force engineering at ambient conditions. Here we show that, in the presence of a conductive oxide, the Casimir force can be the dominant interaction even in air, and that the use of conductive oxides allows one to reduce the Casimir force up to a factor of 2 when compared to noble metals.
△ Less
Submitted 17 June, 2009; v1 submitted 23 January, 2009;
originally announced January 2009.
-
No anomalous scaling in electrostatic calibrations for Casimir force measurements
Authors:
S. de Man,
K. Heeck,
D. Iannuzzi
Abstract:
In a recent paper (Phys.Rev.A78, 020101(R) (2008)), Kim at al. have reported a large anomaly in the scaling law of the electrostatic interaction between a sphere and a plate, which was observed during the calibration of their Casimir force set-up. Here we experimentally demonstrate that in proper electrostatic calibrations the scaling law follows the behavior expected from elementary electrostat…
▽ More
In a recent paper (Phys.Rev.A78, 020101(R) (2008)), Kim at al. have reported a large anomaly in the scaling law of the electrostatic interaction between a sphere and a plate, which was observed during the calibration of their Casimir force set-up. Here we experimentally demonstrate that in proper electrostatic calibrations the scaling law follows the behavior expected from elementary electrostatic arguments, even when the electrostatic voltage that one must apply to minimize the force (typically ascribed to contact potentials) depends on the separation between the surfaces.
△ Less
Submitted 6 February, 2009; v1 submitted 23 September, 2008;
originally announced September 2008.