-
An atom interferometer driven by a picosecond frequency comb
Authors:
Cyrille Solaro,
Clément Debavelaere,
Pierre Cladé,
Saïda Guellati-Khelifa
Abstract:
We demonstrate a light-pulse atom interferometer based on the diffraction of free-falling atoms by a picosecond frequency-comb laser. More specifically, we coherently split and recombine wave packets of cold $^{87}$Rb atoms by driving stimulated Raman transitions between the $|5s~^2S_{1/2},F=1\rangle$ and $|5s~^2S_{1/2},F=2\rangle$ hyperfine states, using two trains of picosecond pulses in a count…
▽ More
We demonstrate a light-pulse atom interferometer based on the diffraction of free-falling atoms by a picosecond frequency-comb laser. More specifically, we coherently split and recombine wave packets of cold $^{87}$Rb atoms by driving stimulated Raman transitions between the $|5s~^2S_{1/2},F=1\rangle$ and $|5s~^2S_{1/2},F=2\rangle$ hyperfine states, using two trains of picosecond pulses in a counter-propagating geometry. We study the impact of the pulses length as well as of the interrogation time onto the contrast of the atom interferometer. Our experimental data are well reproduced by a numerical simulation based on an effective coupling which depends on the overlap between the pulses and the atomic cloud. These results pave the way for extending light-pulse interferometry to transitions in other spectral regions and therefore to other species, for new possibilities in metrology, sensing of gravito-inertial effects and tests of fundamental physics.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
Quantum interference measurement of the free fall of anti-hydrogen
Authors:
Olivier Rousselle,
Pierre Cladé,
Saïda Guellati-Khélifa,
Romain Guérout,
Serge Reynaud
Abstract:
We analyze a quantum measurement designed to improve the accuracy for the free-fall acceleration of anti-hydrogen in the GBAR experiment. Including the effect of photo-detachment recoil in the analysis and developing a full quantum analysis of anti-matter wave propagation, we show that the accuracy is improved by approximately three orders of magnitude with respect to the classical timing techniqu…
▽ More
We analyze a quantum measurement designed to improve the accuracy for the free-fall acceleration of anti-hydrogen in the GBAR experiment. Including the effect of photo-detachment recoil in the analysis and developing a full quantum analysis of anti-matter wave propagation, we show that the accuracy is improved by approximately three orders of magnitude with respect to the classical timing technique planned for the current experiment.
△ Less
Submitted 22 April, 2022;
originally announced April 2022.
-
In-line extraction of an ultra-stable frequency signal over an optical fiber link
Authors:
Anthony Bercy,
Saïda Guellati-Khélifa,
Fabio Stefani,
Giorgio Santarelli,
Christian Chardonnet,
Paul-Eric Pottie,
Olivier Lopez,
Anne Amy-Klein
Abstract:
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensatio…
▽ More
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensation. We obtain relative frequency instabilities, expressed as overlapping Allan deviation, of 8x10-16 at 1 s averaging time and a few 10-19 at 1 day. These results are at the state-of-the-art for a link using urban telecommunication fibers. We also propose an improved scheme which delivers an ultra-stable signal of higher power, in order to feed a secondary link. In-line extraction opens the way to a broad distribution of an ultra-stable frequency reference, enabling a wide range of applications beyond metrology.
△ Less
Submitted 6 February, 2014;
originally announced February 2014.
-
State of the art in the determination of the fine structure constant: test of Quantum Electrodynamics and determination of h/mu
Authors:
Rym Bouchendira,
Pierre Cladé,
Saïda Guellati-Khélifa,
François Nez,
François Biraben
Abstract:
The fine structure constant $α$ has a particular status in physics. Its precise determination is required to test the quantum electrodynamics (QED) theory. The constant $α$ is also a keystone for the determination of other fundamental physical constants, especially the ones involved in the framework of the future International System of units. This paper presents Paris experiment, where the fine s…
▽ More
The fine structure constant $α$ has a particular status in physics. Its precise determination is required to test the quantum electrodynamics (QED) theory. The constant $α$ is also a keystone for the determination of other fundamental physical constants, especially the ones involved in the framework of the future International System of units. This paper presents Paris experiment, where the fine structure constant is determined by measuring the recoil velocity of a rubidium atom when it absorbs a photon. The impact of the recent improvement of QED calculations of the electron moment anomaly and the recent measurement of the cesium atom recoil at Berkeley will be discussed. The opportunity to provide a precise value of the ratio $h/m_{\mathrm{u}}$ between the Planck constant and the atomic mass constant will be investigated.
△ Less
Submitted 13 September, 2013;
originally announced September 2013.
-
Compact atomic gravimeter based on a pulsed and accelerated optical lattice
Authors:
Manuel Andia,
Raphael Jannin,
François Nez,
François Biraben,
Saïda Guellati-Khélifa,
Pierre Cladé
Abstract:
We present a new scheme of compact atomic gravimeter based on atom interferometry. Atoms are maintained against gravity using a sequence of coherent accelerations performed by the Bloch oscillations technique. We demonstrate a sensitivity of 4.8$\times 10^{-8}$ with an integration time of 4 min. Combining this method with an atomic elevator allows to measure the local gravity at different position…
▽ More
We present a new scheme of compact atomic gravimeter based on atom interferometry. Atoms are maintained against gravity using a sequence of coherent accelerations performed by the Bloch oscillations technique. We demonstrate a sensitivity of 4.8$\times 10^{-8}$ with an integration time of 4 min. Combining this method with an atomic elevator allows to measure the local gravity at different positions in the vacuum chamber. This method can be of relevance to improve the measurement of the Newtonian gravitational constant $G$.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.