Benchmarking of Fluorescence Lifetime Measurements using Time-Frequency Correlated Photons
Authors:
Tobias Bernd Gäbler,
Nitish Jain,
Patrick Then,
Christian Eggeling,
Markus Gräfe,
Valerio Flavio Gili
Abstract:
The investigation of fluorescence lifetime became an important tool in biology and medical science. So far, established methods of fluorescence lifetime measurements require the illumination of the investigated probes with pulsed or amplitude-modulated light. In this paper, we examine the limitations of an innovative method of fluorescence lifetime using the strong time-frequency correlation of en…
▽ More
The investigation of fluorescence lifetime became an important tool in biology and medical science. So far, established methods of fluorescence lifetime measurements require the illumination of the investigated probes with pulsed or amplitude-modulated light. In this paper, we examine the limitations of an innovative method of fluorescence lifetime using the strong time-frequency correlation of entangled photons generated by a continuous-wave source. For this purpose, we investigate the lifetime of IR-140 to demonstrate the functional principle and its dependencies on different experimental parameters. We also compare this technique with state-of-the-art FLIM and observed an improved figure-of-merit. Finally, we discuss the potential of a quantum advantage.
△ Less
Submitted 26 February, 2025; v1 submitted 15 January, 2025;
originally announced January 2025.
Enhancing entangled two-photon absorption of Nile Red via temperature-controlled SPDC
Authors:
Aleksa Krstić,
Tobias Bernd Gäbler,
Nitish Jain,
Patrick Then,
Valerio Flavio Gili,
Sina Saravi,
Frank Setzpfandt,
Christian Eggeling,
Markus Gräfe
Abstract:
Entangled two-photon absorption can enable a linear scaling of fluorescence emission with the excitation power. In comparison to classical two-photon absorption with a quadratic scaling, this can allow fluorescence imaging or photolithography with high axial resolution at minimal exposure intensities. However, most experimental studies on two-photon absorption were not able to show an unambiguous…
▽ More
Entangled two-photon absorption can enable a linear scaling of fluorescence emission with the excitation power. In comparison to classical two-photon absorption with a quadratic scaling, this can allow fluorescence imaging or photolithography with high axial resolution at minimal exposure intensities. However, most experimental studies on two-photon absorption were not able to show an unambiguous proof of fluorescence emission driven by entangled photon pairs. On the other hand, existing theoretical models struggle to accurately predict the entangled two-photon absorption behavior of chemically complex dyes. In this paper, we introduce an approach to simulate entangled two-photon absorption in common fluorescence dyes considering their chemical properties. Our theoretical model allows a deeper understanding of experimental results and thus the occurrence of entangled two-photon absorption. In particular, we found a remarkable dependency of the absorption probability on the phase-matching temperature of the nonlinear material. Further, we compared results of our theoretical approach to experimental data for Nile Red.
△ Less
Submitted 3 January, 2025; v1 submitted 3 June, 2024;
originally announced June 2024.