-
High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals
Authors:
J. Keller,
H. N. Hausser,
I. M. Richter,
T. Nordmann,
N. M. Bhatt,
J. Kiethe,
H. Liu,
E. Benkler,
B. Lipphardt,
S. Dörscher,
K. Stahl,
J. Klose,
C. Lisdat,
M. Filzinger,
N. Huntemann,
E. Peik,
T. E. Mehlstäubler
Abstract:
Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}^{172}$Yb${}^+$ ions. In first clock comparisons, we see agreement below $1\times10^{-17}$ wit…
▽ More
Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}^{172}$Yb${}^+$ ions. In first clock comparisons, we see agreement below $1\times10^{-17}$ with results obtained using a single In${}^+$ ion, for which we have evaluated the systematic uncertainty to be $2.5\times10^{-18}$. Operation with four clock ions reduces the instability from $1.6\times10^{-15}/\sqrt{t/(1\;\mathrm{s})}$ to $9.2\times10^{-16}/\sqrt{t/(1\;\mathrm{s})}$. We derive a model for decay-related dead time during state preparation, which matches the observed scaling of instability with clock ion number $N$, and indicates that $1/\sqrt{N}$ scaling can be achieved with the addition of a repump laser.
△ Less
Submitted 16 January, 2025;
originally announced January 2025.
-
$^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty
Authors:
H. N. Hausser,
J. Keller,
T. Nordmann,
N. M. Bhatt,
J. Kiethe,
H. Liu,
I. M. Richter,
M. von Boehn,
J. Rahm,
S. Weyers,
E. Benkler,
B. Lipphardt,
S. Doerscher,
K. Stahl,
J. Klose,
C. Lisdat,
M. Filzinger,
N. Huntemann,
E. Peik,
T. E. Mehlstäubler
Abstract:
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3…
▽ More
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;\mathrm{s}}$. We report on absolute frequency measurements with an uncertainty of $1.3\times10^{-16}$ and optical frequency comparisons with clocks based on $^{171}$Yb$^+$ (E3) and $^{87}$Sr. With a fractional uncertainty of $4.4\times10^{-18}$, the former is - to our knowledge - the most accurate frequency ratio value reported to date. For the $^{115}$In$^+$/$^{87}$Sr ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;\mathrm{s}}$.
△ Less
Submitted 16 January, 2025; v1 submitted 26 February, 2024;
originally announced February 2024.
-
Long-distance chronometric leveling with a portable optical clock
Authors:
J. Grotti,
I. Nosske,
S. B. Koller,
S. Herbers,
H. Denker,
L. Timmen,
G. Vishnyakova,
G. Grosche,
T. Waterholter,
A. Kuhl,
S. Koke,
E. Benkler,
M. Giunta,
L. Maisenbacher,
A. Matveev,
S. Dörscher,
R. Schwarz,
A. Al-Masoudi,
T. W. Hänsch,
Th. Udem,
R. Holzwarth,
C. Lisdat
Abstract:
We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured…
▽ More
We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.6)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $27~\mathrm{cm}$ in height.
△ Less
Submitted 29 November, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.
-
A high-performance optical lattice clock based on bosonic atoms
Authors:
Stefano Origlia,
Mysore Srinivas Pramod,
Stephan Schiller,
Yeshpal Singh,
Kai Bongs,
Roman Schwarz,
Ali Al-Masoudi,
Sören Dörscher,
Sofia Herbers,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat
Abstract:
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long inter…
▽ More
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for high-accuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the $^{88}\textrm{Sr} - ^{87}$Sr isotope shift with 12 mHz uncertainty.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
A transportable optical lattice clock with $7\times10^{-17}$ uncertainty
Authors:
S. B. Koller,
J. Grotti,
St. Vogt,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
U. Sterr,
Ch. Lisdat
Abstract:
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of…
▽ More
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of $1 \times 10^{-17}$. The instability of our TOC is $1.3 \times 10^{-15}/\sqrt{(τ/s)}$. Both, the systematic uncertainty and the instability are to our best knowledge currently the best achieved with any type of transportable clock. For autonomous operation the TOC is installed in an air-conditioned car-trailer. It is suitable for chronometric leveling with sub-meter resolution as well as intercontinental cross-linking of optical clocks, which is essential for a redefiniton of the SI second. In addition, the TOC will be used for high precision experiments for fundamental science that are commonly tied to precise frequency measurements and it is a first step to space borne optical clocks
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
Creation of Quantum-Degenerate Gases of Ytterbium in a Compact 2D-/3D-MOT Setup
Authors:
Sören Dörscher,
Alexander Thobe,
Bastian Hundt,
André Kochanke,
Rodolphe Le Targat,
Patrick Windpassinger,
Christoph Becker,
Klaus Sengstock
Abstract:
We report on the first experimental setup based on a 2D-/3D-MOT scheme to create both Bose-Einstein condensates and degenerate Fermi gases of several ytterbium isotopes. Our setup does not require a Zeeman slower and offers the flexibility to simultaneously produce ultracold samples of other atomic species. Furthermore, the extraordinary optical access favors future experiments in optical lattices…
▽ More
We report on the first experimental setup based on a 2D-/3D-MOT scheme to create both Bose-Einstein condensates and degenerate Fermi gases of several ytterbium isotopes. Our setup does not require a Zeeman slower and offers the flexibility to simultaneously produce ultracold samples of other atomic species. Furthermore, the extraordinary optical access favors future experiments in optical lattices. A 2D-MOT on the strong 1S0-1P1 transition captures ytterbium directly from a dispenser of atoms and loads a 3D-MOT on the narrow 1S0-3P1 intercombination transition. Subsequently, atoms are transferred to a crossed optical dipole trap and cooled evaporatively to quantum degeneracy.
△ Less
Submitted 5 March, 2013;
originally announced March 2013.
-
Ultracold quantum gases in triangular optical lattices
Authors:
C. Becker,
P. Soltan-Panahi,
J. Kronjäger,
S. Dörscher,
K. Bongs,
K. Sengstock
Abstract:
Over the last years the exciting developments in the field of ultracold atoms confined in optical lattices have led to numerous theoretical proposals devoted to the quantum simulation of problems e.g. known from condensed matter physics. Many of those ideas demand for experimental environments with non-cubic lattice geometries. In this paper we report on the implementation of a versatile three-b…
▽ More
Over the last years the exciting developments in the field of ultracold atoms confined in optical lattices have led to numerous theoretical proposals devoted to the quantum simulation of problems e.g. known from condensed matter physics. Many of those ideas demand for experimental environments with non-cubic lattice geometries. In this paper we report on the implementation of a versatile three-beam lattice allowing for the generation of triangular as well as hexagonal optical lattices. As an important step the superfluid-Mott insulator (SF-MI) quantum phase transition has been observed and investigated in detail in this lattice geometry for the first time. In addition to this we study the physics of spinor Bose-Einstein condensates (BEC) in the presence of the triangular optical lattice potential, especially spin changing dynamics across the SF-MI transition. Our results suggest that below the SF-MI phase transition, a well-established mean-field model describes the observed data when renormalizing the spin-dependent interaction. Interestingly this opens new perspectives for a lattice driven tuning of a spin dynamics resonance occurring through the interplay of quadratic Zeeman effect and spin-dependent interaction. We finally discuss further lattice configurations which can be realized with our setup.
△ Less
Submitted 18 December, 2009;
originally announced December 2009.