Sensing of magnetic field effects in radical-pair reactions using a quantum sensor
Authors:
Deepak Khurana,
Rasmus H. Jensen,
Rakshyakar Giri,
Juanita Bocquel,
Ulrik L. Andersen,
Kirstine Berg-Sørensen,
Alexander Huck
Abstract:
Magnetic field effects (MFE) in certain chemical reactions have been well established in the last five decades and are attributed to the evolution of transient radical-pairs whose spin dynamics are determined by local and external magnetic fields. The majority of existing experimental techniques used to probe these reactions only provide ensemble averaged reaction parameters and spin chemistry, hi…
▽ More
Magnetic field effects (MFE) in certain chemical reactions have been well established in the last five decades and are attributed to the evolution of transient radical-pairs whose spin dynamics are determined by local and external magnetic fields. The majority of existing experimental techniques used to probe these reactions only provide ensemble averaged reaction parameters and spin chemistry, hindering the observation of the potential presence of quantum coherent phenomena at the single molecule scale. Here, considering a single nitrogen vacancy (NV) centre as quantum sensor, we investigate the prospects and requirements for detection of MFEs on the spin dynamics of radical-pairs at the scale of single and small ensemble of molecules. We employ elaborate and realistic models of radical-pairs, considering its coupling to the local spin environment and the sensor. For two model systems, we derive signals of MFE detectable even in the weak coupling regime between radical-pair and NV quantum sensor, and observe that the dynamics of certain populations, as well as coherence elements, of the density matrix of the radical pair are directly detectable. Our investigations will provide important guidelines for potential detection of spin chemistry of bio-molecules at the single molecule scale, required to witness the hypothesised importance of quantum coherence in biological processes.
△ Less
Submitted 28 September, 2022;
originally announced September 2022.
-
Charge stability and charge-state-based spin readout of shallow nitrogen-vacancy centers in diamond
Authors:
Rakshyakar Giri,
Rasmus H. Jensen,
Deepak Khurana,
Juanita Bocquel,
Ilya P. Radko,
Johannes Lang,
Christian Osterkamp,
Fedor Jelezko,
Kirstine Berg-Sorensen,
Ulrik L. Andersen,
Alexander Huck
Abstract:
Spin-based applications of the negatively charged nitrogen-vacancy (NV) center in diamonds require efficient spin readout. One approach is the spin-to-charge conversion (SCC), relying on mapping the spin states onto the neutral (NV$^0$) and negative (NV$^-$) charge states followed by a subsequent charge readout. With high charge-state stability, SCC enables extended measurement times, increasing p…
▽ More
Spin-based applications of the negatively charged nitrogen-vacancy (NV) center in diamonds require efficient spin readout. One approach is the spin-to-charge conversion (SCC), relying on mapping the spin states onto the neutral (NV$^0$) and negative (NV$^-$) charge states followed by a subsequent charge readout. With high charge-state stability, SCC enables extended measurement times, increasing precision and minimizing noise in the readout compared to the commonly used fluorescence detection. Nano-scale sensing applications, however, require shallow NV centers within a few $\si{\nano \meter}$ distance from the surface where surface related effects might degrade the NV charge state. In this article, we investigate the charge state initialization and stability of single NV centers implanted $\approx \SI{5}{\nano \meter}$ below the surface of a flat diamond plate. We demonstrate the SCC protocol on four shallow NV centers suitable for nano-scale sensing, obtaining a reduced readout noise of 5--6 times the spin-projection noise limit. We investigate the general applicability of SCC for shallow NV centers and observe a correlation between NV charge-state stability and readout noise. Coating the diamond with glycerol improves both charge initialization and stability. Our results reveal the influence of the surface-related charge environment on the NV charge properties and motivate further investigations to functionalize the diamond surface with glycerol or other materials for charge-state stabilization and efficient spin-state readout of shallow NV centers suitable for nano-scale sensing.
△ Less
Submitted 10 November, 2023; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
Authors:
Nikolaj Winther Hansen,
James Luke Webb,
Luca Troise,
Christoffer Olsson,
Leo Tomasevic,
Ovidiu Brinza,
Jocelyn Achard,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Hartwig Roman Siebner,
Kirstine Berg-Sørensen,
Jean-François Perrier,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techni…
▽ More
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
△ Less
Submitted 30 August, 2022;
originally announced August 2022.
-
Laser stimulation of muscle activity with simultaneous detection using a diamond colour centre biosensor
Authors:
Luca Troise,
Nikolaj Winther Hansen,
Christoffer Olsson,
James Luke Webb,
Leo Tomasevic,
Jocelyn Achard,
Ovidiu Brinza,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Hartwig Roman Siebner,
Kirstine Berg-Sørensen,
Jean-François Perrier,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
The detection of physiological activity at the microscopic level is key for understanding the function of biosystems and relating this to physical structure. Current sensing methods often rely on invasive probes to stimulate and detect activity, bearing the risk of inducing damage in the target system. In recent years, a new type of biosensor based on color centers in diamond offers the possibilit…
▽ More
The detection of physiological activity at the microscopic level is key for understanding the function of biosystems and relating this to physical structure. Current sensing methods often rely on invasive probes to stimulate and detect activity, bearing the risk of inducing damage in the target system. In recent years, a new type of biosensor based on color centers in diamond offers the possibility to passively, noninvasively sense and image living biological systems. Here, we use such a sensor for the \textit{in-vitro} recording of the local magnetic field generated by tightly focused, high intensity pulsed laser optogenetic neuromuscular stimulation of the extensor digitorum longus muscles. Recordings captured a compound action potential response and a slow signal component which we seek to explain using a detailed model of the biological system. We show that our sensor is capable of recording localized neuromuscular activity from the laser stimulation site without photovoltaic or fluorescence artifacts associated with alternative techniques. Our work represents an important step towards selective induction of localized neurobiological activity while performing passive sensing and imaging with diamond sensors, motivating further research into mapping of neural activity and intra-cellular processes.
△ Less
Submitted 17 December, 2021;
originally announced December 2021.
-
Investigation and comparison of measurement schemes in the low frequency biosensing regime using solid-state defect centers
Authors:
Andreas F. L. Poulsen,
James L. Webb,
Kirstine Berg-Sørensen,
Ulrik Lund Andersen,
Alexander Huck
Abstract:
Ensembles of solid state defects in diamond make promising quantum sensors with high sensitivity and spatiotemporal resolution. The inhomogeneous broadening and drive amplitude variations across such ensembles have differing impacts on the sensitivity depending on the sensing scheme used, adding to the challenge of choosing the optimal sensing scheme for a particular sensing regime. In this work,…
▽ More
Ensembles of solid state defects in diamond make promising quantum sensors with high sensitivity and spatiotemporal resolution. The inhomogeneous broadening and drive amplitude variations across such ensembles have differing impacts on the sensitivity depending on the sensing scheme used, adding to the challenge of choosing the optimal sensing scheme for a particular sensing regime. In this work, we numerically investigate and compare the predicted sensitivity of schemes based on continuous-wave (CW) optically detected magnetic resonance (ODMR) spectroscopy, pi-pulse ODMR and Ramsey interferometry for sensing using nitrogen-vacancy centers in the low-frequency (<10 kHz) range typical for signals from biological sources. We show that inhomogeneous broadening has the strongest impact on the sensitivity of Ramsey interferometry, and drive amplitude variations least impact the sensitivity of CW ODMR, with all methods constrained by the Rabi frequency. Based on our results, we can identify three different regions of interest. For inhomogeneous broadening less than 0.3 MHz, typical of diamonds used in state of the art sensing experiments, Ramsey interferometry yields the highest sensitivity. In the regime where inhomogeneous broadening is greater than 0.3 MHz, such as for standard optical grade diamonds or in miniaturized integrated devices, drive amplitude variations determine the optimal protocol to use. For low to medium drive amplitude variations, the highest sensitivity is reached using pi-pulse ODMR. For high drive amplitude variations, relevant for widefield microscopic imaging, CW ODMR can yield the best sensing performance.
△ Less
Submitted 27 September, 2021;
originally announced September 2021.
-
High speed microcircuit and synthetic biosignal widefield imaging using nitrogen vacancies in diamond
Authors:
James L. Webb,
Luca Troise,
Nikolaj W. Hansen,
Louise F. Frellsen,
Christian Osterkamp,
Fedor Jelezko,
Steffen Jankuhn,
Jan Meijer,
Kirstine Berg-Sørensen,
Jean-François Perrier,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. Being able to image such signals passively and remotely at the same time is of high importance, to measure without invasive disruption of the system under study or the signal itself. A new approach to…
▽ More
The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. Being able to image such signals passively and remotely at the same time is of high importance, to measure without invasive disruption of the system under study or the signal itself. A new approach to achieve this utilises point defects in solid state materials, in particular nitrogen vacancy (NV) centres in diamond. Acting as a high density array of independent sensors, addressable opto-electronically and highly sensitive to factors including temperature and magnetic field, these are ideally suited to microscopic widefield imaging. In this work we demonstrate such imaging of signals from a microscopic lithographically patterned circuit at the micrometer scale. Using a new type of lock-in amplifier camera, we demonstrate sub-millisecond (up to 3500 frames-per-second) spatially resolved recovery of AC and pulsed electrical current signals, without aliasing or undersampling. Finally, we demonstrate as a proof of principle the recovery of synthetic signals replicating the exact form of signals in a biological neural network: the hippocampus of a mouse.
△ Less
Submitted 29 July, 2021;
originally announced July 2021.
-
Optimal control of a nitrogen-vacancy spin ensemble in diamond for sensing in the pulsed domain
Authors:
Andreas F. L. Poulsen,
Joshua D. Clement,
James L. Webb,
Rasmus H. Jensen,
Kirstine Berg-Sørensen,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
Defects in solid state materials provide an ideal, robust platform for quantum sensing. To deliver maximum sensitivity, a large ensemble of non-interacting defects hosting coherent quantum states are required. Control of such an ensemble is challenging due to the spatial variation in both the defect energy levels and in any control field across a macroscopic sample. In this work we experimentally…
▽ More
Defects in solid state materials provide an ideal, robust platform for quantum sensing. To deliver maximum sensitivity, a large ensemble of non-interacting defects hosting coherent quantum states are required. Control of such an ensemble is challenging due to the spatial variation in both the defect energy levels and in any control field across a macroscopic sample. In this work we experimentally demonstrate that we can overcome these challenges using Floquet theory and optimal control optimization methods to efficiently and coherently control a large defect ensemble, suitable for sensing. We apply our methods experimentally to a spin ensemble of up to 4 $\times$ 10$^9$ nitrogen vacancy (NV) centers in diamond. By considering the physics of the system and explicitly including the hyperfine interaction in the optimization, we design shaped microwave control pulses that can outperform conventional ($π$-) pulses when applied to sensing of temperature or magnetic field, with a potential sensitivity improvement between 11 and 78\%. Through dynamical modelling of the behaviour of the ensemble, we shed light on the physical behaviour of the ensemble system and propose new routes for further improvement.
△ Less
Submitted 25 January, 2021;
originally announced January 2021.
-
Laser threshold magnetometry using green light absorption by diamond nitrogen vacancies in an external cavity laser
Authors:
James L. Webb,
Andreas F. L. Poulsen,
Robert Staacke,
Jan Meijer,
Kirstine Berg-Sørensen,
Ulrik Lund Andersen,
Alexander Huck
Abstract:
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing, promising increased sensitivity for applications ranging from geophysics to biomedicine. Conventional sensing schemes involve monitoring the change in red fluorescence from the NV center under green laser and microwave illumination. Due to the strong fluorescence background from emissio…
▽ More
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing, promising increased sensitivity for applications ranging from geophysics to biomedicine. Conventional sensing schemes involve monitoring the change in red fluorescence from the NV center under green laser and microwave illumination. Due to the strong fluorescence background from emission in the NV triplet state and low relative contrast of any change in output, sensitivity is severely restricted by a high optical shot noise level. Here, we propose a means to avoid this issue, by using the change in green pump absorption through the diamond as part of a semiconductor external cavity laser run close to lasing threshold. We show theoretical sensitivity to magnetic field on the pT/sqrt(Hz) level is possible using a diamond with an optimal density of NV centers. We discuss the physical requirements and limitations of the method, particularly the role of amplified spontaneous emission near threshold and explore realistic implementations using current technology.
△ Less
Submitted 22 January, 2021;
originally announced January 2021.
-
Detection of biological signals from a live mammalian muscle using a diamond quantum sensor
Authors:
James Luke Webb,
Luca Troise,
Nikolaj Winther Hansen,
Christoffer Olsson,
Adam Wojciechowski,
Jocelyn Achard,
Ovidiu Brinza,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Jean-Francois Perrier,
Kirstine Berg-Sorensen,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconductin…
▽ More
The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.
△ Less
Submitted 3 August, 2020;
originally announced August 2020.
-
Quantum-Enhanced continuous-wave stimulated Raman spectroscopy
Authors:
R. B. Andrade,
H. Kerdoncuff,
K. Berg-Sørensen,
T. Gehring,
M. Lassen,
U. L. Andersen
Abstract:
Stimulated Raman spectroscopy has become a powerful tool to study the spatiodynamics of molecular bonds with high sensitivity, resolution and speed. However, sensitivity and speed of state-of-the-art stimulated Raman spectroscopy are currently limited by the shot-noise of the light beam probing the Raman process. Here, we demonstrate an enhancement of the sensitivity of continuous-wave stimulated…
▽ More
Stimulated Raman spectroscopy has become a powerful tool to study the spatiodynamics of molecular bonds with high sensitivity, resolution and speed. However, sensitivity and speed of state-of-the-art stimulated Raman spectroscopy are currently limited by the shot-noise of the light beam probing the Raman process. Here, we demonstrate an enhancement of the sensitivity of continuous-wave stimulated Raman spectroscopy by reducing the quantum noise of the probing light below the shot-noise limit by means of amplitude squeezed states of light. Probing polymer samples with Raman shifts around 2950 $cm^{-1}$ with squeezed states, we demonstrate a quantum-enhancement of the stimulated Raman signal-to-noise ratio (SNR) of 3.60 dB relative to the shot-noise limited SNR. Our proof-of-concept demonstration of quantum-enhanced Raman spectroscopy paves the way for a new generation of Raman microscopes, where weak Raman transitions can be imaged without the use of markers or an increase in the total optical power.
△ Less
Submitted 11 February, 2020;
originally announced February 2020.