-
Advanced LIGO detector performance in the fourth observing run
Authors:
E. Capote,
W. Jia,
N. Aritomi,
M. Nakano,
V. Xu,
R. Abbott,
I. Abouelfettouh,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
S. K. Apple,
K. Arai,
S. M. Aston,
M. Ball,
S. W. Ballmer,
D. Barker,
L. Barsotti,
B. K. Berger,
J. Betzwieser,
D. Bhattacharjee,
G. Billingsley,
S. Biscans,
C. D. Blair,
N. Bode,
E. Bonilla
, et al. (171 additional authors not shown)
Abstract:
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron st…
▽ More
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.
△ Less
Submitted 21 November, 2024;
originally announced November 2024.
-
Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 16 October, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing
Authors:
Yuhang Zhao,
Eleonora Capocasa,
Marc Eisenmann,
Naoki Aritomi,
Michael Page,
Yuefan Guo,
Eleonora Polini,
Koji Arai,
Yoichi Aso,
Martin van Beuzekom,
Yao-Chin Huang,
Ray-Kuang Lee,
Harald Lück,
Osamu Miyakawa,
Pierre Prat,
Ayaka Shoda,
Matteo Tacca,
Ryutaro Takahashi,
Henning Vahlbruch,
Marco Vardaro,
Chien-Ming Wu,
Matteo Leonardi,
Matteo Barsuglia,
Raffaele Flaminio
Abstract:
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-p…
▽ More
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.
△ Less
Submitted 21 March, 2022;
originally announced March 2022.