Showing 1–2 of 2 results for author: Sodroski, J
-
On the parameters affecting dual-target-function evaluation of single-particle selection from cryo-electron micrographs
Authors:
Zhou Yu,
Wei Li Wang,
Luis R. Castillo-Menendez,
Joseph Sodroski,
Youdong Mao
Abstract:
In the analysis of frozen hydrated biomolecules by single-particle cryo-electron microscopy, template-based particle picking by a target function called fast local correlation (FLC) allows a large number of particle images to be automatically picked from micrographs. A second, independent target function based on maximum likelihood (ML) can be used to align the images and verify the presence of si…
▽ More
In the analysis of frozen hydrated biomolecules by single-particle cryo-electron microscopy, template-based particle picking by a target function called fast local correlation (FLC) allows a large number of particle images to be automatically picked from micrographs. A second, independent target function based on maximum likelihood (ML) can be used to align the images and verify the presence of signal in the picked particles. Although the paradigm of this dual-target-function (DTF) evaluation of single-particle selection has been practiced in recent years, it remains unclear how the performance of this DTF approach is affected by the signal-to-noise ratio of the images and by the choice of references for FLC and ML. Here we examine this problem through a systematic study of simulated data, followed by experimental substantiation. We quantitatively pinpoint the critical signal-to-noise ratio (SNR), at which the DTF approach starts losing its ability to select and verify particles from cryo-EM micrographs. A Gaussian model is shown to be as effective in picking particles as a single projection view of the imaged molecule in the tested cases. For both simulated micrographs and real cryo-EM data of the 173-kDa glucose isomerase complex, we found that the use of a Gaussian model to initialize the target functions suppressed the detrimental effect of reference bias in template-based particle selection. Given a sufficient signal-to-noise ratio in the images and the appropriate choice of references, the DTF approach can expedite the automated assembly of single-particle data sets.
△ Less
Submitted 23 September, 2015;
originally announced September 2015.
-
Dual-target function validation of single-particle selection from low-contrast cryo-electron micrographs
Authors:
Youdong Mao,
Luis R. Castillo-Menendez,
Joseph Sodroski
Abstract:
Weak-signal detection and single-particle selection from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy (cryo-EM) presents a practical challenge. Cryo-EM image contrast degrades as the size of biomolecules of structural interest decreases. When the image contrast falls into a range where the location or presence of single particles becomes ambiguous, a need ar…
▽ More
Weak-signal detection and single-particle selection from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy (cryo-EM) presents a practical challenge. Cryo-EM image contrast degrades as the size of biomolecules of structural interest decreases. When the image contrast falls into a range where the location or presence of single particles becomes ambiguous, a need arises for objective computational approaches to detect weak signal and to select and verify particles from these low-contrast micrographs. Here we propose an objective validation scheme for low-contrast particle selection using a combination of two different target functions. In an implementation of this dual-target function (DTF) validation, a first target function of fast local correlation was used to select particles through template matching, followed by signal validation through a second target function of maximum likelihood. By a systematic study of simulated data, we found that such an implementation of DTF validation is capable of selecting and verifying particles from cryo-EM micrographs with a signal-to-noise ratio as low as 0.002. Importantly, we demonstrated that DTF validation can robustly evade over-fitting or reference bias from the particle-picking template, allowing true signal to emerge from amidst heavy noise in an objective fashion. The DTF approach allows efficient assembly of a large number of single-particle cryo-EM images of smaller biomolecules or specimens containing contrast-degrading agents like detergents in a semi-automatic manner.
△ Less
Submitted 10 September, 2013;
originally announced September 2013.