-
Moment-based metrics for molecules computable from cryo-EM images
Authors:
Andy Zhang,
Oscar Mickelin,
Joe Kileel,
Eric J. Verbeke,
Nicholas F. Marshall,
Marc Aurèle Gilles,
Amit Singer
Abstract:
Single particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of recovering the high-resolution 3-D structure of biological macromolecules from many noisy and randomly oriented projection images. One notable approach to 3-D reconstruction, known as Kam's method, relies on the moments of the 2-D images. Inspired by Kam's method, we introduce a rotationally invariant metric…
▽ More
Single particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of recovering the high-resolution 3-D structure of biological macromolecules from many noisy and randomly oriented projection images. One notable approach to 3-D reconstruction, known as Kam's method, relies on the moments of the 2-D images. Inspired by Kam's method, we introduce a rotationally invariant metric between two molecular structures, which does not require 3-D alignment. Further, we introduce a metric between a stack of projection images and a molecular structure, which is invariant to rotations and reflections and does not require performing 3-D reconstruction. Additionally, the latter metric does not assume a uniform distribution of viewing angles. We demonstrate uses of the new metrics on synthetic and experimental datasets, highlighting their ability to measure structural similarity.
△ Less
Submitted 26 January, 2024;
originally announced January 2024.
-
Alignment of Density Maps in Wasserstein Distance
Authors:
Amit Singer,
Ruiyi Yang
Abstract:
In this paper we propose an algorithm for aligning three-dimensional objects when represented as density maps, motivated by applications in cryogenic electron microscopy. The algorithm is based on minimizing the 1-Wasserstein distance between the density maps after a rigid transformation. The induced loss function enjoys a more benign landscape than its Euclidean counterpart and Bayesian optimizat…
▽ More
In this paper we propose an algorithm for aligning three-dimensional objects when represented as density maps, motivated by applications in cryogenic electron microscopy. The algorithm is based on minimizing the 1-Wasserstein distance between the density maps after a rigid transformation. The induced loss function enjoys a more benign landscape than its Euclidean counterpart and Bayesian optimization is employed for computation. Numerical experiments show improved accuracy and efficiency over existing algorithms on the alignment of real protein molecules. In the context of aligning heterogeneous pairs, we illustrate a potential need for new distance functions.
△ Less
Submitted 11 March, 2024; v1 submitted 20 May, 2023;
originally announced May 2023.
-
A stochastic approximate expectation-maximization for structure determination directly from cryo-EM micrographs
Authors:
Shay Kreymer,
Amit Singer,
Tamir Bendory
Abstract:
A single-particle cryo-electron microscopy (cryo-EM) measurement, called a micrograph, consists of multiple two-dimensional tomographic projections of a three-dimensional molecular structure at unknown locations, taken under unknown viewing directions. All existing cryo-EM algorithmic pipelines first locate and extract the projection images, and then reconstruct the structure from the extracted im…
▽ More
A single-particle cryo-electron microscopy (cryo-EM) measurement, called a micrograph, consists of multiple two-dimensional tomographic projections of a three-dimensional molecular structure at unknown locations, taken under unknown viewing directions. All existing cryo-EM algorithmic pipelines first locate and extract the projection images, and then reconstruct the structure from the extracted images. However, if the molecular structure is small, the signal-to-noise ratio (SNR) of the data is very low, and thus accurate detection of projection images within the micrograph is challenging. Consequently, all standard techniques fail in low-SNR regimes. To recover molecular structures from measurements of low SNR, and in particular small molecular structures, we devise a stochastic approximate expectation-maximization algorithm to estimate the three-dimensional structure directly from the micrograph, bypassing locating the projection images. We corroborate our computational scheme with numerical experiments, and present successful structure recoveries from simulated noisy measurements.
△ Less
Submitted 24 February, 2023;
originally announced March 2023.
-
Quantitatively visualizing bipartite datasets
Authors:
Tal Einav,
Yuehaw Khoo,
Amit Singer
Abstract:
As experiments continue to increase in size and scope, a fundamental challenge of subsequent analyses is to recast the wealth of information into an intuitive and readily-interpretable form. Often, each measurement only conveys the relationship between a pair of entries, and it is difficult to integrate these local interactions across a dataset to form a cohesive global picture. The classic locali…
▽ More
As experiments continue to increase in size and scope, a fundamental challenge of subsequent analyses is to recast the wealth of information into an intuitive and readily-interpretable form. Often, each measurement only conveys the relationship between a pair of entries, and it is difficult to integrate these local interactions across a dataset to form a cohesive global picture. The classic localization problem tackles this question, transforming local measurements into a global map that reveals the underlying structure of a system. Here, we examine the more challenging bipartite localization problem, where pairwise distances are only available for bipartite data comprising two classes of entries (such as antibody-virus interactions, drug-cell potency, or user-rating profiles). We modify previous algorithms to solve bipartite localization and examine how each method behaves in the presence of noise, outliers, and partially-observed data. As a proof of concept, we apply these algorithms to antibody-virus neutralization measurements to create a basis set of antibody behaviors, formalize how potently inhibiting some viruses necessitates weakly inhibiting other viruses, and quantify how often combinations of antibodies exhibit degenerate behavior.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
A Molecular Prior Distribution for Bayesian Inference Based on Wilson Statistics
Authors:
Marc Aurèle Gilles,
Amit Singer
Abstract:
Background and Objective: Wilson statistics describe well the power spectrum of proteins at high frequencies. Therefore, it has found several applications in structural biology, e.g., it is the basis for sharpening steps used in cryogenic electron microscopy (cryo-EM). A recent paper gave the first rigorous proof of Wilson statistics based on a formalism of Wilson's original argument. This new ana…
▽ More
Background and Objective: Wilson statistics describe well the power spectrum of proteins at high frequencies. Therefore, it has found several applications in structural biology, e.g., it is the basis for sharpening steps used in cryogenic electron microscopy (cryo-EM). A recent paper gave the first rigorous proof of Wilson statistics based on a formalism of Wilson's original argument. This new analysis also leads to statistical estimates of the scattering potential of proteins that reveal a correlation between neighboring Fourier coefficients. Here we exploit these estimates to craft a novel prior that can be used for Bayesian inference of molecular structures. Methods: We describe the properties of the prior and the computation of its hyperparameters. We then evaluate the prior on two synthetic linear inverse problems, and compare against a popular prior in cryo-EM reconstruction at a range of SNRs. Results: We show that the new prior effectively suppresses noise and fills-in low SNR regions in the spectral domain. Furthermore, it improves the resolution of estimates on the problems considered for a wide range of SNR and produces Fourier Shell Correlation curves that are insensitive to masking effects. Conclusions: We analyze the assumptions in the model, discuss relations to other regularization strategies, and postulate on potential implications for structure determination in cryo-EM.
△ Less
Submitted 2 May, 2022; v1 submitted 18 February, 2022;
originally announced February 2022.
-
Magnetoelectric Bio-Implants Powered and Programmed by a Single Transmitter for Coordinated Multisite Stimulation
Authors:
Zhanghao Yu,
Joshua C. Chen,
Yan He,
Fatima T. Alrashdan,
Benjamin W. Avants,
Amanda Singer,
Jacob T. Robinson,
Kaiyuan Yang
Abstract:
This article presents a hardware platform including stimulating implants wirelessly powered and controlled by a shared transmitter (TX) for coordinated leadless multisite stimulation. The adopted novel single-TX, multiple-implant structure can flexibly deploy stimuli, improve system efficiency, easily scale stimulating channel quantity, and relieve efforts in device synchronization. In the propose…
▽ More
This article presents a hardware platform including stimulating implants wirelessly powered and controlled by a shared transmitter (TX) for coordinated leadless multisite stimulation. The adopted novel single-TX, multiple-implant structure can flexibly deploy stimuli, improve system efficiency, easily scale stimulating channel quantity, and relieve efforts in device synchronization. In the proposed system, a wireless link leveraging magnetoelectric (ME) effect is co-designed with a robust and efficient system-on-chip (SoC) to enable reliable operation and individual programming of every implant. Each implant integrates a 0.8-mm2 chip, a 6-mm2 ME film, and an energy storage capacitor within a 6.2-mm3 size. ME power transfer is capable of safely transmitting milliwatt power to devices placed several centimeters away from the TX coil, maintaining good efficiency with size constraints, and tolerating 60 degree, 1.5-cm misalignment in angular and lateral movement. The SoC robustly operates with 2-V source amplitude variations that spans a 40-mm TX-implant distance change, realizes individual addressability through physical unclonable function (PUF) IDs, and achieves 90% efficiency for 1.5-3.5-V stimulation with fully programmable stimulation parameters.
△ Less
Submitted 31 December, 2021;
originally announced December 2021.
-
MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant
Authors:
Zhanghao Yu,
Joshua C. Chen,
Fatima T. Alrashdan,
Benjamin W. Avants,
Yan He,
Amanda Singer,
Jacob T. Robinson,
Kaiyuan Yang
Abstract:
This paper presents the first wireless and programmable neural stimulator leveraging magnetoelectric (ME) effects for power and data transfer. Thanks to low tissue absorption, low misalignment sensitivity and high power transfer efficiency, the ME effect enables safe delivery of high power levels (a few milliwatts) at low resonant frequencies (~250 kHz) to mm-sized implants deep inside the body (3…
▽ More
This paper presents the first wireless and programmable neural stimulator leveraging magnetoelectric (ME) effects for power and data transfer. Thanks to low tissue absorption, low misalignment sensitivity and high power transfer efficiency, the ME effect enables safe delivery of high power levels (a few milliwatts) at low resonant frequencies (~250 kHz) to mm-sized implants deep inside the body (30-mm depth). The presented MagNI (Magnetoelectric Neural Implant) consists of a 1.5-mm$^2$ 180-nm CMOS chip, an in-house built 4x2 mm ME film, an energy storage capacitor, and on-board electrodes on a flexible polyimide substrate with a total volume of 8.2 mm$^3$ . The chip with a power consumption of 23.7 $μ$W includes robust system control and data recovery mechanisms under source amplitude variations (1-V variation tolerance). The system delivers fully-programmable bi-phasic current-controlled stimulation with patterns covering 0.05-to-1.5-mA amplitude, 64-to-512-$μ$s pulse width, and 0-to-200Hz repetition frequency for neurostimulation.
△ Less
Submitted 6 July, 2021;
originally announced July 2021.
-
Earthmover-based manifold learning for analyzing molecular conformation spaces
Authors:
Nathan Zelesko,
Amit Moscovich,
Joe Kileel,
Amit Singer
Abstract:
In this paper, we propose a novel approach for manifold learning that combines the Earthmover's distance (EMD) with the diffusion maps method for dimensionality reduction. We demonstrate the potential benefits of this approach for learning shape spaces of proteins and other flexible macromolecules using a simulated dataset of 3-D density maps that mimic the non-uniform rotary motion of ATP synthas…
▽ More
In this paper, we propose a novel approach for manifold learning that combines the Earthmover's distance (EMD) with the diffusion maps method for dimensionality reduction. We demonstrate the potential benefits of this approach for learning shape spaces of proteins and other flexible macromolecules using a simulated dataset of 3-D density maps that mimic the non-uniform rotary motion of ATP synthase. Our results show that EMD-based diffusion maps require far fewer samples to recover the intrinsic geometry than the standard diffusion maps algorithm that is based on the Euclidean distance. To reduce the computational burden of calculating the EMD for all volume pairs, we employ a wavelet-based approximation to the EMD which reduces the computation of the pairwise EMDs to a computation of pairwise weighted-$\ell_1$ distances between wavelet coefficient vectors.
△ Less
Submitted 15 October, 2019;
originally announced November 2019.
-
Method of moments for 3-D single particle ab initio modeling with non-uniform distribution of viewing angles
Authors:
Nir Sharon,
Joe Kileel,
Yuehaw Khoo,
Boris Landa,
Amit Singer
Abstract:
Single-particle reconstruction in cryo-electron microscopy (cryo-EM) is an increasingly popular technique for determining the 3-D structure of a molecule from several noisy 2-D projections images taken at unknown viewing angles. Most reconstruction algorithms require a low-resolution initialization for the 3-D structure, which is the goal of ab initio modeling. Suggested by Zvi Kam in 1980, the me…
▽ More
Single-particle reconstruction in cryo-electron microscopy (cryo-EM) is an increasingly popular technique for determining the 3-D structure of a molecule from several noisy 2-D projections images taken at unknown viewing angles. Most reconstruction algorithms require a low-resolution initialization for the 3-D structure, which is the goal of ab initio modeling. Suggested by Zvi Kam in 1980, the method of moments (MoM) offers one approach, wherein low-order statistics of the 2-D images are computed and a 3-D structure is estimated by solving a system of polynomial equations. Unfortunately, Kam's method suffers from restrictive assumptions, most notably that viewing angles should be distributed uniformly. Often unrealistic, uniformity entails the computation of higher-order correlations, as in this case first and second moments fail to determine the 3-D structure. In the present paper, we remove this hypothesis, by permitting an unknown, non-uniform distribution of viewing angles in MoM. Perhaps surprisingly, we show that this case is statistically easier than the uniform case, as now first and second moments generically suffice to determine low-resolution expansions of the molecule. In the idealized setting of a known, non-uniform distribution, we find an efficient provable algorithm inverting first and second moments. For unknown, non-uniform distributions, we use non-convex optimization methods to solve for both the molecule and distribution.
△ Less
Submitted 23 November, 2019; v1 submitted 11 July, 2019;
originally announced July 2019.
-
3D ab initio modeling in cryo-EM by autocorrelation analysis
Authors:
Eitan Levin,
Tamir Bendory,
Nicolas Boumal,
Joe Kileel,
Amit Singer
Abstract:
Single-Particle Reconstruction (SPR) in Cryo-Electron Microscopy (cryo-EM) is the task of estimating the 3D structure of a molecule from a set of noisy 2D projections, taken from unknown viewing directions. Many algorithms for SPR start from an initial reference molecule, and alternate between refining the estimated viewing angles given the molecule, and refining the molecule given the viewing ang…
▽ More
Single-Particle Reconstruction (SPR) in Cryo-Electron Microscopy (cryo-EM) is the task of estimating the 3D structure of a molecule from a set of noisy 2D projections, taken from unknown viewing directions. Many algorithms for SPR start from an initial reference molecule, and alternate between refining the estimated viewing angles given the molecule, and refining the molecule given the viewing angles. This scheme is called iterative refinement. Reliance on an initial, user-chosen reference introduces model bias, and poor initialization can lead to slow convergence. Furthermore, since no ground truth is available for an unsolved molecule, it is difficult to validate the obtained results. This creates the need for high quality ab initio models that can be quickly obtained from experimental data with minimal priors, and which can also be used for validation. We propose a procedure to obtain such an ab initio model directly from raw data using Kam's autocorrelation method. Kam's method has been known since 1980, but it leads to an underdetermined system, with missing orthogonal matrices. Until now, this system has been solved only for special cases, such as highly symmetric molecules or molecules for which a homologous structure was already available. In this paper, we show that knowledge of just two clean projections is sufficient to guarantee a unique solution to the system. This system is solved by an optimization-based heuristic. For the first time, we are then able to obtain a low-resolution ab initio model of an asymmetric molecule directly from raw data, without 2D class averaging and without tilting. Numerical results are presented on both synthetic and experimental data.
△ Less
Submitted 7 January, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
Anisotropic twicing for single particle reconstruction using autocorrelation analysis
Authors:
Tejal Bhamre,
Teng Zhang,
Amit Singer
Abstract:
The missing phase problem in X-ray crystallography is commonly solved using the technique of molecular replacement, which borrows phases from a previously solved homologous structure, and appends them to the measured Fourier magnitudes of the diffraction patterns of the unknown structure. More recently, molecular replacement has been proposed for solving the missing orthogonal matrices problem ari…
▽ More
The missing phase problem in X-ray crystallography is commonly solved using the technique of molecular replacement, which borrows phases from a previously solved homologous structure, and appends them to the measured Fourier magnitudes of the diffraction patterns of the unknown structure. More recently, molecular replacement has been proposed for solving the missing orthogonal matrices problem arising in Kam's autocorrelation analysis for single particle reconstruction using X-ray free electron lasers and cryo-EM. In classical molecular replacement, it is common to estimate the magnitudes of the unknown structure as twice the measured magnitudes minus the magnitudes of the homologous structure, a procedure known as `twicing'. Mathematically, this is equivalent to finding an unbiased estimator for a complex-valued scalar. We generalize this scheme for the case of estimating real or complex valued matrices arising in single particle autocorrelation analysis. We name this approach "Anisotropic Twicing" because unlike the scalar case, the unbiased estimator is not obtained by a simple magnitude isotropic correction. We compare the performance of the least squares, twicing and anisotropic twicing estimators on synthetic and experimental datasets. We demonstrate 3D homology modeling in cryo-EM directly from experimental data without iterative refinement or class averaging, for the first time.
△ Less
Submitted 26 April, 2017;
originally announced April 2017.
-
Mahalanobis Distance for Class Averaging of Cryo-EM Images
Authors:
Tejal Bhamre,
Zhizhen Zhao,
Amit Singer
Abstract:
Single particle reconstruction (SPR) from cryo-electron microscopy (EM) is a technique in which the 3D structure of a molecule needs to be determined from its contrast transfer function (CTF) affected, noisy 2D projection images taken at unknown viewing directions. One of the main challenges in cryo-EM is the typically low signal to noise ratio (SNR) of the acquired images. 2D classification of im…
▽ More
Single particle reconstruction (SPR) from cryo-electron microscopy (EM) is a technique in which the 3D structure of a molecule needs to be determined from its contrast transfer function (CTF) affected, noisy 2D projection images taken at unknown viewing directions. One of the main challenges in cryo-EM is the typically low signal to noise ratio (SNR) of the acquired images. 2D classification of images, followed by class averaging, improves the SNR of the resulting averages, and is used for selecting particles from micrographs and for inspecting the particle images. We introduce a new affinity measure, akin to the Mahalanobis distance, to compare cryo-EM images belonging to different defocus groups. The new similarity measure is employed to detect similar images, thereby leading to an improved algorithm for class averaging. We evaluate the performance of the proposed class averaging procedure on synthetic datasets, obtaining state of the art classification.
△ Less
Submitted 24 January, 2017; v1 submitted 10 November, 2016;
originally announced November 2016.
-
Denoising and Covariance Estimation of Single Particle Cryo-EM Images
Authors:
Tejal Bhamre,
Teng Zhang,
Amit Singer
Abstract:
The problem of image restoration in cryo-EM entails correcting for the effects of the Contrast Transfer Function (CTF) and noise. Popular methods for image restoration include `phase flipping', which corrects only for the Fourier phases but not amplitudes, and Wiener filtering, which requires the spectral signal to noise ratio. We propose a new image restoration method which we call `Covariance Wi…
▽ More
The problem of image restoration in cryo-EM entails correcting for the effects of the Contrast Transfer Function (CTF) and noise. Popular methods for image restoration include `phase flipping', which corrects only for the Fourier phases but not amplitudes, and Wiener filtering, which requires the spectral signal to noise ratio. We propose a new image restoration method which we call `Covariance Wiener Filtering' (CWF). In CWF, the covariance matrix of the projection images is used within the classical Wiener filtering framework for solving the image restoration deconvolution problem. Our estimation procedure for the covariance matrix is new and successfully corrects for the CTF. We demonstrate the efficacy of CWF by applying it to restore both simulated and experimental cryo-EM images. Results with experimental datasets demonstrate that CWF provides a good way to evaluate the particle images and to see what the dataset contains even without 2D classification and averaging.
△ Less
Submitted 6 April, 2016; v1 submitted 21 February, 2016;
originally announced February 2016.
-
Rotationally Invariant Image Representation for Viewing Direction Classification in Cryo-EM
Authors:
Zhizhen Zhao,
Amit Singer
Abstract:
We introduce a new rotationally invariant viewing angle classification method for identifying, among a large number of Cryo-EM projection images, similar views without prior knowledge of the molecule. Our rotationally invariant features are based on the bispectrum. Each image is denoised and compressed using steerable principal component analysis (PCA) such that rotating an image is equivalent to…
▽ More
We introduce a new rotationally invariant viewing angle classification method for identifying, among a large number of Cryo-EM projection images, similar views without prior knowledge of the molecule. Our rotationally invariant features are based on the bispectrum. Each image is denoised and compressed using steerable principal component analysis (PCA) such that rotating an image is equivalent to phase shifting the expansion coefficients. Thus we are able to extend the theory of bispectrum of 1D periodic signals to 2D images. The randomized PCA algorithm is then used to efficiently reduce the dimensionality of the bispectrum coefficients, enabling fast computation of the similarity between any pair of images. The nearest neighbors provide an initial classification of similar viewing angles. In this way, rotational alignment is only performed for images with their nearest neighbors. The initial nearest neighbor classification and alignment are further improved by a new classification method called vector diffusion maps. Our pipeline for viewing angle classification and alignment is experimentally shown to be faster and more accurate than reference-free alignment with rotationally invariant K-means clustering, MSA/MRA 2D classification, and their modern approximations.
△ Less
Submitted 17 March, 2014; v1 submitted 29 September, 2013;
originally announced September 2013.
-
A Fourier-based Approach for Iterative 3D Reconstruction from Cryo-EM Images
Authors:
Lanhui Wang,
Yoel Shkolnisky,
Amit Singer
Abstract:
A major challenge in single particle reconstruction methods using cryo-electron microscopy is to attain a resolution sufficient to interpret fine details in three-dimensional (3D) macromolecular structures. Obtaining high resolution 3D reconstructions is difficult due to unknown orientations and positions of the imaged particles, possible incomplete coverage of the viewing directions, high level o…
▽ More
A major challenge in single particle reconstruction methods using cryo-electron microscopy is to attain a resolution sufficient to interpret fine details in three-dimensional (3D) macromolecular structures. Obtaining high resolution 3D reconstructions is difficult due to unknown orientations and positions of the imaged particles, possible incomplete coverage of the viewing directions, high level of noise in the projection images, and limiting effects of the contrast transfer function of the electron microscope. In this paper, we focus on the 3D reconstruction problem from projection images assuming an existing estimate for their orientations and positions. We propose a fast and accurate Fourier-based Iterative Reconstruction Method (FIRM) that exploits the Toeplitz structure of the operator ${\bf A}^{*}{\bf A}$, where $\bf A$ is the forward projector and ${\bf A}^{*}$ is the back projector. The operator ${\bf A}^{*}{\bf A}$ is equivalent to a convolution with a kernel. The kernel is pre-computed using the non-uniform Fast Fourier Transform and is efficiently applied in each iteration step. The iterations by FIRM are therefore considerably faster than those of traditional iterative algebraic approaches, while maintaining the same accuracy even when the viewing directions are unevenly distributed. The time complexity of FIRM is comparable to the direct Fourier inversion method. Moreover, FIRM combines images from different defocus groups simultaneously and can handle a wide range of regularization terms. We provide experimental results on simulated data that demonstrate the speed and accuracy of FIRM in comparison with current methods.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
Orientation Determination from Cryo-EM images Using Least Unsquared Deviation
Authors:
Lanhui Wang,
Amit Singer,
Zaiwen Wen
Abstract:
A major challenge in single particle reconstruction from cryo-electron microscopy is to establish a reliable ab-initio three-dimensional model using two-dimensional projection images with unknown orientations. Common-lines based methods estimate the orientations without additional geometric information. However, such methods fail when the detection rate of common-lines is too low due to the high l…
▽ More
A major challenge in single particle reconstruction from cryo-electron microscopy is to establish a reliable ab-initio three-dimensional model using two-dimensional projection images with unknown orientations. Common-lines based methods estimate the orientations without additional geometric information. However, such methods fail when the detection rate of common-lines is too low due to the high level of noise in the images. An approximation to the least squares global self consistency error was obtained using convex relaxation by semidefinite programming. In this paper we introduce a more robust global self consistency error and show that the corresponding optimization problem can be solved via semidefinite relaxation. In order to prevent artificial clustering of the estimated viewing directions, we further introduce a spectral norm term that is added as a constraint or as a regularization term to the relaxed minimization problem. The resulted problems are solved by using either the alternating direction method of multipliers or an iteratively reweighted least squares procedure. Numerical experiments with both simulated and real images demonstrate that the proposed methods significantly reduce the orientation estimation error when the detection rate of common-lines is low.
△ Less
Submitted 10 April, 2013; v1 submitted 29 November, 2012;
originally announced November 2012.
-
Eigenvector Synchronization, Graph Rigidity and the Molecule Problem
Authors:
Mihai Cucuringu,
Amit Singer,
David Cowburn
Abstract:
The graph realization problem has received a great deal of attention in recent years, due to its importance in applications such as wireless sensor networks and structural biology. In this paper, we extend on previous work and propose the 3D-ASAP algorithm, for the graph realization problem in $\mathbb{R}^3$, given a sparse and noisy set of distance measurements. 3D-ASAP is a divide and conquer, n…
▽ More
The graph realization problem has received a great deal of attention in recent years, due to its importance in applications such as wireless sensor networks and structural biology. In this paper, we extend on previous work and propose the 3D-ASAP algorithm, for the graph realization problem in $\mathbb{R}^3$, given a sparse and noisy set of distance measurements. 3D-ASAP is a divide and conquer, non-incremental and non-iterative algorithm, which integrates local distance information into a global structure determination. Our approach starts with identifying, for every node, a subgraph of its 1-hop neighborhood graph, which can be accurately embedded in its own coordinate system. In the noise-free case, the computed coordinates of the sensors in each patch must agree with their global positioning up to some unknown rigid motion, that is, up to translation, rotation and possibly reflection. In other words, to every patch there corresponds an element of the Euclidean group Euc(3) of rigid transformations in $\mathbb{R}^3$, and the goal is to estimate the group elements that will properly align all the patches in a globally consistent way. Furthermore, 3D-ASAP successfully incorporates information specific to the molecule problem in structural biology, in particular information on known substructures and their orientation. In addition, we also propose 3D-SP-ASAP, a faster version of 3D-ASAP, which uses a spectral partitioning algorithm as a preprocessing step for dividing the initial graph into smaller subgraphs. Our extensive numerical simulations show that 3D-ASAP and 3D-SP-ASAP are very robust to high levels of noise in the measured distances and to sparse connectivity in the measurement graph, and compare favorably to similar state-of-the art localization algorithms.
△ Less
Submitted 1 March, 2012; v1 submitted 9 November, 2011;
originally announced November 2011.