-
Wireless Ear EEG to Monitor Drowsiness
Authors:
Ryan Kaveh,
Carolyn Schwendeman,
Leslie Pu,
Ana C. Arias,
Rikky Muller
Abstract:
Neural wearables can enable life-saving drowsiness and health monitoring for pilots and drivers. While existing in-cabin sensors may provide alerts, wearables can enable monitoring across more environments. Current neural wearables are promising but most require wet-electrodes and bulky electronics. This work showcases in-ear, dry-electrode earpieces used to monitor drowsiness with compact hardwar…
▽ More
Neural wearables can enable life-saving drowsiness and health monitoring for pilots and drivers. While existing in-cabin sensors may provide alerts, wearables can enable monitoring across more environments. Current neural wearables are promising but most require wet-electrodes and bulky electronics. This work showcases in-ear, dry-electrode earpieces used to monitor drowsiness with compact hardware. The employed system integrates additive-manufacturing for dry, user-generic earpieces, existing wireless electronics, and offline classification algorithms. Thirty-five hours of electrophysiological data were recorded across nine subjects performing drowsiness-inducing tasks. Three classifier models were trained with user-specific, leave-one-trial-out, and leave-one-user-out splits. The support-vector-machine classifier achieved an accuracy of 93.2% while evaluating users it has seen before and 93.3% when evaluating a never-before-seen user. These results demonstrate wireless, dry, user-generic earpieces used to classify drowsiness with comparable accuracies to existing state-of-the-art, wet electrode in-ear and scalp systems. Further, this work illustrates the feasibility of population-trained classification in future electrophysiological applications.
△ Less
Submitted 13 May, 2024; v1 submitted 11 January, 2024;
originally announced January 2024.
-
A Wright-Fisher graph model and the impact of directional selection on genetic variation
Authors:
Ingemar Kaj,
Carina F. Mugal,
Rebekka Müller
Abstract:
We introduce a multi-allele Wright-Fisher model with non-recurrent, reversible mutation and directional selection. In this setting, the allele frequencies at a single locus track the path of a hybrid jump-diffusion process with state space given by the vertex and edge set of a graph. Vertices represent monomorphic population states and edge-positions mark the biallelic proportions of ancestral and…
▽ More
We introduce a multi-allele Wright-Fisher model with non-recurrent, reversible mutation and directional selection. In this setting, the allele frequencies at a single locus track the path of a hybrid jump-diffusion process with state space given by the vertex and edge set of a graph. Vertices represent monomorphic population states and edge-positions mark the biallelic proportions of ancestral and derived alleles during polymorphic segments. We derive the stationary distribution in mutation-selection-drift equilibrium and obtain the expected allele frequency spectrum under large population size scaling. For the extended model with multiple independent loci we derive rigorous upper bounds for a wide class of associated measures of genetic variation. Within this framework we present mathematically precise arguments to conclude that the presence of directional selection reduces the magnitude of genetic variation, as constrained by the bounds for neutral evolution.
△ Less
Submitted 15 February, 2023;
originally announced February 2023.
-
BioSimulators: a central registry of simulation engines and services for recommending specific tools
Authors:
Bilal Shaikh,
Lucian P. Smith,
Dan Vasilescu,
Gnaneswara Marupilla,
Michael Wilson,
Eran Agmon,
Henry Agnew,
Steven S. Andrews,
Azraf Anwar,
Moritz E. Beber,
Frank T. Bergmann,
David Brooks,
Lutz Brusch,
Laurence Calzone,
Kiri Choi,
Joshua Cooper,
John Detloff,
Brian Drawert,
Michel Dumontier,
G. Bard Ermentrout,
James R. Faeder,
Andrew P. Freiburger,
Fabian Fröhlich,
Akira Funahashi,
Alan Garny
, et al. (46 additional authors not shown)
Abstract:
Computational models have great potential to accelerate bioscience, bioengineering, and medicine. However, it remains challenging to reproduce and reuse simulations, in part, because the numerous formats and methods for simulating various subsystems and scales remain siloed by different software tools. For example, each tool must be executed through a distinct interface. To help investigators find…
▽ More
Computational models have great potential to accelerate bioscience, bioengineering, and medicine. However, it remains challenging to reproduce and reuse simulations, in part, because the numerous formats and methods for simulating various subsystems and scales remain siloed by different software tools. For example, each tool must be executed through a distinct interface. To help investigators find and use simulation tools, we developed BioSimulators (https://biosimulators.org), a central registry of the capabilities of simulation tools and consistent Python, command-line, and containerized interfaces to each version of each tool. The foundation of BioSimulators is standards, such as CellML, SBML, SED-ML, and the COMBINE archive format, and validation tools for simulation projects and simulation tools that ensure these standards are used consistently. To help modelers find tools for particular projects, we have also used the registry to develop recommendation services. We anticipate that BioSimulators will help modelers exchange, reproduce, and combine simulations.
△ Less
Submitted 13 March, 2022;
originally announced March 2022.
-
Rapid Fabrication of Low Impedance, 3D Dry Electrodes for Physiological Sensing
Authors:
Ryan Kaveh,
Natalie Tetreault,
Karthik Gopalan,
Julian Maravilla,
Michael Lustig,
Rikky Muller,
Ana C. Arias
Abstract:
Medical electrophysiological sensors that can study the body and diagnose diseases depend on consistently low impedance electrode-skin interfaces. Clinical-standard wet electrodes use hydrogels and skin abrasion to improve the interface and thus the recorded signal quality. These electrodes are challenging to self-administer and impede in-home care. Wearable dry electrodes are more practical; howe…
▽ More
Medical electrophysiological sensors that can study the body and diagnose diseases depend on consistently low impedance electrode-skin interfaces. Clinical-standard wet electrodes use hydrogels and skin abrasion to improve the interface and thus the recorded signal quality. These electrodes are challenging to self-administer and impede in-home care. Wearable dry electrodes are more practical; however, they show higher impedances than wet electrodes and are costly to customize. This work presents a fabrication method for rapidly producing low impedance, anatomically fit dry electrodes that do not require hydrogels. By using electroless copper and gold plating with 3D printing, biocompatible electrodes can be optimized for individuals at a fraction of the cost of existing vacuum deposition-based techniques. Example 3D dry electrodes made with this process are evaluated alongside clinical-standard devices in typical scenarios to compare electrical performance and comfort. The resulting dry electrodes exhibited an average electrode-skin impedance of 66.7 kΩ at 50Hz and DC offset of -20 mV without any hydrogel, which, when area normalized, is within the range achieved by wet electrodes without skin abrasion.
△ Less
Submitted 27 April, 2022; v1 submitted 10 January, 2022;
originally announced January 2022.
-
A MEMS-based optical scanning system for precise, high-speed neural interfacing
Authors:
Cem Yalcin,
Nathan Tessema Ersaro,
M. Meraj Ghanbari,
George Bocchetti,
Sina Faraji Alamouti,
Nick Antipa,
Daniel Lopez,
Nicolas C. Pégard,
Laura Waller,
Rikky Muller
Abstract:
Optical scanning is a prevalent technique for optical neural interfaces where light delivery with high spatial and temporal precision is desired. However, due to the sequential nature of point-scanning techniques, the settling time of optical modulators is a major bottleneck for throughput and limits random-access targeting capabilities. While fast lateral scanners exist, commercially available va…
▽ More
Optical scanning is a prevalent technique for optical neural interfaces where light delivery with high spatial and temporal precision is desired. However, due to the sequential nature of point-scanning techniques, the settling time of optical modulators is a major bottleneck for throughput and limits random-access targeting capabilities. While fast lateral scanners exist, commercially available varifocal elements are constrained to >3ms settling times, limiting the speed of the overall system to hundreds of Hz. Faster focusing methods exist but cannot combine fast operation and dwelling capability with electrical and optical efficiency. Here, we present a varifocal mirror comprised of an array of piston-motion MEMS micromirrors and a custom driver ASIC, offering fast operation with dwelling capability while maintaining high diffraction efficiency. The ASIC features a reconfigurable nonlinear DAC to simultaneously compensate for the built-in nonlinearity of electrostatic actuators and the global process variations in MEMS mirrors. Experimental results demonstrate a wide continuous sweeping range that spans 22 distinctly resolvable depth planes with refresh rates greater than 12 kHz.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Studying Bioluminescence Flashes with the ANTARES Deep Sea Neutrino Telescope
Authors:
N. Reeb,
S. Hutschenreuter,
P. Zehetner,
T. Ensslin,
S. Alves,
M. André,
M. Anghinolfi,
G. Anton,
M. Ardid,
J. -J. Aubert,
J. Aublin,
B. Baret,
S. Basa,
B. Belhorma,
M. Bendahman,
V. Bertin,
S. Biagi,
M. Bissinger,
J. Boumaaza,
M. Bouta,
M. C. Bouwhuis,
H. Brânzaş,
R. Bruijn,
J. Brunner,
J. Busto
, et al. (119 additional authors not shown)
Abstract:
We develop a novel technique to exploit the extensive data sets provided by underwater neutrino telescopes to gain information on bioluminescence in the deep sea. The passive nature of the telescopes gives us the unique opportunity to infer information on bioluminescent organisms without actively interfering with them. We propose a statistical method that allows us to reconstruct the light emissio…
▽ More
We develop a novel technique to exploit the extensive data sets provided by underwater neutrino telescopes to gain information on bioluminescence in the deep sea. The passive nature of the telescopes gives us the unique opportunity to infer information on bioluminescent organisms without actively interfering with them. We propose a statistical method that allows us to reconstruct the light emission of individual organisms, as well as their location and movement. A mathematical model is built to describe the measurement process of underwater neutrino telescopes and the signal generation of the biological organisms. The Metric Gaussian Variational Inference algorithm is used to reconstruct the model parameters using photon counts recorded by the neutrino detectors. We apply this method to synthetic data sets and data collected by the ANTARES neutrino telescope. The telescope is located 40 km off the French coast and fixed to the sea floor at a depth of 2475 m. The runs with synthetic data reveal that we can reliably model the emitted bioluminescent flashes of the organisms. Furthermore, we find that the spatial resolution of the localization of light sources highly depends on the configuration of the telescope. Precise measurements of the efficiencies of the detectors and the attenuation length of the water are crucial to reconstruct the light emission. Finally, the application to ANTARES data reveals the first precise localizations of bioluminescent organisms using neutrino telescope data.
△ Less
Submitted 16 July, 2021;
originally announced July 2021.
-
Wireless User-Generic Ear EEG
Authors:
Ryan Kaveh,
Justin Doong,
Andy Zhou,
Carolyn Schwendeman,
Karthik Gopalan,
Fred Burghardt,
Ana C. Arias,
Michel Maharbiz,
Rikky Muller
Abstract:
In the past few years it has been demonstrated that electroencephalography (EEG) can be recorded from inside the ear (in-ear EEG). To open the door to low-profile earpieces as wearable brain-computer interfaces (BCIs), this work presents a practical in-ear EEG device based on multiple dry electrodes, a user-generic design, and a lightweight wireless interface for streaming data and device programm…
▽ More
In the past few years it has been demonstrated that electroencephalography (EEG) can be recorded from inside the ear (in-ear EEG). To open the door to low-profile earpieces as wearable brain-computer interfaces (BCIs), this work presents a practical in-ear EEG device based on multiple dry electrodes, a user-generic design, and a lightweight wireless interface for streaming data and device programming. The earpiece is designed for improved ear canal contact across a wide population of users and is fabricated in a low-cost and scalable manufacturing process based on standard techniques such as vacuum forming,plasma-treatment, and spray coating. A 2.5x2.5 cm^2 wireless recording module is designed to record and stream data wirelessly to a host computer. Performance was evaluated on three human subjects over three months and compared with clinical-grade wet scalp EEG recordings. Recordings of spontaneous and evoked physiological signals, eye-blinks, alpha rhythm, and the auditory steady-state response (ASSR), are presented. This is the first wireless in-ear EEG to our knowledge to incorporate a dry multielectrode, user-generic design. The user-generic ear EEG recorded a mean alpha modulation of 2.17, outperforming the state-of-the-art in dry electrode in-ear EEG systems.
△ Less
Submitted 29 April, 2020; v1 submitted 1 March, 2020;
originally announced March 2020.
-
StimDust: A mm-scale implantable wireless precision neural stimulator with ultrasonic power and communication
Authors:
David K. Piech,
Benjamin C. Johnson,
Konlin Shen,
M. Meraj Ghanbari,
Ka Yiu Li,
Ryan M. Neely,
Joshua E. Kay,
Jose M. Carmena,
Michel M. Maharbiz,
Rikky Muller
Abstract:
Neural stimulation is a powerful technique for modulating physiological functions and for writing information into the nervous system as part of brain-machine interfaces. Current clinically approved neural stimulators require batteries and are many cubic centimetres in size -- typically much larger than their intended targets. We present a complete wireless neural stimulation system consisting of…
▽ More
Neural stimulation is a powerful technique for modulating physiological functions and for writing information into the nervous system as part of brain-machine interfaces. Current clinically approved neural stimulators require batteries and are many cubic centimetres in size -- typically much larger than their intended targets. We present a complete wireless neural stimulation system consisting of a 1.7 mm3 wireless, batteryless, leadless implantable stimulator (the "mote"), an ultrasonic wireless link for power and bi-directional communication, and a hand-held external transceiver. The mote consists of a piezoceramic transducer, an energy storage capacitor, and a stimulator integrated circuit (IC). The IC harvests ultrasonic power with high efficiency, decodes stimulation parameter downlink data, and generates current-controlled stimulation pulses. Stimulation parameters are time-encoded on the fly through the wireless link rather than being programmed and stored on the mote, reducing power consumption and on-chip memory requirements and enabling complex stimulation protocols with high-temporal resolution and low-latency feedback for use in closed-loop stimulation. Uplink data indicates whether the mote is currently stimulating; it is encoded by the mote via backscatter modulation and is demodulated at the external transceiver. We show that the mote operates at an acoustic intensity that is 7.8% of the FDA limit for diagnostic ultrasound and characterize the acoustic wireless link's robustness to expected real-world misalignment. We demonstrate the in vivo performance of the system with motes acutely implanted with a cuff on the sciatic nerve of anesthetized rats and show highly repeatable stimulation across a wide range of physiological responses.
△ Less
Submitted 14 February, 2020; v1 submitted 19 July, 2018;
originally announced July 2018.
-
A phase field approach to trabecular bone remodeling
Authors:
S. Aland,
F. Stenger,
R. Müller,
M. Kampschulte,
A. C. Langheinrich,
T. El Khassawna,
C. Heiß,
A. Dreutsch,
A. Voigt
Abstract:
We introduce a continuous modeling approach which combines elastic responds of the trabecular bone structure, the concentration of signaling molecules within the bone and a mechanism how this concentration at the bone surface is used for local bone formation and resorption. In an abstract setting bone can be considered as a shape changing structure. For similar problems in materials science phase…
▽ More
We introduce a continuous modeling approach which combines elastic responds of the trabecular bone structure, the concentration of signaling molecules within the bone and a mechanism how this concentration at the bone surface is used for local bone formation and resorption. In an abstract setting bone can be considered as a shape changing structure. For similar problems in materials science phase field approximations have been established as an efficient computational tool. We adapt such an approach for trabecular bone remodeling. It allows for a smooth representation of the trabecular bone structure and drastically reduces computational costs if compared with traditional micro finite element approaches. We demonstrate the advantage of the approach within a minimal model. We quantitatively compare the results with established micro finite element approaches on simple geometries and consider the bone morphology within a bone segment obtained from $μ$CT data of a sheep vertebra with realistic parameters.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
WAND: A 128-channel, closed-loop, wireless artifact-free neuromodulation device
Authors:
Andy Zhou,
Samantha R. Santacruz,
Benjamin C. Johnson,
George Alexandrov,
Ali Moin,
Fred L. Burghardt,
Jan M. Rabaey,
Jose M. Carmena,
Rikky Muller
Abstract:
Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by dynamically delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real-time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and distortion of recorded signals from large, persistent stimulation artifacts. Here, we…
▽ More
Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by dynamically delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real-time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and distortion of recorded signals from large, persistent stimulation artifacts. Here, we describe a device that enables new research applications requiring high-throughput data streaming, low-latency biosignal processing, and truly simultaneous sensing and stimulation. The Wireless Artifact-free Neuromodulation Device (WAND) is a miniaturized, wireless neural interface capable of recording and stimulating on 128 channels with on-board processing to fully cancel stimulation artifacts, detect neural biomarkers, and automatically adjust stimulation parameters in a closed-loop fashion. It combines custom application specific integrated circuits (ASICs), an on-board FPGA, and a low-power bidirectional radio. We validate wireless, long-term recordings of local field potentials (LFP) and real-time cancellation of stimulation artifacts in a behaving nonhuman primate (NHP). We use WAND to demonstrate a closed-loop stimulation paradigm to disrupt movement preparatory activity during a delayed-reach task in a NHP in vivo. This wireless device, leveraging custom ASICs for both neural recording and electrical stimulation modalities, makes possible a neural interface platform technology to significantly advance both neuroscientific discovery and preclinical investigations of stimulation-based therapeutic interventions.
△ Less
Submitted 29 May, 2018; v1 submitted 1 August, 2017;
originally announced August 2017.
-
A computational theory for the classification of natural biosonar targets based on a spike code
Authors:
Rolf Mueller
Abstract:
A computational theory for classification of natural biosonar targets is developed based on the properties of an example stimulus ensemble. An extensive set of echoes (84 800) from four different foliages was transcribed into a spike code using a parsimonious model (linear filtering, half-wave rectification, thresholding). The spike code is assumed to consist of time differences (interspike inte…
▽ More
A computational theory for classification of natural biosonar targets is developed based on the properties of an example stimulus ensemble. An extensive set of echoes (84 800) from four different foliages was transcribed into a spike code using a parsimonious model (linear filtering, half-wave rectification, thresholding). The spike code is assumed to consist of time differences (interspike intervals) between threshold crossings. Among the elementary interspike intervals flanked by exceedances of adjacent thresholds, a few intervals triggered by disjoint half-cycles of the carrier oscillation stand out in terms of resolvability, visibility across resolution scales and a simple stochastic structure (uncorrelatedness). They are therefore argued to be a stochastic analogue to edges in vision. A three-dimensional feature vector representing these interspike intervals sustained a reliable target classification performance (0.06% classification error) in a sequential probability ratio test, which models sequential processing of echo trains by biological sonar systems. The dimensions of the representation are the first moments of duration and amplitude location of these interspike intervals as well as their number. All three quantities are readily reconciled with known principles of neural signal representation, since they correspond to the center of gravity of excitation on a neural map and the total amount of excitation.
△ Less
Submitted 26 May, 2003; v1 submitted 2 August, 2002;
originally announced August 2002.