-
Constructed wetlands operated as bioelectrochemical systems for the removal of organic micropollutants
Authors:
M. Hartl,
M. J. García-Galán,
V. Matamoros,
M. Fernández-Gatell,
D. P. L. Rousseau,
G. Du Laing,
M. Garfí,
J. Puigagut
Abstract:
The removal of organic micropollutants (OMPs) has been investigated in constructed wetlands (CWs) operated as bioelectrochemical systems (BES). The operation of CWs as BES (CW-BES), either in the form of microbial fuel cells (MFC) or microbial electrolysis cells (MEC), has only been investigated in recent years. The presented experiment used CW meso-scale systems applying a realistic horizontal fl…
▽ More
The removal of organic micropollutants (OMPs) has been investigated in constructed wetlands (CWs) operated as bioelectrochemical systems (BES). The operation of CWs as BES (CW-BES), either in the form of microbial fuel cells (MFC) or microbial electrolysis cells (MEC), has only been investigated in recent years. The presented experiment used CW meso-scale systems applying a realistic horizontal flow regime and continuous feeding of real urban wastewater spiked with four OMPs (pharmaceuticals), namely carbamazepine (CBZ), diclofenac (DCF), ibuprofen (IBU) and naproxen (NPX). The study evaluated the removal efficiency of conventional CW systems (CW-control) as well as CW systems operated as closed-circuit MFCs (CW-MFCs) and MECs (CW-MECs). Although a few positive trends were identified for the CW-BES compared to the CW-control (higher average CBZ, DCF and NPX removal by 10-17% in CW-MEC and 5% in CW-MFC), these proved to be not statistically significantly different. Mesoscale experiments with real wastewater could thus not confirm earlier positive effects of CW-BES found under strictly controlled laboratory conditions with synthetic wastewaters.
△ Less
Submitted 14 January, 2021;
originally announced January 2021.
-
Contaminants removal and bacterial activity enhancement along the flow path of constructed wetland microbial fuel cells
Authors:
Marco Hartl,
Diego F. Bedoya-Ríos,
Marta Fernández-Gatell,
Diederik P. L. Rousseau,
Gijs Du Laing,
Marianna Garfí,
Jaume Puigagut
Abstract:
Microbial fuel cells implemented in constructed wetlands (CW-MFCs), albeit a relatively new technology still under study, have shown to improve treatment efficiency of urban wastewater. So far the vast majority of CW-MFC systems investigated were designed as lab-scale systems working under rather unrealistic hydraulic conditions using synthetic wastewater. The main objective of this work was to qu…
▽ More
Microbial fuel cells implemented in constructed wetlands (CW-MFCs), albeit a relatively new technology still under study, have shown to improve treatment efficiency of urban wastewater. So far the vast majority of CW-MFC systems investigated were designed as lab-scale systems working under rather unrealistic hydraulic conditions using synthetic wastewater. The main objective of this work was to quantify CW-MFCs performance operated under different conditions in a more realistic setup using meso-scale systems with horizontal flow fed with real urban wastewater. Operational conditions tested were organic loading rate (4.9+-1.6, 6.7+-1.4 and 13.6+-3.2 g COD/m2.day) and hydraulic regime (continuous vs intermittent feeding) as well as different electrical connections: CW control (conventional CW without electrodes), open-circuit CW-MFC (external circuit between anode and cathode not connected) and closed-circuit CW-MFC (external circuit connected). Eight horizontal subsurface flow CWs were operated for about four months. Each wetland consisted of a PVC reservoir of 0.193 m2 filled with 4/8 mm granitic riverine gravel. All wetlands had intermediate sampling points for gravel and interstitial liquid sampling. The CW-MFCs were designed as three MFCs incorporated one after the other along the flow path of the CWs. Results showed no significant differences between tested organic loading rates, hydraulic regimes or electrical connections, however, on average, systems operated in closed-circuit CW-MFC mode under continuous flow outperformed the other experimental conditions. Closed-circuit CW-MFC compared to conventional CW control systems showed around 5% and 22% higher COD and ammonium removal, respectively. Correspondingly, overall bacteria activity, as measured by the fluorescein diacetate technique, was higher (4% to 34%) in closed-circuit systems when compared to CW control systems.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Fate of priority pharmaceuticals and their main metabolites and transformation products in microalgae-based wastewater treatment systems
Authors:
Maria Jesus Garcia-Galan,
Larissa Arashiro,
Lucia H. M. L. M. Santos,
Sara Insa,
Sara Rodriguez-Mozaz,
Damia Barcelo,
Ivet Ferrer,
Marianna Garfi
Abstract:
The present study evaluates the removal capacity of two high rate algae ponds (HRAPs) to eliminate 12 pharmaceuticals (PhACs) and 26 of their corresponding main metabolites and transformation products. The efficiency of these ponds, operating with and without primary treatment, was compared in order to study their capacity under the best performance conditions (highest solar irradiance). Concentra…
▽ More
The present study evaluates the removal capacity of two high rate algae ponds (HRAPs) to eliminate 12 pharmaceuticals (PhACs) and 26 of their corresponding main metabolites and transformation products. The efficiency of these ponds, operating with and without primary treatment, was compared in order to study their capacity under the best performance conditions (highest solar irradiance). Concentrations of all the target compounds were determined in both water and biomass samples. Removal rates ranged from moderate (40-60%) to high (>60%) for most of them, with the exception of the psychiatric drugs carbamazepine, the beta-blocking agent metoprolol and its metabolite, metoprolol acid. O-desmethylvenlafaxine, despite its very low biodegradability in conventional wastewater treatment plants, was removed to certain extent (13-39%) Biomass concentrations suggested that bioadsorption/bioaccumulation to microalgae biomass was decisive regarding the elimination of some non-biodegradable compounds such as venlafaxine and its main metabolites. HRAP treatment with and without primary treatment did not yield significant differences in terms of PhACs removal efficiency. The implementation of HRAPs as secondary treatment is a viable alternative to CAS in terms of overall wastewater treatment (including organic micropollutants), with generally higher removal performances and implying a green, low-cost and more sustainable technology.
△ Less
Submitted 15 March, 2020;
originally announced March 2020.
-
Life Cycle Assessment of high rate algal ponds for wastewater treatment and resource recovery
Authors:
Larissa Terumi Arashiro,
Neus Montero,
Ivet Ferrer,
Francisco Gabriel Acien,
Cintia Gomez,
Marianna Garfi
Abstract:
The aim of this study was to assess the potential environmental impacts associated with high rate algal ponds (HRAP) systems for wastewater treatment and resource recovery in small communities. To this aim, a Life Cycle Assessment (LCA) and an economic assessment were carried out evaluating two alternatives: i) a HRAPs system for wastewater treatment where microalgal biomass is valorised for energ…
▽ More
The aim of this study was to assess the potential environmental impacts associated with high rate algal ponds (HRAP) systems for wastewater treatment and resource recovery in small communities. To this aim, a Life Cycle Assessment (LCA) and an economic assessment were carried out evaluating two alternatives: i) a HRAPs system for wastewater treatment where microalgal biomass is valorised for energy recovery (biogas production); ii) a HRAPs system for wastewater treatment where microalgal biomass is reused for nutrients recovery (biofertiliser production). Additionally, both alternatives were compared to a typical small-sized activated sludge system. The results showed that HRAPs system coupled with biogas production appeared to be more environmentally friendly than HRAPs system coupled with biofertiliser production in the climate change, ozone layer depletion, photochemical oxidant formation, and fossil depletion impact categories. Different climatic conditions have strongly influenced the results obtained in the eutrophication and metal depletion impact categories, with the HRAPs system located where warm temperatures and high solar radiation are predominant showing lower impact. In terms of costs, HRAPs systems seemed to be more economically feasible when combined with biofertiliser production instead of biogas.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Natural pigments from microalgae grown in industrial wastewater
Authors:
Larissa T. Arashiro,
Maria Boto-Ordonez,
Stijn W. H. Van Hulle,
Ivet Ferrer,
Marianna Garfi,
Diederik P. L. Rousseau
Abstract:
The aim of this study was to investigate the cultivation of Nostoc sp., Arthrospira platensis and Porphyridium purpureum in industrial wastewater to produce phycobiliproteins. Initially, light intensity and growth medium composition were optimized, indicating that light conditions influenced the phycobiliproteins production more than the medium composition. Conditions were then selected, according…
▽ More
The aim of this study was to investigate the cultivation of Nostoc sp., Arthrospira platensis and Porphyridium purpureum in industrial wastewater to produce phycobiliproteins. Initially, light intensity and growth medium composition were optimized, indicating that light conditions influenced the phycobiliproteins production more than the medium composition. Conditions were then selected, according to biomass growth, nutrients removal and phycobiliproteins production, to cultivate these microalgae in food-industry wastewater. The three species could efficiently remove up to 98%, 94% and 100% of COD, inorganic nitrogen and PO43--P, respectively. Phycocyanin, allophycocyanin and phycoerythrin were successfully extracted from the biomass reaching concentrations up to 103, 57 and 30 mg/g dry weight, respectively. Results highlight the potential use of microalgae for industrial wastewater treatment and related high-value phycobiliproteins recovery.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
The effect of primary treatment of wastewater in high rate algal pond systems: biomass and bioenergy recovery
Authors:
Larissa T. Arashiro,
Ivet Ferrer,
Diederik P. L. Rousseau,
Stijn W. H. Van Hulle,
Marianna Garfi
Abstract:
The aim of this study was to assess the effect of primary treatment on the performance of two pilot-scale high rate algal ponds (HRAPs) treating urban wastewater, considering their treatment efficiency, biomass productivity, characteristics and biogas production potential. Results indicated that the primary treatment did not significantly affect the wastewater treatment efficiency (NH4+-N removal…
▽ More
The aim of this study was to assess the effect of primary treatment on the performance of two pilot-scale high rate algal ponds (HRAPs) treating urban wastewater, considering their treatment efficiency, biomass productivity, characteristics and biogas production potential. Results indicated that the primary treatment did not significantly affect the wastewater treatment efficiency (NH4+-N removal of 93 and 91% and COD removal of 62 and 65% in HRAP with and without primary treatment, respectively). The HRAP without primary treatment had higher biodiversity and productivity (18 vs. 16 g VSS/m2d). Biomass from both systems presented good settling capacity. Results of biochemical methane potential test showed that co-digesting microalgae and primary sludge led to higher methane yields (238 - 258 mL CH4/g VS) compared with microalgae mono-digestion (189 - 225 mL CH4/g VS). Overall, HRAPs with and without primary treatment seem to be appropriate alternatives for combining wastewater treatment and bioenergy recovery.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.