-
First results on monolithic CMOS detector with internal gain
Authors:
U. Follo,
G. Gioachin,
C. Ferrero,
M. Mandurrino,
M. Bregant,
S. Bufalino,
F. Carnesecchi,
D. Cavazza,
M. Colocci,
T. Corradino,
M. Da Rocha Rolo,
G. Di Nicolantonio,
S. Durando,
G. Margutti,
M. Mignone,
R. Nania,
L. Pancheri,
A. Rivetti,
B. Sabiu,
G. G. A. de Souza,
S. Strazzi,
R. Wheadon
Abstract:
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the elect…
▽ More
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Optimization of GEM detectors for applications in X-ray fluorescence imaging
Authors:
Geovane G. A. de Souza,
Hugo Natal da Luz,
Marco Bregant
Abstract:
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation interactions with gases, the energy resolution limits after charge multiplication for 6keV X-ray photons in Ar/CO$_2$(70/30) and Kr/CO$_2$(90/10) were calculated,…
▽ More
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation interactions with gases, the energy resolution limits after charge multiplication for 6keV X-ray photons in Ar/CO$_2$(70/30) and Kr/CO$_2$(90/10) were calculated, obtaining energy resolutions of 15.4(4)% and 14.6(2)% respectively. The detector design was also studied to reduce the presence of escape peaks and complement a model to evaluate the inevitable X-ray fluorescence of copper generated by the conductive materials inside the detector.
△ Less
Submitted 30 September, 2024; v1 submitted 23 April, 2024;
originally announced April 2024.
-
A data acquisition and reconstruction software for SAMPA-SRS integration
Authors:
G. G. A. de Souza,
T. S. Abelha,
T. B. Saramela,
A. F. V. Cortez,
H. N. da Luz,
C. G. Penteado,
M. Bregant
Abstract:
In this work we present the latest developments in the SAMPA-SRS integration. A software was developed to improve the acquisition configuration, acquisition, and decoding of the data. The complete framework was tested using a triple GEM-based position sensitive detector for X-rays. The detector was operated in Ar/CO$_2$ (70/30) in continuous flow, at atmospheric pressure and made use of a 1 dimens…
▽ More
In this work we present the latest developments in the SAMPA-SRS integration. A software was developed to improve the acquisition configuration, acquisition, and decoding of the data. The complete framework was tested using a triple GEM-based position sensitive detector for X-rays. The detector was operated in Ar/CO$_2$ (70/30) in continuous flow, at atmospheric pressure and made use of a 1 dimension strip readout (200$μ$m wide strips at a pitch of 400$μ$m) for charge collection. With this detector a position resolution of better than 833$μ$m was obtained, with an energy resolution of 14.2% ($σ/E$) for 5.9keV.
△ Less
Submitted 8 May, 2023; v1 submitted 20 March, 2023;
originally announced March 2023.
-
Double-GEM based thermal neutron detector prototype
Authors:
L. A. Serra Filho,
R. Felix dos Santos,
G. G. A. de Souza,
M. M. M. Paulino,
F. A. Souza,
M. Moralles,
H. Natal da Luz,
M. Bregant,
M. G. Munhoz,
Chung-Chuan Lai,
Carina Höglund,
Per-Olof Svensson,
Linda Robinson,
Richard Hall-Wilton
Abstract:
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a $^{10}$B$_4$C layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of 3.14(10) %, agreeing within 2.7 $σ$ with the experimen…
▽ More
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a $^{10}$B$_4$C layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of 3.14(10) %, agreeing within 2.7 $σ$ with the experimental and analytic detection efficiencies obtained by the detector when tested in a 41.8 meV thermal neutron beam. The detector is position sensitive, equipped with a 256+256 strip readout connected to resistive chains, and achieves a spatial resolution better than 3 mm. The gain stability over time was also measured with a fluctuation of about 0.2 %h$^{-1}$ of the signal amplitude. A simple data acquisition with only 5 electronic channels is sufficient to operate this detector.
△ Less
Submitted 19 July, 2022; v1 submitted 14 May, 2022;
originally announced May 2022.
-
Characterization of a triple-GEM position sensitive detector for X-ray fluorescence imaging
Authors:
Geovane G. A. de Souza,
Hugo Natal da Luz
Abstract:
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above $10^4$, energy resoluti…
▽ More
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above $10^4$, energy resolution of 15.28% (FWHM) for 5.9keV X-rays, and position resolution of 1.2mm, while operating in Ar/CO$_2$(90/10) at atmospheric pressure.
△ Less
Submitted 17 April, 2019;
originally announced April 2019.
-
XRF element localization with a triple GEM detector using resistive charge division
Authors:
Geovane G. A. de Souza,
Hugo Natal da Luz
Abstract:
In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with resistive chains applied to the strip readout, which allow to use only five electronic channels: two for each dimension and a fifth for energy and trigger. The…
▽ More
In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with resistive chains applied to the strip readout, which allow to use only five electronic channels: two for each dimension and a fifth for energy and trigger. The corrections applied to the energy spectra to compensate for small changes in the signal amplitude and also differences in gain throughout the sensitive area are described and the clear improvement of the energy resolution is shown. To take advantage of the simultaneous sensitivity to the energy and to the position of interaction, a color scale matching the energy spectrum to the RGB range was applied, resulting in images where the color has a direct correspondence to the energy in each pixel and the intensity is reflected by the brightness of the image. The results obtained with four different color pigments are shown.
△ Less
Submitted 20 May, 2019; v1 submitted 9 January, 2019;
originally announced January 2019.