Skip to main content

Showing 1–5 of 5 results for author: de Oliveira, V S

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.08244  [pdf

    physics.chem-ph

    Measurement and assignment of J = 5 to 9 rotational energy levels in the 9070-9370 cm$^{-1}$ range of methane using optical frequency comb double-resonance spectroscopy

    Authors: Adrian Hjältén, Vinicius Silva de Oliveira, Isak Silander, Andrea Rosina, Michael Rey, Lucile Rutkowski, Grzegorz Soboń, Kevin K. Lehmann, Aleksandra Foltynowicz

    Abstract: We use optical-optical double-resonance (OODR) spectroscopy with a continuous wave (CW) pump and a cavity-enhanced frequency comb probe to measure high rotational energy levels of methane in the upper part of the triacontad polyad (P6). A high-power CW optical parametric oscillator, tunable around 3000 cm$^{-1}$, is consecutively locked to the P(7, A$_2$), Q(7, A$_2$), R(7, A$_2$), and Q(6, F$_2$)… ▽ More

    Submitted 12 June, 2024; originally announced June 2024.

  2. Sub-Doppler optical-optical double-resonance spectroscopy using a cavity-enhanced frequency comb probe

    Authors: Vinicius Silva de Oliveira, Isak Silander, Lucile Rutkowski, Grzegorz Soboń, Ove Axner, Kevin K. Lehmann, Aleksandra Foltynowicz

    Abstract: Accurate parameters of molecular hot-band transitions, i.e., those starting from vibrationally excited levels, are needed to accurately model high-temperature spectra in astrophysics and combustion, yet laboratory spectra measured at high temperatures are often unresolved and difficult to assign. Optical-optical double-resonance (OODR) spectroscopy allows the measurement and assignment of individu… ▽ More

    Submitted 20 August, 2024; v1 submitted 6 July, 2023; originally announced July 2023.

    Comments: Addendum added on Aug 20, 2024, containing comparison of experimental line positions and intensities to new predictions from an effective Hamiltonian and the ExoMol database

    Journal ref: Nature Communications 15, 161 (2024)

  3. Self-broadening and self-shift in the $\mathbf{3ν_{2}}$ band of ammonia from mid-infrared-frequency-comb spectroscopy

    Authors: Guang Yang, Vinicius Silva de Oliveira, Dominic Laumer, Christoph M. Heyl, Andrey Yachmenev, Ingmar Hartl, Jochen Küpper

    Abstract: We report the broadband absorption spectrum of the $3ν_{2}$ band of $^{14}$NH$_{3}$ near 4 $μm$. The data were recorded using a mid-infrared frequency comb coupled to a homebuilt Fourier-transform spectrometer with a resolution of 0.00501 $cm^{-1}$. Line positions, line intensities, self-broadening, and self-shift parameters for six rovibrational lines were determined at room temperature ($T=296$… ▽ More

    Submitted 17 January, 2023; v1 submitted 9 May, 2022; originally announced May 2022.

  4. Sub-Doppler Double-Resonance Spectroscopy of Methane Using a Frequency Comb Probe

    Authors: Aleksandra Foltynowicz, Lucile Rutkowski, Isak Silander, Alexandra C. Johansson, Vinicius Silva de Oliveira, Ove Axner, Grzegorz Soboń, Tadeusz Martynkien, Paweł Mergo, Kevin K. Lehmann

    Abstract: We report the measurement of sub-Doppler double-resonance transitions in methane using a 3.3 $μ$m continuous wave optical parametric oscillator to pump transitions in the fundamental $ν_3$ band and a 1.67 $μ$m frequency comb to probe ladder-type transitions in the 3$ν_3$ band over 200 cm$^{-1}$ of bandwidth. We detected 36 ladder-type resonances for 9 pumped transitions with average center frequen… ▽ More

    Submitted 23 January, 2020; originally announced January 2020.

    Journal ref: Phys. Rev. Lett. 126, 063001 (2021)

  5. arXiv:1904.02611  [pdf, other

    physics.optics

    Intensity Noise Optimization of a Mid-Infrared Frequency Comb Difference Frequency Generation Source

    Authors: Vinicius Silva de Oliveira, Axel Ruehl, Piotr Masłowski, Ingmar Hartl

    Abstract: We experimentally demonstrate in a difference-frequency generation mid-infrared frequency comb source the effect of temporal overlap between pump- and signal- pulse to the relative intensity noise (RIN) of the idler pulse. When scanning the temporal delay between our 130 fs long signal- and pump pulses, we observe a RIN minimum with a 3 dB width of 20 fs delay and an RIN increase of 20 dB in 40 fs… ▽ More

    Submitted 4 April, 2019; originally announced April 2019.