-
Exploring Eco-Friendly Gas Mixtures for Resistive Plate Chambers: A Comprehensive Study on Performance and Aging
Authors:
The RPC ECOGas@GIF++ collaboration,
:,
L. Quaglia,
M. Abbrescia,
G. Aielli,
R. Aly,
M. C. Arena,
M. Barroso,
L. Benussi,
S. Bianco,
D. Boscherini,
F. Bordon,
A. Bruni,
S. Buontempo,
M. Busato,
P. Camarri,
R. Cardarelli,
L. Congedo,
D. De Jesus Damiao,
M. De Serio,
A. Di Ciaccio,
L. Di Stante,
P. Dupieux,
J. Eysermans,
A. Ferretti
, et al. (35 additional authors not shown)
Abstract:
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, invo…
▽ More
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global warming potential (GWP) of 1430. To comply with European regulations and explore environmentally friendly alternatives, the RPC EcoGas@GIF++ collaboration, involving ALICE, ATLAS, CMS, LHCb/SHiP, and EP-DT communities, has undertaken intensive R\&D efforts to explore new gas mixtures for RPC technology.
A leading alternative under investigation is HFO1234ze, boasting a low GWP of 6 and demonstrating reasonable performance compared to R-134a. Over the past few years, RPC detectors with slightly different characteristics and electronics have been studied using HFO and CO$_{2}$-based gas mixtures at the CERN Gamma Irradiation Facility. An aging test campaign was launched in August 2022, and during the latest test beam in July 2023, all detector systems underwent evaluation. This contribution will report the results of the aging studies and the performance evaluations of the detectors with and without irradiation.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Optimization and performance of the CryoCube detector for the future RICOCHET low-energy neutrino experiment
Authors:
T. Salagnac,
J. Billard,
J. Colas,
D. Chaize,
M. De Jesus,
L. Dumoulin,
J. -B. Filippini,
J. Gascon,
A. Juillard,
H. Lattaud,
S. Marnieros,
D. Misiak,
C. Oriol,
L. Vagneron,
the RICOCHET collaboration
Abstract:
The RICOCHET reactor neutrino observatory is planned to be installed at Institut Laue-Langevin starting in mid-2022. The scientific goal of the RICOCHET collaboration is to perform a low-energy and percentage-precision CENNS measurement in order to explore exotic physics scenarios beyond the standard model. To that end, RICOCHET will host two cryogenic detector arrays : the CryoCube (Ge target) an…
▽ More
The RICOCHET reactor neutrino observatory is planned to be installed at Institut Laue-Langevin starting in mid-2022. The scientific goal of the RICOCHET collaboration is to perform a low-energy and percentage-precision CENNS measurement in order to explore exotic physics scenarios beyond the standard model. To that end, RICOCHET will host two cryogenic detector arrays : the CryoCube (Ge target) and the Q-ARRAY (Zn target), both with unprecedented sensitivity to O(10)eV nuclear recoils. The CryoCube will be composed of 27 Ge crystals of 38g instrumented with NTD-Ge thermal sensor as well as aluminum electrodes operated at 10mK in order to measure both the ionization and the heat energies arising from a particle interaction. To be a competitive CENNS detector, the CryoCube array is designed with the following specifications : a low energy threshold ($\sim 50$eV), the ability to identify and reject with a high efficiency the overwhelming electromagnetic backgrounds (gamma, betas, X-rays) and a sufficient payload ($\sim 1$kg). After a brief introduction of the future RICOCHET experiment and its CryoCube, the current works and first performance results on the optimization of the heat channel and the electrode designs will be presented. We conclude with a preliminary estimation of the CryoCube sensitivity to the CENNS signal within RICOCHET.
△ Less
Submitted 24 November, 2021;
originally announced November 2021.
-
HEMT-based 1K front-end electronics for the heat and ionization Ge CryoCube of the future RICOCHET CE$ν$NS experiment
Authors:
G. Baulieu,
J. Billard,
G. Bres,
J-L Bret,
D. Chaize,
J. Colas,
Q. Dong,
O. Exshaw,
C. Guerin,
S. Ferriol,
J-B Filippini,
M. De Jesus,
Y. Jin,
A. Juillard,
J. Lamblin,
H. Lattaud,
J. Minet,
D. Misiak,
A. Monfardini,
F. Rarbi,
T. Salagnac,
L. Vagneron,
the RICOCHET Collaboration
Abstract:
The RICOCHET reactor neutrino observatory is planned to be installed at the Laue Langevin Institute (ILL) starting mid-2022. Its scientific goal is to perform a low-energy and high precision measurement of the coherent elastic neutrino-nucleus scattering (CE$ν$NS) spectrum in order to explore exotic physics scenarios. RICOCHET will host two cryogenic detector arrays: the CryoCube (Ge target) and t…
▽ More
The RICOCHET reactor neutrino observatory is planned to be installed at the Laue Langevin Institute (ILL) starting mid-2022. Its scientific goal is to perform a low-energy and high precision measurement of the coherent elastic neutrino-nucleus scattering (CE$ν$NS) spectrum in order to explore exotic physics scenarios. RICOCHET will host two cryogenic detector arrays: the CryoCube (Ge target) and the Q-ARRAY (Zn target), operated at 10 mK. The 1 kg Ge CryoCube will consist of 27 Ge crystals instrumented with NTD-Ge thermal sensors and charge collection electrodes for a simultaneous heat and ionization readout to reject the electromagnetic backgrounds (gamma, beta, x-rays). We present the status of its front-end electronics. The first stage of amplification is made of High Electron Mobility Transistor (HEMT) developed by CNRS/C2N laboratory, optimized to achieve ultra-low noise performance at 1K with a dissipation as low as 15 $μ$W per channel. Our noise model predicts that 10 eV heat and 20 eVee RMS baseline resolutions are feasible with a high dynamic range for the deposited energy (up to 10 MeV) thanks to loop amplification schemes. Such resolutions are mandatory to have a high discrimination power between nuclear and electron recoils at the lowest energies.
△ Less
Submitted 30 March, 2023; v1 submitted 19 November, 2021;
originally announced November 2021.
-
Recent Advances in Diamond Detectors
Authors:
W. Trischuk,
the RD42 collaboration
Abstract:
With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2012, ATLAS and CMS are planning for detector upgrades for their innermost layers requiring radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is now plann…
▽ More
With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2012, ATLAS and CMS are planning for detector upgrades for their innermost layers requiring radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is now planned for all LHC experiments. This material is now being considered as an alternate sensor for use very close to the interaction region of the super LHC where the most extreme radiation conditions will exist. Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single-crystal chemical vapor deposition diamond sensors to the highest fluences available. We present beam test results of chemical vapor deposition diamond up to fluences of 1.8 x 10^16 protons/cm^2 showing that both polycrystalline and single-crystal chemical vapor deposition diamonds follow a single damage curve allowing one to extrapolate their performance as a function of dose.
△ Less
Submitted 20 October, 2008;
originally announced October 2008.