Skip to main content

Showing 1–7 of 7 results for author: Zuñiga-Reyes, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:2503.10383  [pdf, other

    physics.ins-det

    Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment

    Authors: The DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, G. R. Araujo, D. J. Auty, M. Baldwin, M. Batygov, B. Beltran, H. Benmansour, M. A. Bigentini, C. E. Bina, J. Bonatt, W. M. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti , et al. (139 additional authors not shown)

    Abstract: In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial volume that enhances dark matter candidate events identification. This paper describes three distinct position reconstruction algorithms employed by DEAP-3600, leveraging the spatial and temporal information provided by… ▽ More

    Submitted 13 March, 2025; originally announced March 2025.

    Comments: 24 pages, 16 figures

  2. arXiv:2501.13196  [pdf, other

    nucl-ex physics.ins-det

    Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

    Authors: DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, D. J. Auty, M. Batygov, B. Beltran, C. E. Bina, W. M. Bonivento, M. G. Boulay, J. F. Bueno, M. Cadeddu, B. Cai, M. Cárdenas-Montes, Y. Chen, S. Choudhary, B. T. Cleveland, R. Crampton, S. Daugherty, P. DelGobbo, P. Di Stefano, G. Dolganov, L. Doria , et al. (89 additional authors not shown)

    Abstract: The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant s… ▽ More

    Submitted 9 April, 2025; v1 submitted 22 January, 2025; originally announced January 2025.

    Comments: 11 pages, 8 figures

  3. arXiv:2410.07241  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

    Authors: E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, H. Hawley-Herrera, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (7 additional authors not shown)

    Abstract: A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at… ▽ More

    Submitted 12 February, 2025; v1 submitted 7 October, 2024; originally announced October 2024.

    Comments: 11 pages, 7 figures

    Journal ref: Phys. Rev. D 111, 032002 (2025)

  4. arXiv:2302.14639  [pdf, other

    physics.ins-det hep-ex

    Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

    Authors: P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, G. R. Araujo, D. J. Auty, M. Baldwin, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen , et al. (125 additional authors not shown)

    Abstract: The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi… ▽ More

    Submitted 10 October, 2023; v1 submitted 27 February, 2023; originally announced February 2023.

    Journal ref: Eur. Phys. J. C 83, 642 (2023)

  5. arXiv:2103.12202  [pdf, other

    physics.ins-det astro-ph.IM

    Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

    Authors: The DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, D. J. Auty, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, J. M. Corning , et al. (104 additional authors not shown)

    Abstract: The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar… ▽ More

    Submitted 6 April, 2021; v1 submitted 22 March, 2021; originally announced March 2021.

    Comments: 14 pages, 9 figures

    Journal ref: Eur. Phys. J. C 81, 823 (2021)

  6. arXiv:2101.08785  [pdf, other

    hep-ex hep-ph nucl-ex physics.ins-det

    Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments

    Authors: L. J. Flores, Eduardo Peinado, E. Alfonso-Pita, K. Allen, M. Baker, E. Behnke, M. Bressler, K. Clark, R. Coppejans, C. Cripe, M. Crisler, C. E. Dahl, A. de St. Croix, D. Durnford, P. Giampa, O. Harris, P. Hatch, H. Hawley, C. M. Jackson, Y. Ko, C. Krauss, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott , et al. (9 additional authors not shown)

    Abstract: The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig… ▽ More

    Submitted 26 May, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Comments: 9 pages, 5 figures. v2: figures added, minor changes. Matches published version

    Journal ref: Phys. Rev. D 103, 091301 (2021)

  7. The liquid-argon scintillation pulseshape in DEAP-3600

    Authors: The DEAP collaboration, P. Adhikari, R. Ajaj, G. R. Araujoand M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. J. Daughertyand K. Dering, L. Doria, F. A. Duncan andM. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, R. Gagnon , et al. (76 additional authors not shown)

    Abstract: DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed… ▽ More

    Submitted 8 June, 2020; v1 submitted 27 January, 2020; originally announced January 2020.

    Journal ref: Eur. Phys. J. C 80, 303 (2020)