-
Increasing the rate capability for the cryogenic stopping cell of the FRS Ion Catcher
Authors:
J. W. Zhao,
D. Amanbayev,
T. Dickel,
I. Miskun,
W. R. Plass,
N. Tortorelli,
S. Ayet San Andres,
Soenke Beck,
J. Bergmann,
Z. Brencic,
P. Constantin,
H. Geissel,
F. Greiner,
L. Groef,
C. Hornung,
N. Kuzminzuk,
G. Kripko-Koncz,
I. Mardor,
I. Pohjalainen,
C. Scheidenberger,
P. G. Thirolf,
S. Bagchi,
E. Haettner,
E. Kazantseva,
D. Kostyleva
, et al. (23 additional authors not shown)
Abstract:
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stopping cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Sup…
▽ More
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stopping cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Super-FRS, where exotic nuclei will be produced at unprecedented rates making it possible to go towards the extremes of the nuclear chart. Therefore, it is essential to efficiently extract thermalized exotic nuclei from the CSC under high beam rate conditions, in order to use the rare exotic nuclei which come as cocktail beams. The extraction efficiency dependence on the intensity of the impinging beam into the CSC was studied with a primary beam of 238U and its fragments. Tests were done with two different versions of the DC electrode structure inside the cryogenic chamber, the standard 1 m long and a short 0.5 m long DC electrode. In contrast to the rate capability of 10^4 ions/s with the long DC electrode, results show no extraction efficiency loss up to the rate of 2x10^5 ions/s with the new short DC electrode. This order of magnitude increase of the rate capability paves the way for new experiments at the FRS-IC, including exotic nuclei studies with in-cell multi-nucleon transfer reactions. The results further validate the design concept of the CSC for the Super-FRS, which was developed to effectively manage beams of even higher intensities.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Improvement of charge resolution for radioactive heavy ions at relativistic energies using a hybrid detector system
Authors:
J. W. Zhao,
B. H. Sun,
L. C. He,
G. S. Li,
W. J. Lin,
C. Y. Liu,
Z. Liu,
C. G. Lu,
D. P. Shen,
Y. Z. Sun,
Z. Y. Sun,
I. Tanihata,
S. Terashima,
D. T. Tran,
F. Wang,
J. Wang,
S. T. Wang,
X. L. Wei,
X. D. Xu,
L. H. Zhu,
J. C. Zhang,
X. H. Zhang,
Y. Zhang,
Z. T. Zhou,
Z. T. Zhou
Abstract:
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present a…
▽ More
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present an approach on improving the resolution of charge measurement for heavy ions by using the abundant energy loss information from different types of existing detectors along the beam line. Without altering the beam line and detectors, this approach can improve the charge resolution by more than 12\% relative to the multiple sampling ionization chamber of the best resolution.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Luminosity measurements for the R scan experiment at BESIII
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (405 additional authors not shown)
Abstract:
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measur…
▽ More
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measured at the different c.m. energies, individually. The results are the important inputs for R value and $J/ψ$ resonance parameter measurements.
△ Less
Submitted 11 February, 2017;
originally announced February 2017.
-
Development of a fast plastic scintillation detector with time resolution of less than 10 ps
Authors:
J. W. Zhao,
B. H. Sun,
I. Tanihata,
S. Terashima,
L. H. Zhu,
A. Enomoto,
D. Nagae,
T. Nishimura,
S. Omika,
A. Ozawa,
Y. Takeuchi,
T. Yamaguchi
Abstract:
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, t…
▽ More
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps (σ) has been achieved for detectors with an area size of 3x1 cm2. It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than currently available TDC. Simultaneously measurements of both time and pulse height are very valuable for correction of time-walk effect.
△ Less
Submitted 30 January, 2016;
originally announced February 2016.
-
Measurements of Baryon Pair Decays of $χ_{cJ}$ Mesons
Authors:
M. Ablikim,
M. N. Achasov,
O. Albayrak,
D. J. Ambrose,
F. F. An,
Q. An,
J. Z. Bai,
Y. Ban,
J. Becker,
J. V. Bennett,
M. Bertani,
J. M. Bian,
E. Boger,
O. Bondarenko,
I. Boyko,
R. A. Briere,
V. Bytev,
X. Cai,
O. Cakir,
A. Calcaterra,
G. F. Cao,
S. A. Cetin,
J. F. Chang,
G. Chelkov,
G. Chen
, et al. (326 additional authors not shown)
Abstract:
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$,…
▽ More
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$, $(20.8 \pm 1.6 \pm 2.3)\times 10^{-5}$; $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{0}\barΣ^{0})$ = $(47.8 \pm 3.4 \pm 3.9)\times 10^{-5}$, $(3.8 \pm 1.0 \pm 0.5)\times 10^{-5}$, $(4.0 \pm 1.1 \pm 0.5) \times 10^{-5}$; and $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{+}\barΣ^{-})$ = $(45.4 \pm 4.2 \pm 3.0)\times 10^{-5}$, $(5.4 \pm 1.5 \pm 0.5)\times 10^{-5}$, $(4.9 \pm 1.9 \pm 0.7)\times 10^{-5}$, where the first error is statistical and the second is systematic. Upper limits on the branching fractions for the decays of $χ_{c1,2}\rightarrowΣ^{0}\barΣ^{0}$, $Σ^{+}\barΣ^{-}$, are estimated to be $\cal{B}$$(χ_{c1}\rightarrowΣ^{0}\barΣ^{0}) < 6.2\times 10^{-5}$, $\cal{B}$$(χ_{c2}\rightarrowΣ^{0}\barΣ^{0}) < 6.5\times 10^{-5}$, $\cal{B}$$(χ_{c1}\rightarrowΣ^{+}\barΣ^{-}) < 8.7\times 10^{-5}$ and $\cal{B}$$(χ_{c2}\rightarrowΣ^{+}\barΣ^{-}) < 8.8\times 10^{-5}$ at the 90% confidence level.
△ Less
Submitted 4 March, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.