-
Data quality control system and long-term performance monitor of the LHAASO-KM2A
Authors:
Zhen Cao,
F. Aharonian,
Axikegu,
Y. X. Bai,
Y. W. Bao,
D. Bastieri,
X. J. Bi,
Y. J. Bi,
W. Bian,
A. V. Bukevich,
Q. Cao,
W. Y. Cao,
Zhe Cao,
J. Chang,
J. F. Chang,
A. M. Chen,
E. S. Chen,
H. X. Chen,
Liang Chen,
Lin Chen,
Long Chen,
M. J. Chen,
M. L. Chen,
Q. H. Chen,
S. Chen
, et al. (263 additional authors not shown)
Abstract:
The KM2A is the largest sub-array of the Large High Altitude Air Shower Observatory (LHAASO). It consists of 5216 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs). The data recorded by the EDs and MDs are used to reconstruct primary information of cosmic ray and gamma-ray showers. This information is used for physical analysis in gamma-ray astronomy and cosmic ray physics. To…
▽ More
The KM2A is the largest sub-array of the Large High Altitude Air Shower Observatory (LHAASO). It consists of 5216 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs). The data recorded by the EDs and MDs are used to reconstruct primary information of cosmic ray and gamma-ray showers. This information is used for physical analysis in gamma-ray astronomy and cosmic ray physics. To ensure the reliability of the LHAASO-KM2A data, a three-level quality control system has been established. It is used to monitor the status of detector units, stability of reconstructed parameters and the performance of the array based on observations of the Crab Nebula and Moon shadow. This paper will introduce the control system and its application on the LHAASO-KM2A data collected from August 2021 to July 2023. During this period, the pointing and angular resolution of the array were stable. From the observations of the Moon shadow and Crab Nebula, the results achieved using the two methods are consistent with each other. According to the observation of the Crab Nebula at energies from 25 TeV to 100 TeV, the time averaged pointing errors are estimated to be $-0.003^{\circ} \pm 0.005^{\circ}$ and $0.001^{\circ} \pm 0.006^{\circ}$ in the R.A. and Dec directions, respectively.
△ Less
Submitted 13 June, 2024; v1 submitted 20 May, 2024;
originally announced May 2024.
-
Construction and On-site Performance of the LHAASO WFCTA Camera
Authors:
F. Aharonian,
Q. An,
Axikegu,
L. X. Bai,
Y. X. Bai,
Y. W. Bao,
D. Bastieri,
X. J. Bi,
Y. J. Bi,
H. Cai,
J. T. Cai,
Z. Cao,
Z. Cao,
J. Chang,
J. F. Chang,
X. C. Chang,
B. M. Chen,
J. Chen,
L. Chen,
L. Chen,
L. Chen,
M. J. Chen,
M. L. Chen,
Q. H. Chen,
S. H. Chen
, et al. (234 additional authors not shown)
Abstract:
The focal plane camera is the core component of the Wide Field-of-view Cherenkov/fluorescence Telescope Array (WFCTA) of the Large High-Altitude Air Shower Observatory (LHAASO). Because of the capability of working under moonlight without aging, silicon photomultipliers (SiPM) have been proven to be not only an alternative but also an improvement to conventional photomultiplier tubes (PMT) in this…
▽ More
The focal plane camera is the core component of the Wide Field-of-view Cherenkov/fluorescence Telescope Array (WFCTA) of the Large High-Altitude Air Shower Observatory (LHAASO). Because of the capability of working under moonlight without aging, silicon photomultipliers (SiPM) have been proven to be not only an alternative but also an improvement to conventional photomultiplier tubes (PMT) in this application. Eighteen SiPM-based cameras with square light funnels have been built for WFCTA. The telescopes have collected more than 100 million cosmic ray events and preliminary results indicate that these cameras are capable of working under moonlight. The characteristics of the light funnels and SiPMs pose challenges (e.g. dynamic range, dark count rate, assembly techniques). In this paper, we present the design features, manufacturing techniques and performances of these cameras. Finally, the test facilities, the test methods and results of SiPMs in the cameras are reported here.
△ Less
Submitted 4 July, 2021; v1 submitted 29 December, 2020;
originally announced December 2020.
-
Nuclear probes of an out-of-equilibrium plasma at the highest compression
Authors:
G. Zhang,
M. Huang,
A. Bonasera,
Y. G. Ma,
B. F. Shen,
H. W. Wang,
W. P. Wang,
J. C. Xu,
G. T. Fan,
H. J. Fu,
H. Xue,
H. Zheng,
L. X. Liu,
S. Zhang,
W. J. Li,
X. G. Cao,
X. G. Deng,
X. Y. Li,
Y. C. Liu,
Y. Yu,
Y. Zhang,
C. B. Fu,
X. P. Zhang
Abstract:
We report the highest compression reached in laboratory plasmas using eight laser beams, E$_{laser}$$\approx$12 kJ, $τ_{laser}$=2 ns in third harmonic on a CD$_2$ target at the ShenGuang-II Upgrade (SGII-Up) facility in Shanghai, China. We estimate the deuterium density $ρ_D$= 2.0 $\pm$ 0.9 kg/cm$^{3}$, and the average kinetic energy of the plasma ions less than 1 keV. The highest reached areal de…
▽ More
We report the highest compression reached in laboratory plasmas using eight laser beams, E$_{laser}$$\approx$12 kJ, $τ_{laser}$=2 ns in third harmonic on a CD$_2$ target at the ShenGuang-II Upgrade (SGII-Up) facility in Shanghai, China. We estimate the deuterium density $ρ_D$= 2.0 $\pm$ 0.9 kg/cm$^{3}$, and the average kinetic energy of the plasma ions less than 1 keV. The highest reached areal density $Λρ_{D}$=4.8 $\pm$ 1.5 g/cm$^{2}$ was obtained from the measured ratio of the sequential ternary fusion reactions (dd$\rightarrow$t+p and t+d$\rightarrow$$α$+n) and the two body reaction fusions (dd$\rightarrow$$^3$He+n). At such high densities, sequential ternary and also quaternary nuclear reactions become important as well (i.e. n(14.1 MeV) + $^{12}$C $\rightarrow$ n'+$^{12}$C* etc.) resulting in a shift of the neutron (and proton) kinetic energies from their birth values. The Down Scatter Ratio (DSR-quaternary nuclear reactions) method, i.e. the ratio of the 10-12MeV neutrons divided by the total number of 14.1MeV neutrons produced, confirms the high densities reported above. The estimated lifetime of the highly compressed plasma is 52 $\pm$ 9 ps, much smaller than the lasers pulse duration.
△ Less
Submitted 24 May, 2019; v1 submitted 13 November, 2018;
originally announced December 2018.
-
Electronics of Time-of-flight Measurement for Back-n at CSNS
Authors:
T. Yu,
P. Cao,
X. Y. Ji,
L. K. Xie,
X. R. Huang,
Q. An,
H. Y. Bai,
J. Bao,
Y. H. Chen,
P. J. Cheng,
Z. Q. Cui,
R. R. Fan,
C. Q. Feng,
M. H. Gu,
Z. J. Han,
G. Z. He,
Y. C. He,
Y. F. He,
H. X. Huang,
W. L. Huang,
X. L. Ji,
H. Y. Jiang,
W. Jiang,
H. Y. Jing,
L. Kang
, et al. (46 additional authors not shown)
Abstract:
Back-n is a white neutron experimental facility at China Spallation Neutron Source (CSNS). The time structure of the primary proton beam make it fully applicable to use TOF (time-of-flight) method for neutron energy measuring. We implement the electronics of TOF measurement on the general-purpose readout electronics designed for all of the seven detectors in Back-n. The electronics is based on PXI…
▽ More
Back-n is a white neutron experimental facility at China Spallation Neutron Source (CSNS). The time structure of the primary proton beam make it fully applicable to use TOF (time-of-flight) method for neutron energy measuring. We implement the electronics of TOF measurement on the general-purpose readout electronics designed for all of the seven detectors in Back-n. The electronics is based on PXIe (Peripheral Component Interconnect Express eXtensions for Instrumentation) platform, which is composed of FDM (Field Digitizer Modules), TCM (Trigger and Clock Module), and SCM (Signal Conditioning Module). T0 signal synchronous to the CSNS accelerator represents the neutron emission from the target. It is the start of time stamp. The trigger and clock module (TCM) receives, synchronizes and distributes the T0 signal to each FDM based on the PXIe backplane bus. Meantime, detector signals after being conditioned are fed into FDMs for waveform digitizing. First sample point of the signal is the stop of time stamp. According to the start, stop time stamp and the time of signal over threshold, the total TOF can be obtained. FPGA-based (Field Programmable Gate Array) TDC is implemented on TCM to accurately acquire the time interval between the asynchronous T0 signal and the global synchronous clock phase. There is also an FPGA-based TDC on FDM to accurately acquire the time interval between T0 arriving at FDM and the first sample point of the detector signal, the over threshold time of signal is obtained offline. This method for TOF measurement is efficient and not needed for additional modules. Test result shows the accuracy of TOF is sub-nanosecond and can meet the requirement for Back-n at CSNS.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
T0 Fan-out for Back-n White Neutron Facility at CSNS
Authors:
X. Y. Ji,
P. Cao,
T. Yu,
L. K. Xie,
X. R. Huang,
Q. An,
H. Y. Bai,
J. Bao,
Y. H. Chen,
P. J. Cheng,
Z. Q. Cui,
R. R. Fan,
C. Q. Feng,
M. H. Gu,
Z. J. Han,
G. Z. He,
Y. C. He,
Y. F. He,
H. X. Huang,
W. L. Huang,
X. L. Ji,
H. Y. Jiang,
W. Jiang,
H. Y. Jing,
L. Kang
, et al. (46 additional authors not shown)
Abstract:
the main physics goal for Back-n white neutron facility at China Spallation Neutron Source (CSNS) is to measure nuclear data. The energy of neutrons is one of the most important parameters for measuring nuclear data. Method of time of flight (TOF) is used to obtain the energy of neutrons. The time when proton bunches hit the thick tungsten target is considered as the start point of TOF. T0 signal,…
▽ More
the main physics goal for Back-n white neutron facility at China Spallation Neutron Source (CSNS) is to measure nuclear data. The energy of neutrons is one of the most important parameters for measuring nuclear data. Method of time of flight (TOF) is used to obtain the energy of neutrons. The time when proton bunches hit the thick tungsten target is considered as the start point of TOF. T0 signal, generated from the CSNS accelerator, represents this start time. Besides, the T0 signal is also used as the gate control signal that triggers the readout electronics. Obviously, the timing precision of T0 directly affects the measurement precision of TOF and controls the running or readout electronics. In this paper, the T0 fan-out for Back-n white neutron facility at CSNS is proposed. The T0 signal travelling from the CSNS accelerator is fanned out to the two underground experiment stations respectively over long cables. To guarantee the timing precision, T0 signal is conditioned with good signal edge. Furthermore, techniques of signal pre-emphasizing and equalizing are used to improve signal quality after T0 being transmitted over long cables with about 100 m length. Experiments show that the T0 fan-out works well, the T0 signal transmitted over 100 m remains a good time resolution with a standard deviation of 25 ps. It absolutely meets the required accuracy of the measurement of TOF.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.