-
Compact laser system with frequency stability dissemination for optical clocks and quantum computing
Authors:
M. I. Shakirov,
K. S. Kudeyarov,
N. O. Zhadnov,
D. S. Kryuchkov,
A. V. Tausenev,
K. Yu. Khabarova,
N. N. Kolachevsky
Abstract:
Modern experiments in quantum metrology, sensing, and quantum computing require precise control of the state of atoms and molecules, achieved through the use of highly stable lasers and microwave generators with low phase noise. One of the most effective methods for ensuring high frequency stability is stabilization using a high-finesse Fabry-Pérot reference cavity. However, implementing separate…
▽ More
Modern experiments in quantum metrology, sensing, and quantum computing require precise control of the state of atoms and molecules, achieved through the use of highly stable lasers and microwave generators with low phase noise. One of the most effective methods for ensuring high frequency stability is stabilization using a high-finesse Fabry-Pérot reference cavity. However, implementing separate stabilization systems for each laser increases the complexity and size of the setup, limiting its use to laboratory conditions. An alternative approach is the use of a femtosecond optical frequency comb, which transfers the noise characteristics of a single stabilized frequency reference to other wavelengths in the optical and microwave ranges. In this work, we demonstrate a scheme for transferring frequency stability from an ultrastable laser at 871 nm to a laser at 1550 nm. Measurements using the three-cornered hat method show that the stabilized laser exhibits a fractional frequency instability of less than 4e-15 for averaging times between 0.4 and 2 s, and below 1e-14 for intervals ranging from 0.2 to 500 s. The femtosecond optical frequency comb and the cavity-stabilized laser were designed to meet compactness and portability requirements to enable field and onboard applications.
△ Less
Submitted 15 April, 2025;
originally announced April 2025.
-
Optimized surface ion trap design for tight confinement and separation of ion chains
Authors:
Ilya Gerasin,
Nikita Zhadnov,
Konstantin Kudeyarov,
Ksienia Khabarova,
Nikolay Kolachevsky,
Ilya Semerikov
Abstract:
Qubit systems based on trapped ultracold ions win one of the leading positions in the quantum computing field, demonstrating quantum algorithms with the highest complexity to date. Surface Paul traps for ion confinement open the opportunity to scale quantum processors to hundreds of qubits and enable high-connectivity manipulations on ions. To fabricate such a system with certain characteristics,…
▽ More
Qubit systems based on trapped ultracold ions win one of the leading positions in the quantum computing field, demonstrating quantum algorithms with the highest complexity to date. Surface Paul traps for ion confinement open the opportunity to scale quantum processors to hundreds of qubits and enable high-connectivity manipulations on ions. To fabricate such a system with certain characteristics, the special design of a surface electrode structure is required. The depth of the trapping potential, the stability parameter, the secular frequency and the distance between an ion and the trap surface should be optimized for better performance. Here we present the optimized design of a relatively simple surface trap that allows several important high-fidelity primitives: tight ion confinement, laser cooling, and wide optical access. The suggested trap design also allows to perform an important basic operation, namely, splitting an ion chain into two parts.
△ Less
Submitted 19 July, 2024;
originally announced July 2024.
-
Pulsed CW laser for long-term spectroscopic measurements at high power in deep-UV
Authors:
Nikita Zhadnov,
Artem Golovizin,
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Paolo Crivelli
Abstract:
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while keeping t…
▽ More
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while keeping the average power low to prevent mirror degradation. Additionally, this method significantly decreases laser-induced background on charged particle detectors. The described 244 nm laser system is designed for 1S-2S two-photon CW spectroscopy of muonium in the Mu-MASS project. It was tested to provide intracavity powers above 20 W, requiring maintenance only a few times a day. The pulsing technique demonstrates minimal impact on the radiation frequency, with no observed shifts exceeding 15 kHz. Our approach represents a promising new technique for high-precision spectroscopy of atoms in harsh UV environments and demonstrates the feasibility of CW spectroscopy of muonium.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Update of Muonium 1S-2S transition frequency
Authors:
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Artem Golovizin,
Nikita Zhadnov,
Paolo Crivelli
Abstract:
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electr…
▽ More
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electron-to-muon mass ratio or, combined with the Muonium hyperfine splitting, an independent value of the Rydberg constant. Furthermore we report on the current status of the Mu-MASS experiment, which aims at measuring the Muonium 1S-2S transition frequency at a 10 kHz uncertainty level.
△ Less
Submitted 17 March, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
Temperature-independent optical cavities for laser frequency stabilization
Authors:
Nikita Zhadnov,
Anatoly Masalov
Abstract:
We propose a method for thermal expansion compensation of reference monolithic optical cavities for laser frequency stabilization. Two schemes of optical cavities are considered: a Fabry-Perot interferometer with a crimp ring and a whispering-gallery-mode cavity with a clamp. In each scheme, thermal expansion compensation is achieved due to the strained connection of the cavity with an element mad…
▽ More
We propose a method for thermal expansion compensation of reference monolithic optical cavities for laser frequency stabilization. Two schemes of optical cavities are considered: a Fabry-Perot interferometer with a crimp ring and a whispering-gallery-mode cavity with a clamp. In each scheme, thermal expansion compensation is achieved due to the strained connection of the cavity with an element made of a material with a high coefficient of thermal expansion. The temperature region of the cavities' optical length stabilization is estimated.
△ Less
Submitted 18 February, 2022;
originally announced February 2022.
-
Partial compensation of thermal noise in the fundamental mode of an optical cavity
Authors:
Nikita Zhadnov,
Nikolay Kolachevsky
Abstract:
Thermal noise of optical cavities limits the accuracy of many experiments on precision laser spectroscopy and interferometry. The study of the physical properties of this noise opens opportunities for the creation of more stable cavities, reduction of phase noise of optical radiation, and performance of accurate optical studies. The paper proposes a method of partial recording of TEM00 mode therma…
▽ More
Thermal noise of optical cavities limits the accuracy of many experiments on precision laser spectroscopy and interferometry. The study of the physical properties of this noise opens opportunities for the creation of more stable cavities, reduction of phase noise of optical radiation, and performance of accurate optical studies. The paper proposes a method of partial recording of TEM00 mode thermal noise of a Fabry-Perot cavity using two "probe" modes of higher order. The method allows partial compensation of noise in the fundamental mode. Mathematical modeling is performed, which confirms the efficiency of the method.
△ Less
Submitted 5 February, 2022;
originally announced February 2022.
-
Long 48-cm ULE cavities in vertical and horizontal orientations for Sr optical clock
Authors:
Nikita Zhadnov,
Konstantin Kudeyarov,
Denis Kryuchkov,
Gulnara Vishnyakova,
Ksenia Khabarova,
Nikolay Kolachevsky
Abstract:
The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidth. We present two ultrastable laser systems based on 48 cm long Fabry-Perot cavities made of ULE glass in horizontal and vertical configurations operating at 698 nm. Fractional frequency instability of the beat signal between two lasers reaches 1.6e-15 at the averaging time of 1 s. We…
▽ More
The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidth. We present two ultrastable laser systems based on 48 cm long Fabry-Perot cavities made of ULE glass in horizontal and vertical configurations operating at 698 nm. Fractional frequency instability of the beat signal between two lasers reaches 1.6e-15 at the averaging time of 1 s. We experimentally characterized the contribution of the different noise sources (power fluctuations, residual amplitude modulation, the Doppler noise, sensitivity to the shock impact) and found that in our case the laser frequency instability to a large extent is determined by an optoelectronic feedback loop. Although the vertical configuration proved to be easier to manufacture and to transport, it turned out that it is much more sensitive to acoustics and horizontal accelerations compared to the horizontal one. Both laser systems were transported over a 60 km distance from the Lebedev Physical Institute to the Russian National Metrology Institute (VNIIFTRI) where they serve as local oscillators for spectroscopy of the clock transition in the recently developed strontium optical clock.
△ Less
Submitted 3 June, 2021;
originally announced June 2021.