Skip to main content

Showing 1–9 of 9 results for author: Zegers, R

Searching in archive physics. Search in all archives.
.
  1. arXiv:2411.03338  [pdf, other

    physics.ins-det nucl-ex

    Machine-Learning-Enabled Measurements of Astrophysical (p,n) Reactions with the SECAR Recoil Separator

    Authors: P. Tsintari, N. Dimitrakopoulos, R. Garg, K. Hermansen, C. Marshall, F. Montes, G. Perdikakis, H. Schatz, K. Setoodehnia, H. Arora, G. P. A. Berg, R. Bhandari, J. C. Blackmon, C. R. Brune, K. A. Chipps, M. Couder, C. Deibel, A. Hood, M. Horana Gamage, R. Jain, C. Maher, S. Miskovitch, J. Pereira, T. Ruland, M. S. Smith , et al. (7 additional authors not shown)

    Abstract: The synthesis of heavy elements in supernovae is affected by low-energy (n,p) and (p,n) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a nove… ▽ More

    Submitted 19 December, 2024; v1 submitted 31 October, 2024; originally announced November 2024.

  2. arXiv:2207.05995  [pdf, other

    physics.ins-det nucl-ex

    Design of the High Rigidity Spectrometer at FRIB

    Authors: S. Noji, R. G. T. Zegers, G. P. A. Berg, A. M. Amthor, T. Baumann, D. Bazin, E. E. Burkhardt, M. Cortesi, J. C. DeKamp, M. Hausmann, M. Portillo, D. H. Potterveld, B. M. Sherrill, A. Stolz, O. B. Tarasov, R. C. York

    Abstract: A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies ($\gtrsim$100MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper ca… ▽ More

    Submitted 19 October, 2022; v1 submitted 13 July, 2022; originally announced July 2022.

    Comments: 24 pages, 26 figures, 6 tables

    Journal ref: Nucl. Instrum. Methods Phys. Res., Sect. A 1045 (2023) 167548

  3. arXiv:2110.04329  [pdf, other

    physics.ed-ph

    Rubric-based holistic review: a promising route to equitable graduate admissions in physics

    Authors: Nicholas T. Young, K. Tollefson, Remco G. T. Zegers, Marcos D. Caballero

    Abstract: As systematic inequities in higher education and society have been brought to the forefront, graduate programs are interested in increasing the diversity of their applicants and enrollees. Yet, structures in place to evaluate applicants may not support such aims. One potential solution to support those aims is rubric-based holistic review. Starting in 2018, our physics department implemented a rub… ▽ More

    Submitted 8 October, 2021; originally announced October 2021.

    Comments: 21 pages, 8 figures

  4. arXiv:2004.13506  [pdf, other

    physics.ins-det nucl-ex

    A technique for the study of (p,n) reactions with unstable isotopes at energies relevant to astrophysics

    Authors: P. Gastis, G. Perdikakis, G. P. A. Berg, A. C. Dombos, A. Estrade, A. Falduto, M. Horoi, S. N. Liddick, S. Lipschutz, S. Lyons, F. Montes, A. Palmisano, J. Pereira, J. S. Randhawa, T. Redpath, M. Redshaw, J. Schmitt, J. R. Sheehan, M. K. Smith, P. Tsintari, A. C. C. Villari, K. Wang, R. G. T. Zegers

    Abstract: We have developed and tested an experimental technique for the measurement of low-energy (p,n) reactions in inverse kinematics relevant to nuclear astrophysics. The proposed setup is located at the ReA3 facility at the National Superconducting Cyclotron Laboratory. In the current approach, we operate the beam-transport line in ReA3 as a recoil separator while tagging the outgoing neutrons from the… ▽ More

    Submitted 16 July, 2020; v1 submitted 27 April, 2020; originally announced April 2020.

    Comments: Submitted to NIMA. Revised manuscript after referees' first review

  5. arXiv:1912.04273  [pdf

    physics.ins-det hep-ex nucl-ex

    Development of a novel MPGD-based drift chamber for the NSCL/FRIB S800 spectrometer

    Authors: M. Cortesi, J. Pereira, D. Bazin, Y. Ayyad, G. Cerizza, R. Fox, R. G. T. Zegers

    Abstract: The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The… ▽ More

    Submitted 7 December, 2019; originally announced December 2019.

    Comments: 13 pages, 13 figures

  6. arXiv:1601.04579  [pdf, other

    physics.ins-det nucl-ex

    Digital Data Acquisition For the Low Energy Neutron Detector Array (LENDA)

    Authors: S. Lipschutz, R. G. T. Zegers, J. Hill, S. N. Liddick, S. Noji, C. J. Prokop, M. Scott, M. Solt, C. Sullivan, J. Tompkins

    Abstract: A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV to 10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibili… ▽ More

    Submitted 19 January, 2016; v1 submitted 18 January, 2016; originally announced January 2016.

    Comments: Typo fixed in Abstract

  7. arXiv:1511.05289  [pdf, other

    cond-mat.quant-gas gr-qc nlin.PS physics.flu-dyn

    No hair theorems for analogue black holes

    Authors: Florent Michel, Renaud Parentani, Robin Zegers

    Abstract: We show that transonic one dimensional flows which are analogous to black holes obey no-hair theorems both at the level of linear perturbations and in non-linear regimes. Considering solutions of the Gross-Pitaevskii (or Korteweg-de Vries) equation, we show that stationary flows which are asymptotically uniform on both sides of the horizon are stable and act as attractors. Using Whitham's modulati… ▽ More

    Submitted 11 April, 2016; v1 submitted 17 November, 2015; originally announced November 2015.

    Comments: Final version published in PRD; a new figure illustrates the link with the relativistic regime, and another the stability of the results when considering larger non-linear perturbations; a few typos fixed

    Report number: LPT-Orsay-15-86

    Journal ref: Phys. Rev. D 93, 065039 (2016)

  8. arXiv:1111.4011  [pdf, other

    nucl-ex physics.ins-det

    LENDA, a Low Energy Neutron Detector Array for experiments with radioactive beams in inverse kinematics

    Authors: G. Perdikakis, M. Sasano, Sam M. Austin, D. Bazin, C. Caesar, S. Cannon, J. M. Deaven, H. J. Doster, C. J. Guess, G. W. Hitt, J. Marks, R. Meharchand, D. T. Nguyen, D. Peterman, A. Prinke, M. Scott, Y. Shimbara, K. Thorne, L. Valdez, R. G. T. Zegers

    Abstract: The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p, n) charge-exchange reactions at intermediate energies (> 100 M… ▽ More

    Submitted 21 May, 2012; v1 submitted 16 November, 2011; originally announced November 2011.

    Comments: Version accepted for publication in Nucl. Instr. Methods A. Revised text, 2 new figures added (one in section 4 and one in section 7)

  9. arXiv:physics/0702246  [pdf, ps, other

    physics.ins-det physics.space-ph

    A Pair Polarimeter for Linearly Polarized High Energy Photons

    Authors: C. deJager, B. Wojtsekhowski, D. Tedeschi, B. Vlahovic, D. Abbott, J. Asai, G. Feldman, T. Hotta, M. Khadaker, H. Kohri, T. Matsumara, T. Mibe, T. Nakano, V. Nelyubin, G. Orielly, A. Rudge, P. Weilhammer, M. Wood, T. Yorita, R. Zegers

    Abstract: A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing power of 20% and an efficiency of 0.02%. The layout and first results of a polarimeter test on the laser back-scattering photon beam at SPring-8/LEPS are presen… ▽ More

    Submitted 27 February, 2007; originally announced February 2007.

    Report number: JLAB-PHY-03-162

    Journal ref: Eur.Phys.J.A19:S275-S278,2004