-
Machine-Learning-Enabled Measurements of Astrophysical (p,n) Reactions with the SECAR Recoil Separator
Authors:
P. Tsintari,
N. Dimitrakopoulos,
R. Garg,
K. Hermansen,
C. Marshall,
F. Montes,
G. Perdikakis,
H. Schatz,
K. Setoodehnia,
H. Arora,
G. P. A. Berg,
R. Bhandari,
J. C. Blackmon,
C. R. Brune,
K. A. Chipps,
M. Couder,
C. Deibel,
A. Hood,
M. Horana Gamage,
R. Jain,
C. Maher,
S. Miskovitch,
J. Pereira,
T. Ruland,
M. S. Smith
, et al. (7 additional authors not shown)
Abstract:
The synthesis of heavy elements in supernovae is affected by low-energy (n,p) and (p,n) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a nove…
▽ More
The synthesis of heavy elements in supernovae is affected by low-energy (n,p) and (p,n) reactions on unstable nuclei, yet experimental data on such reaction rates are scarce. The SECAR (SEparator for CApture Reactions) recoil separator at FRIB (Facility for Rare Isotope Beams) was originally designed to measure astrophysical reactions that change the mass of a nucleus significantly. We used a novel approach that integrates machine learning with ion-optical simulations to find an ion-optical solution for the separator that enables the measurement of (p,n) reactions, despite the reaction leaving the mass of the nucleus nearly unchanged. A new measurement of the $^{58}$Fe(p,n)$^{58}$Co reaction in inverse kinematics with a 3.66$\pm$0.12 MeV/nucleon $^{58}$Fe beam (corresponding to 3.69$\pm$0.12 MeV proton energy in normal kinematics) yielded a cross-section of 20.3$\pm$6.3 mb and served as a benchmark for the new technique demonstrating its effectiveness in achieving the required performance criteria. This novel approach marks a significant advancement in experimental nuclear astrophysics, as it paves the way for studying astrophysically important (p,n) reactions on unstable nuclei produced at FRIB.
△ Less
Submitted 19 December, 2024; v1 submitted 31 October, 2024;
originally announced November 2024.
-
Design of the High Rigidity Spectrometer at FRIB
Authors:
S. Noji,
R. G. T. Zegers,
G. P. A. Berg,
A. M. Amthor,
T. Baumann,
D. Bazin,
E. E. Burkhardt,
M. Cortesi,
J. C. DeKamp,
M. Hausmann,
M. Portillo,
D. H. Potterveld,
B. M. Sherrill,
A. Stolz,
O. B. Tarasov,
R. C. York
Abstract:
A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies ($\gtrsim$100MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper ca…
▽ More
A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies ($\gtrsim$100MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. The maximum magnetic rigidity of the HRS is 8Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.
△ Less
Submitted 19 October, 2022; v1 submitted 13 July, 2022;
originally announced July 2022.
-
Rubric-based holistic review: a promising route to equitable graduate admissions in physics
Authors:
Nicholas T. Young,
K. Tollefson,
Remco G. T. Zegers,
Marcos D. Caballero
Abstract:
As systematic inequities in higher education and society have been brought to the forefront, graduate programs are interested in increasing the diversity of their applicants and enrollees. Yet, structures in place to evaluate applicants may not support such aims. One potential solution to support those aims is rubric-based holistic review. Starting in 2018, our physics department implemented a rub…
▽ More
As systematic inequities in higher education and society have been brought to the forefront, graduate programs are interested in increasing the diversity of their applicants and enrollees. Yet, structures in place to evaluate applicants may not support such aims. One potential solution to support those aims is rubric-based holistic review. Starting in 2018, our physics department implemented a rubric-based holistic review process for all applicants to our graduate program. The rubric assessed applicants on 18 metrics covering their grades, test scores, research experiences, noncognitive competencies, and fit with the program. We then compared faculty's ratings of applicants by admission status, sex, and undergraduate program over a three-year period. We find that the rubric scores show statistically significant differences between admitted and non-admitted students as hoped and that statistically significant differences based on sex or undergraduate program aligned with known disparities in GRE scores and service work expectations. Our results then suggest rubric-based holistic review as a possible route to making graduate admissions in physics more equitable.
△ Less
Submitted 8 October, 2021;
originally announced October 2021.
-
A technique for the study of (p,n) reactions with unstable isotopes at energies relevant to astrophysics
Authors:
P. Gastis,
G. Perdikakis,
G. P. A. Berg,
A. C. Dombos,
A. Estrade,
A. Falduto,
M. Horoi,
S. N. Liddick,
S. Lipschutz,
S. Lyons,
F. Montes,
A. Palmisano,
J. Pereira,
J. S. Randhawa,
T. Redpath,
M. Redshaw,
J. Schmitt,
J. R. Sheehan,
M. K. Smith,
P. Tsintari,
A. C. C. Villari,
K. Wang,
R. G. T. Zegers
Abstract:
We have developed and tested an experimental technique for the measurement of low-energy (p,n) reactions in inverse kinematics relevant to nuclear astrophysics. The proposed setup is located at the ReA3 facility at the National Superconducting Cyclotron Laboratory. In the current approach, we operate the beam-transport line in ReA3 as a recoil separator while tagging the outgoing neutrons from the…
▽ More
We have developed and tested an experimental technique for the measurement of low-energy (p,n) reactions in inverse kinematics relevant to nuclear astrophysics. The proposed setup is located at the ReA3 facility at the National Superconducting Cyclotron Laboratory. In the current approach, we operate the beam-transport line in ReA3 as a recoil separator while tagging the outgoing neutrons from the (p,n) reactions with the low-energy neutron detector array (LENDA). The developed technique was verified by using the $^{40}$Ar(p,n)$^{40}$K reaction as a probe. The results of the proof-of-principle experiment with the $^{40}$Ar beam show that cross-section measurements within an uncertainty of $\sim$25\% are feasible with count rates up to 7 counts/mb/pnA/s. In this article, we give a detailed description of the experimental setup, and present the analysis method and results from the test experiment. Future plans on using the technique in experiments with the separator for capture reactions (SECAR) that is currently being commissioned are also discussed.
△ Less
Submitted 16 July, 2020; v1 submitted 27 April, 2020;
originally announced April 2020.
-
Development of a novel MPGD-based drift chamber for the NSCL/FRIB S800 spectrometer
Authors:
M. Cortesi,
J. Pereira,
D. Bazin,
Y. Ayyad,
G. Cerizza,
R. Fox,
R. G. T. Zegers
Abstract:
The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The…
▽ More
The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The signals from the Micromegas readout are processed by a data acquisition system based on the General Electronics for TPC (GET). The drift chamber has an effective area of around 60x30 cm^2, which matches to the very large acceptance of the S800 spectrometer. This work discusses in detail the results of performance evaluation tests carried out with a low-energy alpha-particles source and with high-energy heavy-ion beams with the detector installed at the S800 focal plane. In this latter case, the detector was irradiated with a 150 MeV/u 78Kr36+ beam as well as a heavy-ion fragmentation cocktail beam produced by the 78Kr36+ beam impinging on a thin beryllium target. Sub-millimeter position resolution is obtained in both dispersive and non-dispersive directions.
△ Less
Submitted 7 December, 2019;
originally announced December 2019.
-
Digital Data Acquisition For the Low Energy Neutron Detector Array (LENDA)
Authors:
S. Lipschutz,
R. G. T. Zegers,
J. Hill,
S. N. Liddick,
S. Noji,
C. J. Prokop,
M. Scott,
M. Solt,
C. Sullivan,
J. Tompkins
Abstract:
A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV to 10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibili…
▽ More
A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV to 10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibility to lower the neutron detection threshold, increase the overall neutron-detection efficiency, decrease the dead time of the system, and allow for easy expansion of the array. The system utilized in this work was XIA's Digital Gamma Finder Pixie-16 250 MHz digitizers. A detector-limited timing resolution of 400 ps was achieved for a single LENDA bar. Using DDAS, the neutron detection threshold of the system was reduced compared to the previous analog system, now reaching below 100 keV. The new DAQ system was successfully used in a recent charge-exchange experiment using the $^{16}$C(p,n) reaction at the National Superconducting Cyclotron Laboratory (NSCL).
△ Less
Submitted 19 January, 2016; v1 submitted 18 January, 2016;
originally announced January 2016.
-
No hair theorems for analogue black holes
Authors:
Florent Michel,
Renaud Parentani,
Robin Zegers
Abstract:
We show that transonic one dimensional flows which are analogous to black holes obey no-hair theorems both at the level of linear perturbations and in non-linear regimes. Considering solutions of the Gross-Pitaevskii (or Korteweg-de Vries) equation, we show that stationary flows which are asymptotically uniform on both sides of the horizon are stable and act as attractors. Using Whitham's modulati…
▽ More
We show that transonic one dimensional flows which are analogous to black holes obey no-hair theorems both at the level of linear perturbations and in non-linear regimes. Considering solutions of the Gross-Pitaevskii (or Korteweg-de Vries) equation, we show that stationary flows which are asymptotically uniform on both sides of the horizon are stable and act as attractors. Using Whitham's modulation theory, we analytically characterize the emitted waves when starting from uniform perturbations. Numerical simulations confirm the validity of this approximation and extend the results to more general perturbations and to the (non-integrable) cubic-quintic Gross-Pitaevskii equation. When considering time reversed flows that correspond to white holes, the asymptotically uniform flows are unstable to sufficiently large perturbations and emit either a macroscopic undulation in the supersonic side, or a non-linear superposition of soliton trains.
△ Less
Submitted 11 April, 2016; v1 submitted 17 November, 2015;
originally announced November 2015.
-
LENDA, a Low Energy Neutron Detector Array for experiments with radioactive beams in inverse kinematics
Authors:
G. Perdikakis,
M. Sasano,
Sam M. Austin,
D. Bazin,
C. Caesar,
S. Cannon,
J. M. Deaven,
H. J. Doster,
C. J. Guess,
G. W. Hitt,
J. Marks,
R. Meharchand,
D. T. Nguyen,
D. Peterman,
A. Prinke,
M. Scott,
Y. Shimbara,
K. Thorne,
L. Valdez,
R. G. T. Zegers
Abstract:
The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p, n) charge-exchange reactions at intermediate energies (> 100 M…
▽ More
The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p, n) charge-exchange reactions at intermediate energies (> 100 MeV/u). It can be used, however, for any reaction study that involves emission of low energy neutrons (150 keV - 10 MeV). The array consists of 24 plastic scintillator bars and is capable of registering the recoiling neutron energy and angle with high detection efficiency. The neutron energy is determined by the time-of-flight technique, while the position of interaction is deduced using the timing and energy information from the two photomultipliers of each bar. A simple test setup utilizing radioactive sources has been used to characterize the array. Results of test measurements are compared with simulations. A neutron energy threshold of < 150 keV, an intrinsic time (position) resolution of \sim 400 ps (\sim 6 cm) and an efficiency > 20 % for neutrons below 4 MeV have been obtained.
△ Less
Submitted 21 May, 2012; v1 submitted 16 November, 2011;
originally announced November 2011.
-
A Pair Polarimeter for Linearly Polarized High Energy Photons
Authors:
C. deJager,
B. Wojtsekhowski,
D. Tedeschi,
B. Vlahovic,
D. Abbott,
J. Asai,
G. Feldman,
T. Hotta,
M. Khadaker,
H. Kohri,
T. Matsumara,
T. Mibe,
T. Nakano,
V. Nelyubin,
G. Orielly,
A. Rudge,
P. Weilhammer,
M. Wood,
T. Yorita,
R. Zegers
Abstract:
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing power of 20% and an efficiency of 0.02%. The layout and first results of a polarimeter test on the laser back-scattering photon beam at SPring-8/LEPS are presen…
▽ More
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing power of 20% and an efficiency of 0.02%. The layout and first results of a polarimeter test on the laser back-scattering photon beam at SPring-8/LEPS are presented.
△ Less
Submitted 27 February, 2007;
originally announced February 2007.