-
Single-exposure X-ray dark-field imaging via a dual-energy propagation-based setup
Authors:
Jannis N. Ahlers,
Konstantin M. Pavlov,
Marcus J. Kitchen,
Stephanie A. Harker,
Emily J. Pryor,
James A. Pollock,
Michelle K. Croughan,
Ying Ying How,
Marie-Christine Zdora,
Lucy F. Costello,
Dylan W. O'Connell,
Christopher Hall,
Kaye S. Morgan
Abstract:
X-ray dark-field imaging visualises scattering from sample microstructure, and has found application in medical and security contexts. While most X-ray dark-field imaging techniques rely on masks, gratings, or crystals, recent work on the Fokker--Planck model of diffusive imaging has enabled dark-field imaging in the propagation-based geometry. Images captured at multiple propagation distances or…
▽ More
X-ray dark-field imaging visualises scattering from sample microstructure, and has found application in medical and security contexts. While most X-ray dark-field imaging techniques rely on masks, gratings, or crystals, recent work on the Fokker--Planck model of diffusive imaging has enabled dark-field imaging in the propagation-based geometry. Images captured at multiple propagation distances or X-ray energies can be used to reconstruct dark-field from propagation-based images but have previously required multiple exposures. Here, we show single-exposure dark-field imaging by exploiting the harmonic content in a monochromatised synchrotron beam and utilising an energy-discriminating photon-counting detector to capture dual-energy propagation-based images. The method is validated by filming time-varying samples, showing the advantage of the dark-field contrast in analysing dynamic evolution. We measure and adjust for the impact of detector charge-sharing on the images. This work opens the way for low-dose and dynamic dark-field X-ray imaging without the need for a high-stability set-up and precision optics.
△ Less
Submitted 17 December, 2024;
originally announced December 2024.
-
Robust dark-field signal extraction for modulation-based X-ray tensor tomography
Authors:
Ginevra Lautizi,
Vittorio Di Trapani,
Alain Studer,
Marie-Christine Zdora,
Fabio De Marco,
Jisoo Kim,
Federica Marone,
Marco Stampanoni,
Pierre Thibault
Abstract:
We demonstrate a robust signal extraction method for X-ray speckle-based tensor tomography. We validate the effectiveness of the method for several carbon fiber composites, highlighting its potential for industrial applications. The proposed method can be adapted to various acquisition schemes and wavefront-marking optical elements, making it a versatile and robust tool for X-ray scattering tensor…
▽ More
We demonstrate a robust signal extraction method for X-ray speckle-based tensor tomography. We validate the effectiveness of the method for several carbon fiber composites, highlighting its potential for industrial applications. The proposed method can be adapted to various acquisition schemes and wavefront-marking optical elements, making it a versatile and robust tool for X-ray scattering tensor tomography.
△ Less
Submitted 27 November, 2024;
originally announced November 2024.
-
A universal reconstruction method for X ray scattering tensor tomography based on wavefront modulation
Authors:
Ginevra Lautizi,
Alain Studer,
Marie-Christine Zdora,
Fabio De Marco,
Jisoo Kim,
Vittorio Di Trapani,
Federica Marone,
Pierre Thibault,
Marco Stampanoni
Abstract:
We present a versatile method for full-field, X-ray scattering tensor tomography that is based on energy conservation and is applicable to data obtained using different wavefront modulators. Using this algorithm, we pave the way for speckle-based tensor tomography. The proposed model relies on a mathematical approach that allows tuning spatial resolution and signal sensitivity. We present the appl…
▽ More
We present a versatile method for full-field, X-ray scattering tensor tomography that is based on energy conservation and is applicable to data obtained using different wavefront modulators. Using this algorithm, we pave the way for speckle-based tensor tomography. The proposed model relies on a mathematical approach that allows tuning spatial resolution and signal sensitivity. We present the application of the algorithm to three different imaging modalities and demonstrate its potential for applications of X-ray directional dark-field imaging.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
Refraction beats attenuation in breast CT
Authors:
Michał Rawlik,
Alexandre Pereira,
Simon Spindler,
Zhentian Wang,
Lucia Romano,
Konstantins Jefimovs,
Zhitian Shi,
Maxim Polikarpov,
Jinqiu Xu,
Marie-Christine Zdora,
Stefano van Gogh,
Martin Stauber,
Eduardo Yukihara,
Jeppe Brage Christensen,
Rahel Kubik-Huch,
Tilo Niemann,
Cornelia Leo,
Zsuzsanna Varga,
Andreas Boss,
Marco Stampanoni
Abstract:
For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grat…
▽ More
For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grating interferometry (GI) could eventually allow computed tomography (CT) to be more dose-efficient. However, the benefit of refraction in clinical CT has not been demonstrated so far. Here we show that GI-CT is more dose-efficient in imaging of breast tissue than conventional CT. Our system, based on a 70kVp X-ray tube source and commercially available gratings, demonstrated superior quality, in terms of adipose-to-glandular tissue contrast-to-noise ratio (CNR), of refraction-contrast compared to the attenuation images. The fusion of the two modes of contrast outperformed conventional CT for spatial resolutions better than 263μm and an average dose to the breast of 16mGy, which is in the clinical breast CT range. Our results show that grating interferometry can significantly reduce the dose, while maintaining the image quality, in diagnostic breast CT. Unlike conventional absorption-based CT, the sensitivity of refraction-based imaging is far from being fully exploited, and further progress will lead to significant improvements of clinical X-ray CT.
△ Less
Submitted 1 January, 2023;
originally announced January 2023.
-
Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources
Authors:
Patrik Vagovič,
Tokushi Sato,
Ladislav Mikeš,
Grant Mills,
Rita Graceffa,
Frans Mattsson,
Pablo Villanueva-Perez,
Alexey Ershov,
Tomáš Faragó,
Jozef Uličný,
Henry Kirkwood,
Romain Letrun,
Rajmund Mokso,
Marie-Christine Zdora,
Margie P. Olbinado,
Alexander Rack,
Tilo Baumbach,
Alke Meents,
Henry N. Chapman,
Adrian P. Mancuso
Abstract:
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glas…
▽ More
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.