-
Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. Ataee Langroudy,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen,
R. Chen,
N. Chott,
J. Cooley
, et al. (124 additional authors not shown)
Abstract:
We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used…
▽ More
We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.
△ Less
Submitted 3 September, 2025;
originally announced September 2025.
-
Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso-Gonzalez,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. Ataee Langroudy,
C. Bathurst,
R. Bhattacharyya,
A. J. Biff,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
J. H. Chen,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (117 additional authors not shown)
Abstract:
SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their r…
▽ More
SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.
△ Less
Submitted 27 August, 2025;
originally announced August 2025.
-
Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-Gonźalez,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. Ataee Langroudy,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen,
R. Chen,
N. Chott
, et al. (126 additional authors not shown)
Abstract:
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a succes…
▽ More
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.
△ Less
Submitted 4 August, 2025;
originally announced August 2025.
-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (117 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 5 September, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches
Authors:
M. J. Wilson,
A. Zaytsev,
B. von Krosigk,
I. Alkhatib,
M. Buchanan,
R. Chen,
M. D. Diamond,
E. Figueroa-Feliciano,
S. A. S. Harms,
Z. Hong,
K. T. Kennard,
N. A. Kurinsky,
R. Mahapatra,
N. Mirabolfathi,
V. Novati,
M. Platt,
R. Ren,
A. Sattari,
B. Schmidt,
Y. Wang,
S. Zatschler,
E. Zhang,
A. Zuniga
Abstract:
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number…
▽ More
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.
△ Less
Submitted 24 June, 2024; v1 submitted 2 March, 2024;
originally announced March 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Suppression of alpha-induced lateral surface events in the COBRA experiment using CdZnTe detectors with an instrumented guard-ring electrode
Authors:
J. -H. Arling,
M. Gerhardt,
C. Gößling,
D. Gehre,
R. Klingenberg,
K. Kröninger,
C. Nitsch,
T. Quante,
K. Rohatsch,
J. Tebrügge,
R. Temminghoff,
R. Theinert,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration searches for neutrinoless double beta-decay ($0νββ$-decay) using CdZnTe semiconductor detectors with a coplanar-grid readout and a surrounding guard-ring structure. The operation of the COBRA demonstrator at the Gran Sasso underground laboratory (LNGS) indicates that alpha-induced lateral surface events are the dominant source of background events. By instrumenting the guar…
▽ More
The COBRA collaboration searches for neutrinoless double beta-decay ($0νββ$-decay) using CdZnTe semiconductor detectors with a coplanar-grid readout and a surrounding guard-ring structure. The operation of the COBRA demonstrator at the Gran Sasso underground laboratory (LNGS) indicates that alpha-induced lateral surface events are the dominant source of background events. By instrumenting the guard-ring electrode it is possible to suppress this type of background. In laboratory measurements this method achieved a suppression factor of alpha-induced lateral surface events of $5300^{+2660}_{-1380}$, while retaining $85.3\pm0.1\%$ of gamma events occurring in the entire detector volume. This suppression is superior to the pulse-shape analysis methods used so far in COBRA by three orders of magnitude.
△ Less
Submitted 12 December, 2017; v1 submitted 25 January, 2017;
originally announced January 2017.
-
Results of a search for neutrinoless double-beta decay using the COBRA demonstrator
Authors:
Joachim Ebert,
Matthew Fritts,
Daniel Gehre,
Claus Goessling,
Caren Hagner,
Nadine Heidrich,
Reiner Klingenberg,
Kevin Kroeninger,
Christian Nitsch,
Christian Oldorf,
Thomas Quante,
Silke Rajek,
Henning Rebber,
Katja Rohatsch,
Jan Tebruegge,
Robert Temminghoff,
Robert Theinert,
Jan Timm,
Bjoern Wonsak,
Stefan Zatschler,
Kai Zuber
Abstract:
Neutrinoless double-$β$ decay ($0νββ$ decay) is a hypothetical process that can occur if the neutrino is its own antiparticle. The COBRA collaboration operates a demonstrator to search for these decays at the Laboratori Nazionali del Gran Sasso in Italy using CdZnTe semiconductor detectors. The exposure of $234.7\,$kg\,d considered in this analysis was collected between September 2011 and February…
▽ More
Neutrinoless double-$β$ decay ($0νββ$ decay) is a hypothetical process that can occur if the neutrino is its own antiparticle. The COBRA collaboration operates a demonstrator to search for these decays at the Laboratori Nazionali del Gran Sasso in Italy using CdZnTe semiconductor detectors. The exposure of $234.7\,$kg\,d considered in this analysis was collected between September 2011 and February 2015. The analysis focuses on the decay of the nuclides $^{114}$Cd, $^{128}$Te, $^{70}$Zn, $^{130}$Te and $^{116}$Cd. A Bayesian analysis is performed to estimate the signal strength of $0νββ$ decay. No signal is observed for any of these nuclides. Therefore, the following half-life limits at 90% credibility are set: $T_{1/2}^{0ν}>1.6\cdot10^{21}\,$yr ($^{114}$Cd), $T_{1/2}^{0ν}>1.9\cdot10^{21}\,$yr ($^{128}Te$), $T_{1/2}^{0ν}>6.8\cdot10^{18}\,$yr ($^{70}$Zn), $T_{1/2}^{0ν}>6.1\cdot10^{21}\,$yr ($^{130}$Te), and $T_{1/2}^{0ν}>1.1\cdot10^{21}\,$yr ($^{116}$Cd).
△ Less
Submitted 29 November, 2016; v1 submitted 14 September, 2015;
originally announced September 2015.
-
Characterization of a large CdZnTe coplanar quad-grid semiconductor detector
Authors:
J. Ebert,
D. Gehre,
C. Gößling,
C. Hagner,
N. Heidrich,
R. Klingenberg,
K. Kröninger,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
K. Rohatsch,
J. Tebrügge,
R. Temminghoff,
R. Theinert,
J. Timm,
B. Wonsak,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration aims to search for neutrinoless double beta-decay of $^{116}$Cd. A demonstrator setup with 64 CdZnTe semiconductor detectors, each with a volume of 1cm$^3$, is currently being operated at the LNGS underground laboratory in Italy. This paper reports on the characterization of a large (2 $\times$ 2 $\times$ 1.5)cm$^3$ CdZnTe detector with a new coplanar-grid design for applic…
▽ More
The COBRA collaboration aims to search for neutrinoless double beta-decay of $^{116}$Cd. A demonstrator setup with 64 CdZnTe semiconductor detectors, each with a volume of 1cm$^3$, is currently being operated at the LNGS underground laboratory in Italy. This paper reports on the characterization of a large (2 $\times$ 2 $\times$ 1.5)cm$^3$ CdZnTe detector with a new coplanar-grid design for applications in $γ$-ray spectroscopy and low-background operation. Several studies of electric properties as well as of the spectrometric performance, like energy response and resolution, are conducted. Furthermore, measurements including investigating the operational stability and a possibility to identify multiple-scattered photons are presented.
△ Less
Submitted 11 February, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Long-Term Stability of Underground Operated CZT Detectors Based on the Analysis of Intrinsic $^{113}$Cd β$^{-}$-Decay
Authors:
J. Ebert,
C. Goessling,
D. Gehre,
C. Hagner,
N. Heidrich,
R. Klingenberg,
K. Kroeninger,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
K. Rohatsch,
J. Tebruegge,
R. Temminghoff,
R. Theinert,
J. Timm,
B. Wonsak,
S. Zatschler,
K. Zuber
Abstract:
The COBRA collaboration operates a demonstrator setup at the underground facility LNGS (Laboratori Nazionali del Gran Sasso, located in Italy) to prove the technological capabilities of this concept for the search for neutrinoless double beta-decay. The setup consists of 64 $(1\times\!1\times\!1)$ cm$^{3}$ CZT detectors in CPG configuration. One purpose of this demonstrator is to test if reliable…
▽ More
The COBRA collaboration operates a demonstrator setup at the underground facility LNGS (Laboratori Nazionali del Gran Sasso, located in Italy) to prove the technological capabilities of this concept for the search for neutrinoless double beta-decay. The setup consists of 64 $(1\times\!1\times\!1)$ cm$^{3}$ CZT detectors in CPG configuration. One purpose of this demonstrator is to test if reliable long-term operation of CZT-CPG detectors in such a setup is possible. The demonstrator has been operated under ultra low-background conditions since more than three years and collected data corresponding to an exposure of 218 kg$\cdot$days. The presented study focuses on the long-term stability of CZT detectors by analyzing the intrinsic, fourfold forbidden non-unique $^{113}$Cd single beta-decay. It can be shown that CZT detectors can be operated stably for long periods of time and that the $^{113}$Cd single beta-decay can be used as an internal monitor of the detector performance during the runtime of the experiment.
△ Less
Submitted 13 August, 2015;
originally announced August 2015.
-
The COBRA demonstrator at the LNGS underground laboratory
Authors:
The COBRA collaboration,
J. Ebert,
M. Fritts,
D. Gehre,
C. Gößling,
T. Göpfert,
C. Hagner,
N. Heidrich,
R. Klingenberg,
T. Köttig,
K. Kröninger,
T. Michel,
T. Neddermann,
C. Nitsch,
C. Oldorf,
T. Quante,
S. Rajek,
H. Rebber,
O. Reinecke,
K. Rohatsch,
O. Schulz,
A. Sörensen,
I. Stekl,
J. Tebrügge,
R. Temminghoff
, et al. (6 additional authors not shown)
Abstract:
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges fa…
▽ More
The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges faced when operating CdZnTe detectors in low-background mode, to identify potential background sources and to show the long-term stability of the detectors. The first data-taking period started in 2011 with a subset of the detectors, while the demonstrator was completed in November 2013. To date, more than 250kg d of data have been collected. This paper describes technical details of the experimental setup and the hardware components.
△ Less
Submitted 18 November, 2015; v1 submitted 29 July, 2015;
originally announced July 2015.