-
Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments
Authors:
Byeong Rok Ko,
Andrew K. Yi
Abstract:
Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the exper…
▽ More
Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. In order to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.
△ Less
Submitted 22 May, 2025; v1 submitted 2 March, 2025;
originally announced March 2025.
-
Maximizing Quantum Enhancement in Axion Dark Matter Experiments
Authors:
Chao-Lin Kuo,
Chelsea L. Bartram,
Aaron S. Chou,
Taj A. Dyson,
Noah A. Kurinsky,
Gray Rybka,
Osmond Wen,
Matthew O. Withers,
Andrew K. Yi,
Cheng Zhang
Abstract:
We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1--30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies ($ν>$ 5 GHz), {\em if} they can be impl…
▽ More
We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1--30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies ($ν>$ 5 GHz), {\em if} they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the over-coupling regime, up to $β\sim 10$; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.
△ Less
Submitted 20 November, 2024;
originally announced November 2024.
-
Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears
Authors:
A. K. Yi,
T. Seong,
S. Lee,
S. Ahn,
B. I. Ivanov,
S. V. Uchaikin,
B. R. Ko,
Y. K. Semertzidis
Abstract:
Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable fre…
▽ More
Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. We, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42\% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.
△ Less
Submitted 8 July, 2024; v1 submitted 11 June, 2024;
originally announced June 2024.
-
Electromagnetic modeling and science reach of DMRadio-m$^3$
Authors:
DMRadio Collaboration,
A. AlShirawi,
V. Ankel,
C. Bartram,
J. Begin,
C. Bell,
J. N. Benabou,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
S. Cuadra,
A. Droster,
J. Echevers,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner
, et al. (23 additional authors not shown)
Abstract:
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we pres…
▽ More
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30--200 MHz can be achieved with a $3σ$ live scan time of 2.9 years.
△ Less
Submitted 6 May, 2025; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Fast DAQ system with image rejection for axion dark matter searches
Authors:
S. Ahn,
M. J. Lee,
A. K. Yi,
B. Yeo,
B. R. Ko,
Y. K. Semertzidis
Abstract:
A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast F…
▽ More
A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast Fourier transforms (FFTs). Using an IQ mixer and two parallel DAQ channels, we then also implemented a software-based image rejection without losing the DAQ efficiency. This work extends our continuing effort to improve the figure of merit in axion haloscope searches, the scanning rate.
△ Less
Submitted 17 April, 2022; v1 submitted 16 September, 2021;
originally announced September 2021.
-
Axion Dark Matter Research with IBS/CAPP
Authors:
Yannis K. Semertzidis,
Jihn E. Kim,
SungWoo Youn,
Jihoon Choi,
Woohyun Chung,
Selcuk Haciomeroglu,
Dongmin Kim,
Jingeun Kim,
ByeongRok Ko,
Ohjoon Kwon,
Andrei Matlashov,
Lino Miceli,
Hiroaki Natori,
Seongtae Park,
MyeongJae Lee,
Soohyung Lee,
Elena Sala,
Yunchang Shin,
Taehyeon Seong,
Sergey Uchaykin,
Danho Ahn,
Saebyeok Ahn,
Seung Pyo Chang,
Wheeyeon Cheong,
Hoyong Jeong
, et al. (12 additional authors not shown)
Abstract:
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on th…
▽ More
The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.
△ Less
Submitted 25 October, 2019;
originally announced October 2019.