-
Simultaneous existence of the ocsillations, counterstreaming flows and mass injections in solar quiescent prominences
Authors:
X. L. Yan,
Z. K. Xue,
J. C. Wang,
P. F. Chen,
K. F. Ji,
C. Xia,
L. H. Yang,
D. F. Kong,
Z. Xu,
Y. A. Zhou,
Q. L. Li
Abstract:
Solar prominences are very spectacular structures embedded in the tenuous and hot solar corona. The counterstreaming flows, a common feature in solar quiescent prominences, have been discovered for more than twenty years. However, the mechanism driving the counterstreaming flows is still elusive. To unveil the nature of this phenomenon, we analyzed the data of a quiescent prominence observed by th…
▽ More
Solar prominences are very spectacular structures embedded in the tenuous and hot solar corona. The counterstreaming flows, a common feature in solar quiescent prominences, have been discovered for more than twenty years. However, the mechanism driving the counterstreaming flows is still elusive. To unveil the nature of this phenomenon, we analyzed the data of a quiescent prominence observed by the New Vacuum Solar Telescope (NVST), the Interface Region Imaging Spectrograph (IRIS), and the Solar Dynamical Observatory (SDO). It is found that there is a distinct longitudinal oscillation of prominence plasma along the higher part of the prominence spine in H$α$ observations. The oscillation period is approximately 83 minutes and the amplitude is about 32 Mm. The counterstreaming flows are dominant in the middle part of the prominence spine. The velocities of the counterstreaming flows range from about 4 km s$^{-1}$ to 11 km s$^{-1}$. Moreover, the intermittent mass flows with the upward plumes from the top of the bubbles and tornado-like barbs are observed to be injected into the lower part of the prominence spine from the lower atmosphere. The velocities of these injected mass flows range from about 3 km s$^{-1}$ to 30 km s$^{-1}$. Some injected mass flows exhibit redshifted Doppler signals, while others exhibit blueshifted signals. Based on these high resolution observations, it is found that different parts of the prominence spine exhibit the different dynamic characteristics. These results further advance the understanding of the ubiquitous counterstreaming flows in solar quiescent prominences.
△ Less
Submitted 6 February, 2025;
originally announced February 2025.
-
The hidden magnetic structures of a solar intermediate filament revealed by the injected flare material
Authors:
X. L. Yan,
Z. K. Xue,
J. C. Wang,
L. H. Yang,
K. F. Ji,
D. F. Kong,
Z. Xu,
Q. L. Li,
L. P. Yang,
X. S. Zhang
Abstract:
Solar filaments are spectacular objects in the solar atmosphere, consisting of accumulations of cool, dense, and partially ionized plasma suspended in the hot solar corona against gravity. The magnetic structures that support the filament material remain elusive, partly due to the lack of high resolution magnetic field measurements in the chromosphere and corona. In this study, we reconstruct the…
▽ More
Solar filaments are spectacular objects in the solar atmosphere, consisting of accumulations of cool, dense, and partially ionized plasma suspended in the hot solar corona against gravity. The magnetic structures that support the filament material remain elusive, partly due to the lack of high resolution magnetic field measurements in the chromosphere and corona. In this study, we reconstruct the magnetic structures of a solar intermediate filament using EUV observations and two different methods, to follow the injection of hot material from a B-class solar flare. Our analysis reveals the fine-scale magnetic structures of the filament, including a compact set of mutually wrapped magnetic fields encasing the cool filament material, two groups of helical magnetic structures intertwining with the main filament, and a series of arched magnetic loops positioned along the filament. Additionally, we also find that the northern footpoints of the helical structures are rooted in the same location, while their southern footpoints are rooted in different areas. The results obtained in this study offer new insights into the formation and eruption mechanisms of solar filaments.
△ Less
Submitted 2 December, 2024;
originally announced December 2024.
-
Phase-Imaging Ion-Cyclotron-Resonance Mass Spectrometry with the Canadian Penning Trap at CARIBU
Authors:
D. Ray,
A. A. Valverde,
M. Brodeur,
F. Buchinger,
J. A. Clark,
B. Liu,
G. E. Morgan,
R. Orford,
W. S. Porter,
G. Savard,
K. S. Sharma,
X. L. Yan
Abstract:
The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PIICR) technique for over half a decade. Here we discuss the CPT system, and met…
▽ More
The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PIICR) technique for over half a decade. Here we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.
△ Less
Submitted 27 April, 2025; v1 submitted 17 July, 2024;
originally announced July 2024.
-
$Bρ$-defined isochronous mass spectrometry: a new approach for high-precision mass measurements of short-lived nuclei
Authors:
M. Wang,
M. Zhang,
X. Zhou,
Y. H. Zhang,
Yu. A. Litvinov,
H. S. Xu,
R. J. Chen,
H. Y. Deng,
C. Y. Fu,
W. W. Ge,
H. F. Li,
T. Liao,
S. A. Litvinov,
P. Shuai,
J. Y. Shi,
M. Si,
R. S. Sidhu,
Y. N. Song,
M. Z. Sun,
S. Suzuki,
Q. Wang,
Y. M. Xing,
X. Xu,
T. Yamaguchi,
X. L. Yan
, et al. (4 additional authors not shown)
Abstract:
A novel technique for broadband high-precision mass measurements of short-lived exotic nuclides is reported. It is based on the isochronous mass spectrometry (IMS) and realizes simultaneous determinations of revolution time and velocity of short-lived stored ions at the cooler storage ring CSRe in Lanzhou. The new technique, named as the $Bρ$-defined IMS or $Bρ$-IMS, boosts the efficiency, sensiti…
▽ More
A novel technique for broadband high-precision mass measurements of short-lived exotic nuclides is reported. It is based on the isochronous mass spectrometry (IMS) and realizes simultaneous determinations of revolution time and velocity of short-lived stored ions at the cooler storage ring CSRe in Lanzhou. The new technique, named as the $Bρ$-defined IMS or $Bρ$-IMS, boosts the efficiency, sensitivity, and accuracy of mass measurements, and is applied here to measure masses of neutron-deficient $fp$-shell nuclides. In a single accelerator setting, masses of $^{46}$Cr, $^{50}$Fe and $^{54}$Ni are determined with relative uncertainties of (5~-~6)$\times10^{-8}$, thereby improving the input data for testing the unitarity of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. This is the technique of choice for future high-precision measurements of the most rarely produced shortest-lived nuclides.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Experimental Investigation of the Transition Energy $γ_t$ in the Isochronous Mode of the HIRFL-CSRe
Authors:
W. W. Ge,
Y. J. Yuan,
J. C. Yang,
R. J. Chen,
X. L. Yan,
H. Du,
Z. S. Li,
J. Yang,
D. Y. Yin,
L. J. Mao,
X. N. Li,
W. H. Zheng,
G. D. Shen,
B. Wu,
S. Ruan,
G. Wang,
H. Zhao,
M. Wang,
M. Z. Sun,
Y. M. Xing,
P. Zhang,
C. Y. Fu,
P. Shuai,
X. Xu,
Y. H. Zhang
, et al. (9 additional authors not shown)
Abstract:
The Isochronous Mass Spectrometry (IMS) based on storage rings is a powerful technique for mass measurement of short-lived exotic nuclei. The transition energy $γ_t$ of the storage ring is a vital parameter of the IMS technique. It is difficult to measure the $γ_t$ and its relation to momentum spread or circulating length, especially to monitor the variation of $γ_t$ during experiments. An experim…
▽ More
The Isochronous Mass Spectrometry (IMS) based on storage rings is a powerful technique for mass measurement of short-lived exotic nuclei. The transition energy $γ_t$ of the storage ring is a vital parameter of the IMS technique. It is difficult to measure the $γ_t$ and its relation to momentum spread or circulating length, especially to monitor the variation of $γ_t$ during experiments. An experimental investigation on the $γ_t$ has been performed for the IMS experiment at the Cooler Storage Ring of the Heavy Ion Research Facility in Lanzhou (HIRFL-CSRe). With the velocity measured by two time-of-flight (TOF) detectors, the $γ_t$ as a function of orbital length can be determined. The influences of higher order magnetic field components on the $γ_t$ function were inferred for isochronous correction. This paper introduces and investigates the influence of dipole magnetic fields, quadrupole magnetic fields and sextupole magnetic fields on the $γ_t$ function. With the quadrupole magnets and sextupole magnets corrections, a mass resolution of 171332 (FWHM) and $σ(T)/T=1.34\times10^{-6}$ were reached, which shall be compared with 31319 (FWHM) and $σ(T)/T=7.35\times10^{-6}$ obtained without correction.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
A method to measure the transition energy $γ_{t}$ of the isochronously tuned storage ring
Authors:
R. J. Chen,
X. L. Yan,
W. W. Ge,
Y. J. Yuan,
M. Wang,
M. Z. Sun,
Y. M. Xing,
P. Zhang,
C. Y. Fu,
P. Shuai,
X. Xu,
Y. H. Zhang,
T. Bao,
X. C. Chen,
X. J. Hu,
W. J. Huang,
H. F. Li,
J. H. Liu,
Yu. A. Litvinov,
S. A. Litvinov,
L. J. Mao,
B. Wu,
H. S. Xu,
J. C. Yang,
D. Y. Yin
, et al. (5 additional authors not shown)
Abstract:
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has bee…
▽ More
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has been a challenge to determine the $γ_{t}$ and especially to monitor the variation of $γ_{t}$ during experiments. In this paper we introduce a method to measure the $γ_{t}$ online during IMS experiments by using the acquired experimental data. Furthermore, since the storage ring has (in our context) a relatively large momentum acceptance, the variation of the $γ_{t}$ across the ring acceptance is a source of systematic uncertainty of measured masses. With the installation of two time-of-flight (TOF) detectors, the velocity of each stored ion and its revolution time are simultaneously available for the analysis. These quantities enabled us to determine the $γ_{t}$ as a function of orbital length in the ring. The presented method is especially important for future IMS experiments planned at the new-generation storage ring facilities FAIR in Germany and HIAF in China.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors
Authors:
P. Shuai,
X. Xu,
Y. H. Zhang,
H. S. Xu,
Yu. A. Litvinov,
M. Wang,
X. L. Tu,
K. Blaum,
X. H. Zhou,
Y. J. Yuan,
X. L. Yan,
X. C. Chen,
R. J. Chen,
C. Y. Fu,
Z. Ge,
W. J. Huang,
Y. M. Xing,
Q. Zeng
Abstract:
Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum mea…
▽ More
Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.
△ Less
Submitted 1 March, 2016; v1 submitted 25 January, 2016;
originally announced January 2016.