First results of AUP Nb3Sn quadrupole horizontal tests
Authors:
M. Baldini,
G. Ambrosio,
G. Apollinari,
J. Blowers,
R. Bossert,
R. Carcagno,
G. Chlachidze,
J. DiMarco,
S. Feher,
S. Krave,
V. Lombardo,
L. Martin,
C. Narug,
T. H. Nicol,
V. Nikolic,
A. Nobrega,
V. Marinozzi,
C. Orozco,
T. Page,
S. Stoynev,
T. Strauss,
M. Turenne,
D. Turrioni,
A. Vouris,
M. Yu
, et al. (26 additional authors not shown)
Abstract:
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a…
▽ More
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a CERN project with a world-wide collaboration. It is under construction and utilizes Nb3Sn Magnets (named MQXF) as key ingredients to increase tenfold the integrated luminosity delivered to the CMS and ATLAS experiments in the next decade.
The HL-LHC AUP is the US effort to contribute approximately 50% of the low-beta focusing magnets and crab cavities for the HL-LHC.
This paper will present the program to fabricate the Nb3Sn superconducting magnets. We are reporting the status of the HL-LHC AUP project present the results from horizontal tests of the first fully assembled cryo-assembly.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Effect of CLIQ on training of HL-LHC quadrupole magnets
Authors:
S. Stoynev,
G. Ambrosio,
K. Amm,
J. DiMarco,
S. Feher,
P. Ferracin,
V. Marinozzi,
S. Prestemon,
A. B. Yahia
Abstract:
The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb3Sn magnets to be used in any large particle accelerator. At development stages, many Nb3Sn accelera…
▽ More
The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb3Sn magnets to be used in any large particle accelerator. At development stages, many Nb3Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based devices can affect Nb3Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. The present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.
△ Less
Submitted 7 February, 2024; v1 submitted 5 February, 2024;
originally announced February 2024.
-
Analysis of the mechanical performance of the 4.2 m long MQXFA magnets for the Hi-Lumi LHC Upgrade
Authors:
L. Garcia Fajardo,
G. Ambrosio,
A. Ben Yahia,
D. W. Cheng,
P. Ferracin,
J. Ferradas Troitino,
S. Izquierdo Bermudez,
J. Muratore,
S. Prestemon,
K. L. Ray,
M. Solis,
G. Vallone
Abstract:
Under the U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), the 150 mm bore, high-field Nb3Sn low-\b{eta} MQXFA quadrupole magnets are being fabricated, assembled and tested, in the context of the CERN Hi-Luminosity LHC (HL-LHC) upgrade. These magnets have 4.2 m magnetic length and 4.56 m long iron yoke. To date, eight MQXFA magnets have been tested. One of the magnets additionall…
▽ More
Under the U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), the 150 mm bore, high-field Nb3Sn low-\b{eta} MQXFA quadrupole magnets are being fabricated, assembled and tested, in the context of the CERN Hi-Luminosity LHC (HL-LHC) upgrade. These magnets have 4.2 m magnetic length and 4.56 m long iron yoke. To date, eight MQXFA magnets have been tested. One of the magnets additionally underwent a successful endurance test with 40 triggered quenches, and two magnets did not perform as expected. This work summarizes for the first time the available strain gauge data from eight identical Nb3Sn MQXFA tested magnets, focusing on the endurance test, and on a possible cause of underperformance of the two magnets that did not pass the vertical test. We applied methods to prevent this from happening in future MQXFA magnets, which shown to be effective for last two tested magnets.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.
-
Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
G. Arnau Izquierdo,
M. Baldini,
A. Ballarino,
C. Barth,
A. Ben Yahia,
J. Blowers,
P. Borges De Sousa,
R. Bossert,
B. Bulat,
R. Carcagno,
D. W. Cheng,
G. Chlachidze,
L. Cooley,
M. Crouvizier,
A. Devred,
J. DiMarco,
S. Feher,
P. Ferracin,
J. Ferradas Troitino,
L. Garcia Fajardo,
S. Gourlay
, et al. (33 additional authors not shown)
Abstract:
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of th…
▽ More
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Common Coil Dipole for High Field Magnet Design and R&D
Authors:
Ramesh Gupta,
Kathleen Amm,
Julien Avronsart,
Michael Anerella,
Anis Ben Yahia,
John Cozzolino,
Piyush Joshi,
Mithlesh Kumar,
Febin Kurian,
Chris Runyan,
William Sampson,
Jesse Schmalzle,
Stephan Kahn,
Ronald Scanlan,
Robert Weggel,
Erich Willen,
Qingjin Xu,
Javier Munilla,
Fernando Toral,
Paolo Ferracin,
Steve Gourlay,
GianLuca Sabbi,
Xiaorong Wang,
Danko van der Laan,
Jeremy Weiss
Abstract:
The common coil geometry provides an alternate design to the conventional cosine theta dipoles. It allows a wider range of conductor and magnet technologies. It also facilitates a low-cost, rapid-turn-around design and R&D program. Recent studies carried out as a part of the US Magnet Development Program revealed that at high fields (20 T with 15% operating margin or more), the common coil design…
▽ More
The common coil geometry provides an alternate design to the conventional cosine theta dipoles. It allows a wider range of conductor and magnet technologies. It also facilitates a low-cost, rapid-turn-around design and R&D program. Recent studies carried out as a part of the US Magnet Development Program revealed that at high fields (20 T with 15% operating margin or more), the common coil design also uses significantly less conductor (particularly much less HTS), as compared to that in the other designs.
△ Less
Submitted 16 March, 2022;
originally announced March 2022.
-
REBCO -- a silver bullet for our next high-field magnet and collider budget?
Authors:
Xiaorong Wang,
Anis Ben Yahia,
Ernesto Bosque,
Paolo Ferracin,
Stephen Gourlay,
Ramesh Gupta,
Hugh Higley,
Vadim Kashikhin,
Mithlesh Kumar,
Vito Lombardo,
Maxim Marchevsky,
Reed Teyber,
Sofia Viarengo
Abstract:
High-field superconducting magnets with a dipole field of 16 T and above enable future energy-frontier circular particle colliders. Although we believe these magnets can be built, none exists today. They can also be a showstopper for future high-energy machines due to a prohibitively high price tag based on the current conductor and magnet fabrication cost. The high-temperature superconducting REB…
▽ More
High-field superconducting magnets with a dipole field of 16 T and above enable future energy-frontier circular particle colliders. Although we believe these magnets can be built, none exists today. They can also be a showstopper for future high-energy machines due to a prohibitively high price tag based on the current conductor and magnet fabrication cost. The high-temperature superconducting REBCO coated conductor can address both the technical and cost issues, a silver bullet to lay both monsters to rest. The challenges and unknowns, however, can be too arduous to make the silver bullet. We lay out a potential road forward and suggest key action items. As a contribution from the accelerator community, we attempt to clarify for our theorist and experimenter colleagues a few aspects about the future high-field superconducting magnets. We hope to stimulate an effective plan for the 2023 P5 process that can lead to a cost-effective high-field magnet technology for future colliders and the exciting physics they can steward.
△ Less
Submitted 21 March, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
White Paper on Leading-Edge technology And Feasibility-directed (LEAF) Program aimed at readiness demonstration for Energy Frontier Circular Colliders by the next decade
Authors:
G. Ambrosio,
G. Apollinari,
M. Baldini,
R. Carcagno,
C. Boffo,
B. Claypool,
S. Feher,
S. Hays,
D. Hoang,
V. Kashikhin,
V. V. Kashikhin,
S. Krave,
M. Kufer,
J. Lee,
V. Lombardo,
V. Marinozzi,
F. Nobrega,
X. Peng,
H. Piekarz,
V. Shiltsev,
S. Stoynev,
T. Strauss,
N. Tran,
G. Velev,
X. Xu
, et al. (17 additional authors not shown)
Abstract:
In this White Paper for the Snowmass 2021 Process, we propose the establishment of a magnet Leading-Edge technology And Feasibility-directed Program (LEAF Program) to achieve readiness for a future collider decision on the timescale of the next decade.
The LEAF Program would rely on, and be synergetic with, generic R&D efforts presently covered - in the US - by the Magnet Development Program (MD…
▽ More
In this White Paper for the Snowmass 2021 Process, we propose the establishment of a magnet Leading-Edge technology And Feasibility-directed Program (LEAF Program) to achieve readiness for a future collider decision on the timescale of the next decade.
The LEAF Program would rely on, and be synergetic with, generic R&D efforts presently covered - in the US - by the Magnet Development Program (MDP), the Conductor Procurement and R&D (CPRD) Program and other activities in the Office of HEP supported by Early Career Awards (ECA) or Lab Directed R&D (LDRD) funds. Where possible, ties to synergetic efforts in other Offices of DOE or NSF are highlighted and suggested as wider Collaborative efforts on the National scale. International efforts are also mentioned as potential partners in the LEAF Program.
We envision the LEAF Program to concentrate on demonstrating the feasibility of magnets for muon colliders as well as next generation high energy hadron colliders, pursuing, where necessary and warranted by the nature of the application, the transition from R&D models to long models/prototypes. The LEAF Program will naturally drive accelerator-quality and experiment-interface design considerations. LEAF will also concentrate, where necessary, on cost reduction and/or industrialization steps.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
MQXFA Final Design Report
Authors:
Giorgio Ambrosio,
Kathleen Amm,
Mike Anerella,
Giorgio Apollinari,
Maria Baldini,
Anis Ben Yahia,
James Blowers,
Ruben Carcagno,
Daniel Cheng,
Guram Chlachidze,
Lance Cooley,
Sandor Feher,
Paolo Ferracin,
Henry Hocker,
Susana Izquierdo Bermudez,
Piyush Joshi,
Vito Lombardo,
Vittorio Marinozzi,
Joseph Muratore,
Michael Naus,
Fred Nobrega,
Heng Pan,
Marcellus Parker,
Ian Pong,
Soren Prestemon
, et al. (7 additional authors not shown)
Abstract:
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, man…
▽ More
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.
*Supported by the U.S. Department of Energy, Office of Science, Office of High Energy Physics
△ Less
Submitted 13 March, 2022;
originally announced March 2022.