-
Robust incoherent perfect absorption
Authors:
H. S. Xu,
L. Jin
Abstract:
A coherent perfect absorber is capable of completely absorbing input waves. However, the coherent perfect absorption severely depends on the superposition of the input waves, and the perfect absorption is sensitive to the disorder of the absorber. Thus, a robust incoherent perfect absorption, being insensitive to the superposition of input waves and the system disorder, is desirable for practical…
▽ More
A coherent perfect absorber is capable of completely absorbing input waves. However, the coherent perfect absorption severely depends on the superposition of the input waves, and the perfect absorption is sensitive to the disorder of the absorber. Thus, a robust incoherent perfect absorption, being insensitive to the superposition of input waves and the system disorder, is desirable for practical applications. Here, we demonstrate that the linearly independent destructive interference at the port connections removes the constraint on the coherent input. We propose an approach using the interplay between the loss and localization to form the incoherent perfect absorption. The resonant incidence from either port is completely absorbed. Furthermore, we utilize the lattice configuration supporting the flat band to demonstrate the disorder-immune incoherent perfect absorption. Our findings provide insight into the fundamentals and applications for the perfect absorption of light, microwaves, sound, mechanical waves, and beyond.
△ Less
Submitted 5 April, 2024;
originally announced April 2024.
-
Pseudo-Hermiticity protects the energy-difference conservation in the scattering
Authors:
H. S. Xu,
L. Jin
Abstract:
Symmetry plays a fundamentally important role in physics. In this work, we find a conservation law, $S^{\dagger}(H_{c}^{\dagger})S(H_{c})=I$, which is valid for any non-Hermitian scattering center $H_c$. As a result, the reflections and transmissions of a non-Hermitian system $\left\{ r,t\right\}$ and its Hermitian conjugation system $\left\{ \bar{r},\bar{t}\right\} $ satisfy the conservation law…
▽ More
Symmetry plays a fundamentally important role in physics. In this work, we find a conservation law, $S^{\dagger}(H_{c}^{\dagger})S(H_{c})=I$, which is valid for any non-Hermitian scattering center $H_c$. As a result, the reflections and transmissions of a non-Hermitian system $\left\{ r,t\right\}$ and its Hermitian conjugation system $\left\{ \bar{r},\bar{t}\right\} $ satisfy the conservation law $\bar{r}^{\ast}r+\bar{t}^{\ast}t=1$, instead of the energy conservation law that applies to incoming and outgoing waves in a Hermitian system. Consequently, the pseudo-Hermiticity of a non-Hermitian system ensures an energy-difference conservation. Furthermore, we demonstrate that the energy-difference conservation is respectively valid and invalid in two prototypical anti-$\mathcal{PT}$-symmetric systems, where the energy-difference conservation is protected by the pseudo-Hermiticity. Our findings provide profound insight into the conservation law, the pseudo-Hermiticity, and the anti-$\mathcal{PT}$-symmetry in non-Hermitian systems.
△ Less
Submitted 4 October, 2023;
originally announced October 2023.
-
Tunable Aharonov-Bohm cages through anti-$\mathcal{PT}$-symmetric imaginary couplings
Authors:
S. M. Zhang,
H. S. Xu,
L. Jin
Abstract:
The Aharonov-Bohm (AB) cage enables localized confinement with nondiffractive propagation for arbitrary excitation. In this study, we introduce an anti-parity-time (anti-$\mathcal{PT}$) symmetric imaginary coupling in a generalized Creutz ladder to construct a non-Hermitian AB cage with tunable flat-band energy. We investigate compact localized states and complete localization dynamics, and show t…
▽ More
The Aharonov-Bohm (AB) cage enables localized confinement with nondiffractive propagation for arbitrary excitation. In this study, we introduce an anti-parity-time (anti-$\mathcal{PT}$) symmetric imaginary coupling in a generalized Creutz ladder to construct a non-Hermitian AB cage with tunable flat-band energy. We investigate compact localized states and complete localization dynamics, and show that non-Hermiticity affects the localization probability distributions and increases the oscillation period of the AB cage dynamics. Non-Hermitian engineering of the decoupled core of the AB cage is the essential point in our proposal. Our approach is widely applicable to a more general situation and can facilitate the manipulation of localization in physics.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
High-order spectral singularity
Authors:
H. S. Xu,
L. C. Xie,
L. Jin
Abstract:
Exceptional point and spectral singularity are two types of singularity that are unique to non-Hermitian systems. Here, we report the high-order spectral singularity as a high-order pole of the scattering matrix for a non-Hermitian scattering system, and the high-order spectral singularity is a unification of the exceptional point and spectral singularity. At the high-order spectral singularity, t…
▽ More
Exceptional point and spectral singularity are two types of singularity that are unique to non-Hermitian systems. Here, we report the high-order spectral singularity as a high-order pole of the scattering matrix for a non-Hermitian scattering system, and the high-order spectral singularity is a unification of the exceptional point and spectral singularity. At the high-order spectral singularity, the scattering coefficients have high-order divergence and the scattering system stimulates high-order lasing. The wave emission intensity is polynomially enhanced, and the order of the growth in the polynomial intensity linearly scales with the order of the spectral singularity. Furthermore, the coherent input controls and alters the order of the spectral singularity. Our findings provide profound insights into the fundamentals and applications of high-order spectral singularities.
△ Less
Submitted 9 June, 2023;
originally announced June 2023.
-
$Bρ$-defined isochronous mass spectrometry: a new approach for high-precision mass measurements of short-lived nuclei
Authors:
M. Wang,
M. Zhang,
X. Zhou,
Y. H. Zhang,
Yu. A. Litvinov,
H. S. Xu,
R. J. Chen,
H. Y. Deng,
C. Y. Fu,
W. W. Ge,
H. F. Li,
T. Liao,
S. A. Litvinov,
P. Shuai,
J. Y. Shi,
M. Si,
R. S. Sidhu,
Y. N. Song,
M. Z. Sun,
S. Suzuki,
Q. Wang,
Y. M. Xing,
X. Xu,
T. Yamaguchi,
X. L. Yan
, et al. (4 additional authors not shown)
Abstract:
A novel technique for broadband high-precision mass measurements of short-lived exotic nuclides is reported. It is based on the isochronous mass spectrometry (IMS) and realizes simultaneous determinations of revolution time and velocity of short-lived stored ions at the cooler storage ring CSRe in Lanzhou. The new technique, named as the $Bρ$-defined IMS or $Bρ$-IMS, boosts the efficiency, sensiti…
▽ More
A novel technique for broadband high-precision mass measurements of short-lived exotic nuclides is reported. It is based on the isochronous mass spectrometry (IMS) and realizes simultaneous determinations of revolution time and velocity of short-lived stored ions at the cooler storage ring CSRe in Lanzhou. The new technique, named as the $Bρ$-defined IMS or $Bρ$-IMS, boosts the efficiency, sensitivity, and accuracy of mass measurements, and is applied here to measure masses of neutron-deficient $fp$-shell nuclides. In a single accelerator setting, masses of $^{46}$Cr, $^{50}$Fe and $^{54}$Ni are determined with relative uncertainties of (5~-~6)$\times10^{-8}$, thereby improving the input data for testing the unitarity of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. This is the technique of choice for future high-precision measurements of the most rarely produced shortest-lived nuclides.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Coherent resonant transmission
Authors:
H. S. Xu,
L. Jin
Abstract:
The reflectionless coherent light transport in the coupled resonator array is investigated in the presence of intra-resonator intermodal coupling between the clockwise and counterclockwise modes, which plays a constructive role for modulating the light flow rather than inducing the unwanted backscattering. The interplay between the intra-resonator intermodal coupling and the inter-resonator coupli…
▽ More
The reflectionless coherent light transport in the coupled resonator array is investigated in the presence of intra-resonator intermodal coupling between the clockwise and counterclockwise modes, which plays a constructive role for modulating the light flow rather than inducing the unwanted backscattering. The interplay between the intra-resonator intermodal coupling and the inter-resonator couplings enables the coherent resonant transmission (CRT) of the properly superposed injection constituted by the clockwise and counterclockwise modes. The superposition coefficients of the initial excitation determine the mode chirality of the resonant transmission. Sequentially experiencing the time-reversal process of CRT and the CRT realizes the perfect mode conversion that the mode chirality of the injection wave switches into the opposite after resonant transmission. Our findings on the coherent light transport provide insights for the control and manipulation of light field in the integrated photonics, nanophotonics, chiral optics, and beyond.
△ Less
Submitted 28 July, 2022;
originally announced July 2022.
-
Storage ring mass spectrometry for nuclear structure and astrophysics research
Authors:
Y. H. Zhang,
Yu. A. Litvinov,
T. Uesaka,
H. S. Xu
Abstract:
In the last two and a half decades ion storage rings have proven to be powerful tools for precision experiments with unstable nuclides in realm of nuclear structure and astrophysics. There are presently three storage ring facilities in the world at which experiments with stored radioactive ions are possible. These are the ESR in GSI, Darmstadt/Germany, the CSRe in IMP, Lanzhou/China, and the R3 st…
▽ More
In the last two and a half decades ion storage rings have proven to be powerful tools for precision experiments with unstable nuclides in realm of nuclear structure and astrophysics. There are presently three storage ring facilities in the world at which experiments with stored radioactive ions are possible. These are the ESR in GSI, Darmstadt/Germany, the CSRe in IMP, Lanzhou/China, and the R3 storage ring in RIKEN, Saitama/Japan. In this work, an introduction to the facilities is given. Selected characteristic experimental results and their impact in nuclear physics and astrophysics are presented. Planned technical developments and the envisioned future experiments are outlined.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
A method to measure the transition energy $γ_{t}$ of the isochronously tuned storage ring
Authors:
R. J. Chen,
X. L. Yan,
W. W. Ge,
Y. J. Yuan,
M. Wang,
M. Z. Sun,
Y. M. Xing,
P. Zhang,
C. Y. Fu,
P. Shuai,
X. Xu,
Y. H. Zhang,
T. Bao,
X. C. Chen,
X. J. Hu,
W. J. Huang,
H. F. Li,
J. H. Liu,
Yu. A. Litvinov,
S. A. Litvinov,
L. J. Mao,
B. Wu,
H. S. Xu,
J. C. Yang,
D. Y. Yin
, et al. (5 additional authors not shown)
Abstract:
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has bee…
▽ More
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has been a challenge to determine the $γ_{t}$ and especially to monitor the variation of $γ_{t}$ during experiments. In this paper we introduce a method to measure the $γ_{t}$ online during IMS experiments by using the acquired experimental data. Furthermore, since the storage ring has (in our context) a relatively large momentum acceptance, the variation of the $γ_{t}$ across the ring acceptance is a source of systematic uncertainty of measured masses. With the installation of two time-of-flight (TOF) detectors, the velocity of each stored ion and its revolution time are simultaneously available for the analysis. These quantities enabled us to determine the $γ_{t}$ as a function of orbital length in the ring. The presented method is especially important for future IMS experiments planned at the new-generation storage ring facilities FAIR in Germany and HIAF in China.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
First application of combined isochronous and Schottky mass spectrometry: Half-lives of fully ionized 49Cr24+ and 53Fe26+ atoms
Authors:
X. L. Tu,
X. C. Chen,
J. T. Zhang,
P. Shuai,
K. Yue,
X. Xu,
C. Y. Fu,
Q. Zeng,
X. Zhou,
Y. M. Xing,
J. X. Wu,
R. S. Mao,
L. J. Mao,
K. H. Fang,
Z. Y. Sun,
M. Wang,
J. C. Yang,
Yu. A. Litvinov,
K. Blaum,
Y. H. Zhang,
Y. J. Yuan,
X. W. Ma,
X. H. Zhou,
H. S. Xu
Abstract:
Lifetime measurements of b -decaying highly charged ions have been performed in the storage ring CSRe by applying the isochronous Schottky mass spectrometry. The fully ionized 49Cr and 53Fe ions were produced in projectile fragmentation of 58Ni primary beam and were stored in the CSRe tuned into the isochronous ion-optical mode. The new resonant Schottky detector was applied to monitor the intensi…
▽ More
Lifetime measurements of b -decaying highly charged ions have been performed in the storage ring CSRe by applying the isochronous Schottky mass spectrometry. The fully ionized 49Cr and 53Fe ions were produced in projectile fragmentation of 58Ni primary beam and were stored in the CSRe tuned into the isochronous ion-optical mode. The new resonant Schottky detector was applied to monitor the intensities of stored uncooled 49Cr24+ and 53Fe26+ ions. The extracted half-lives T1/2(49Cr24+) = 44.0(27) min and T1/2(53Fe26+) = 8.47(19) min are in excellent agreement with the literature half-life values corrected for the disabled electron capture branchings. This is an important proof-of-principle step towards realizing the simultaneous mass and lifetime measurements on exotic nuclei at the future storage ring facilities.
△ Less
Submitted 8 April, 2018;
originally announced April 2018.
-
An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors
Authors:
P. Shuai,
X. Xu,
Y. H. Zhang,
H. S. Xu,
Yu. A. Litvinov,
M. Wang,
X. L. Tu,
K. Blaum,
X. H. Zhou,
Y. J. Yuan,
X. L. Yan,
X. C. Chen,
R. J. Chen,
C. Y. Fu,
Z. Ge,
W. J. Huang,
Y. M. Xing,
Q. Zeng
Abstract:
Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum mea…
▽ More
Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.
△ Less
Submitted 1 March, 2016; v1 submitted 25 January, 2016;
originally announced January 2016.
-
The performance of a double sided silicon strip detector as a transmission detector for heavy ions
Authors:
J L Han,
J B Ma,
X G Cao,
Q Wang,
J S Wang,
Y Y Yang,
P Ma,
M R Huang,
S L Jin,
X J Rong,
Z Bai,
F Fu,
Q Hu,
R F Chen,
S W Xu,
J B Chen,
L Jin,
Y Li,
M H Zhao,
H S Xu
Abstract:
The performance of a double sided silicon strip detector (DSSSD), used for position and energy detection of heavy ions, is reported. The analysis shows that the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, however the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectr…
▽ More
The performance of a double sided silicon strip detector (DSSSD), used for position and energy detection of heavy ions, is reported. The analysis shows that the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, however the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectra are shown and their origins are confirmed by correlation analysis of the spectra from both junction side and ohmic side of the DSSSD.
△ Less
Submitted 15 July, 2013;
originally announced July 2013.
-
Longitudinal Schottky spectra of a bunched Ne10+ ion beam at the CSRe
Authors:
W. Q. Wen,
X. Ma,
D. C. Zhang,
X. L. Zhu,
L. J. Meng,
J. Li,
H. P. Liu,
D. M. Zhao,
Z. S. Wang,
R. S. Mao,
T. C. Zhao,
J. X. Wu,
X. M. Ma,
T. L. Yan,
G. H. Li,
X. D. Yang,
Y. Liu,
J. C. Yang,
Y. J. Yuan,
J. W. Xia,
H. S. Xu,
G. Q. Xiao,
H. W. Zhao
Abstract:
The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of has been reached with less than 107 stored ions. The reduction of momentum spread compared with coas…
▽ More
The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of has been reached with less than 107 stored ions. The reduction of momentum spread compared with coasting ion beam was observed from Schottky noise signal of the bunched ion beam. In order to prepare the future laser cooling experiment at the CSRe, the RF-bunching power was modulated at 25th, 50th and 75th harmonic of the revolution frequency, effective bunching amplitudes were extracted from the Schottky spectrum analysis. Applications of Schottky noise for measuring beam lifetime with ultra-low intensity of ion beams are presented, and it is relevant to upcoming experiments on laser cooling of relativistic heavy ion beams and nuclear physics at the CSRe.
△ Less
Submitted 22 May, 2013;
originally announced May 2013.
-
Test of detuning system for dielectronic recombination experiment at CSRm
Authors:
L. J. Meng,
X. Ma,
V. V. Parkhomchuk,
D. Yang,
V. B. Reva,
J. Li,
L. J. Mao,
X. M. Ma,
T. L. Yan,
J. W. Xia,
Y. J. Yuan,
H. S. Xu,
J. C. Yang,
G. Q. Xiao
Abstract:
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+…
▽ More
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+ beam was performed to examine the influence of this system on the performance of the stored ion beam. The Schottky spectra and the ion beam currents were recorded to monitor the beam status. The influence of pulse heights and widths of the detuning voltage on the ion beam was investigated. For the small pulse height, the experimental results from the Schottky spectrum were in good agreement with the theoretical results. The frequency shift in the Schottky spectrum is significantly reduced for the short pulse width. For the large pulse height, an oscillation phenomenon was observed. From the Schottky spectrum, we found the oscillation amplitude is dependent on the pulse width of detuning and the ion beam intensity. The detailed description of the phenomenon and the theoretical model based on the plasma oscillation was discussed in this paper.
△ Less
Submitted 14 February, 2012;
originally announced February 2012.