Radiation-induced Acoustic Signal Denoising using a Supervised Deep Learning Framework for Imaging and Therapy Monitoring
Authors:
Zhuoran Jiang,
Siqi Wang,
Yifei Xu,
Leshan Sun,
Gilberto Gonzalez,
Yong Chen,
Q. Jackie Wu,
Liangzhong Xiang,
Lei Ren
Abstract:
Radiation-induced acoustic (RA) imaging is a promising technique for visualizing radiation energy deposition in tissues, enabling new imaging modalities and real-time therapy monitoring. However, it requires measuring hundreds or even thousands of averages to achieve satisfactory signal-to-noise ratios (SNRs). This repetitive measurement increases ionizing radiation dose and degrades the temporal…
▽ More
Radiation-induced acoustic (RA) imaging is a promising technique for visualizing radiation energy deposition in tissues, enabling new imaging modalities and real-time therapy monitoring. However, it requires measuring hundreds or even thousands of averages to achieve satisfactory signal-to-noise ratios (SNRs). This repetitive measurement increases ionizing radiation dose and degrades the temporal resolution of RA imaging, limiting its clinical utility. In this study, we developed a general deep inception convolutional neural network (GDI-CNN) to denoise RA signals to substantially reduce the number of averages. The multi-dilation convolutions in the network allow for encoding and decoding signal features with varying temporal characteristics, making the network generalizable to signals from different radiation sources. The proposed method was evaluated using experimental data of X-ray-induced acoustic, protoacoustic, and electroacoustic signals, qualitatively and quantitatively. Results demonstrated the effectiveness and generalizability of GDI-CNN: for all the enrolled RA modalities, GDI-CNN achieved comparable SNRs to the fully-averaged signals using less than 2% of the averages, significantly reducing imaging dose and improving temporal resolution. The proposed deep learning framework is a general method for few-frame-averaged acoustic signal denoising, which significantly improves RA imaging's clinical utilities for low-dose imaging and real-time therapy monitoring.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
An Artificial Intelligence-Driven Agent for Real-Time Head-and-Neck IMRT Plan Generation using Conditional Generative Adversarial Network (cGAN)
Authors:
Xinyi Li,
Yang Sheng,
Jiahan Zhang,
Wentao Wang,
Fang-Fang Yin,
Qiuwen Wu,
Yaorong Ge,
Q. Jackie Wu,
Chunhao Wang
Abstract:
Purpose: To develop an Artificial Intelligence (AI) agent for fully-automated rapid head and neck (H&N) IMRT plan generation without time-consuming inverse planning.$$…
▽ More
Purpose: To develop an Artificial Intelligence (AI) agent for fully-automated rapid head and neck (H&N) IMRT plan generation without time-consuming inverse planning.$$$$
Methods: This AI agent was trained using a conditional Generative Adversarial Network architecture. The generator, PyraNet, is a novel Deep Learning network that implements 28 classic ResNet blocks in pyramid-like concatenations. The discriminator is a customized 4-layer DenseNet. The AI agent first generates customized 2D projections at 9 template beam angles from 3D CT volume and structures of a patient. These projections are then stacked as 4D inputs of PyraNet, from which 9 radiation fluence maps are generated simultaneously. Finally, the predicted fluence maps are imported into a commercial treatment planning system (TPS) for plan integrity checks. The AI agent was built and tested upon 231 oropharyngeal plans from a TPS plan library. Only the primary plans in the sequential boost regime were studied. A customized Harr wavelet loss was adopted for fluence map comparison. Isodose distributions in test AI plans and TPS plans were qualitatively evaluated. Key dosimetric metrics were statistically compared.$$$$
Results: All test AI plans were successfully generated. Isodose gradients outside of PTV in AI plans were comparable with TPS plans. After PTV coverage normalization, $D_{mean}$ of parotids and oral cavity in AI plans and TPS plans were comparable without statistical significance. AI plans achieved comparable $D_{max}$ at 0.01cc of brainstem and cord+5mm without clinically relevant differences, but body $D_{max}$ was higher than the TPS plan results. The AI agent needs ~3s per case to predict fluence maps.$$$$
Conclusions: The developed AI agent can generate H&N IMRT plans with satisfying dosimetry quality. With rapid and fully automated implementation, it holds great potential for clinical applications.
△ Less
Submitted 4 December, 2020; v1 submitted 27 September, 2020;
originally announced September 2020.
-
An interpretable planning bot for pancreas stereotactic body radiation therapy
Authors:
Jiahan Zhang,
Chunhao Wang,
Yang Sheng,
Manisha Palta,
Brian Czito,
Christopher Willett,
Jiang Zhang,
P James Jensen,
Fang-Fang Yin,
Qiuwen Wu,
Yaorong Ge,
Q Jackie Wu
Abstract:
Pancreas stereotactic body radiotherapy treatment planning requires planners to make sequential, time consuming interactions with the treatment planning system (TPS) to reach the optimal dose distribution. We seek to develop a reinforcement learning (RL)-based planning bot to systematically address complex tradeoffs and achieve high plan quality consistently and efficiently. The focus of pancreas…
▽ More
Pancreas stereotactic body radiotherapy treatment planning requires planners to make sequential, time consuming interactions with the treatment planning system (TPS) to reach the optimal dose distribution. We seek to develop a reinforcement learning (RL)-based planning bot to systematically address complex tradeoffs and achieve high plan quality consistently and efficiently. The focus of pancreas SBRT planning is finding a balance between organs-at-risk sparing and planning target volume (PTV) coverage. Planners evaluate dose distributions and make planning adjustments to optimize PTV coverage while adhering to OAR dose constraints. We have formulated such interactions between the planner and the TPS into a finite-horizon RL model. First, planning status features are evaluated based on human planner experience and defined as planning states. Second, planning actions are defined to represent steps that planners would commonly implement to address different planning needs. Finally, we have derived a reward system based on an objective function guided by physician-assigned constraints. The planning bot trained itself with 48 plans augmented from 16 previously treated patients and generated plans for 24 cases in a separate validation set. All 24 bot-generated plans achieve similar PTV coverages compared to clinical plans while satisfying all clinical planning constraints. Moreover, the knowledge learned by the bot can be visualized and interpreted as consistent with human planning knowledge, and the knowledge maps learned in separate training sessions are consistent, indicating reproducibility of the learning process.
△ Less
Submitted 16 September, 2020;
originally announced September 2020.