Self-sensing with hollow cylindrical transducers for histotripsy enhanced aspiration mechanical thrombectomy applications
Authors:
Li Gong,
Alex R. Wright,
Kullervo Hynynen,
David E. Goertz
Abstract:
To address existing challenges with intravascular mechanical thrombectomy devices, a novel ultrasound-enhanced aspiration approach is being developed to mechanically degrade clots using cavitation. This method employs standing waves within a mm-scale hollow cylindrical transducer to generate high pressures sufficient to perform histotripsy on clots situated within the transducer lumen and generate…
▽ More
To address existing challenges with intravascular mechanical thrombectomy devices, a novel ultrasound-enhanced aspiration approach is being developed to mechanically degrade clots using cavitation. This method employs standing waves within a mm-scale hollow cylindrical transducer to generate high pressures sufficient to perform histotripsy on clots situated within the transducer lumen and generate substantial lesions. The objective of this study is to assess the feasibility of self-sensing cavitation detection by analyzing voltage signals across the transducer during treatment pulses. External ultrasound imaging of the transducer lumen validated cavitation detection. Impedance was also altered by the presence of clot material within the lumen. Experiments varying the driving voltage in water-filled lumens demonstrated changes in the relative amplitudes of the envelopes of the pulse body and ringdown portions of the voltage signals above the cavitation threshold, as well as changes in the spectral domain. In particular both broadband and ultraharmonic signals showed an increase in amplitude above the cavitation threshold. Similar temporal and spectral voltage signal changes in the presence of cavitation were also observed when treating clots within the lumen. This work demonstrates a highly sensitive method for detecting cavitation within the lumen, enabling monitoring with readily acquired signals without additional sensors in the catheter configuration. These findings hold significant potential for improving the efficacy of ultrasound-enhanced aspiration thrombectomy procedures.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
A novel forward-looking ultrasound catheter for treating vascular occlusions
Authors:
Jingjing Liu,
Alex R. Wright,
Kullervo Hynynen,
David E. Goertz
Abstract:
Thrombotic and chronic occlusions of large blood vessels are a major cause of mortality and morbidity, and so there is a need for improved treatments in many clinical circumstances. Endovascular ultrasound approaches have been shown to hold considerable potential to treat large vessel thrombotic occlusions. Here, we report the development of a novel forward-looking therapeutic ultrasound catheter…
▽ More
Thrombotic and chronic occlusions of large blood vessels are a major cause of mortality and morbidity, and so there is a need for improved treatments in many clinical circumstances. Endovascular ultrasound approaches have been shown to hold considerable potential to treat large vessel thrombotic occlusions. Here, we report the development of a novel forward-looking therapeutic ultrasound catheter approach. The design concept centers on the use of a radially polarized hollow cylindrical transducer situated at the distal tip. This approach enables a compact configuration where the central lumen can accommodate a guidewire during navigation as well as provide a route to release cavitation seeds and therapeutic agents adjacent to the site of occlusion. PZT-5H transducers with outer/inner diameters of 1.35/0.73 mm were evaluated using simulations and experiments for their capacity to project forward-looking ultrasound. A length of 2.5 mm operating in the 3rd harmonic of the length mode resonance (1.85 MHz) was selected. Catheters (1.55 mm outer diameter) were designed and fabricated with a liner, outer jacket, and braiding, where the transducers were incorporated with air-backing and a front-face matching layer. Forward-looking pressures of 2.5 MPa (peak negative) at 0.5 mm were achieved. Proof of principle vessel phantom experiments were performed demonstrating the ability to eject microbubbles in proximity to an occlusion and stimulate inertial cavitation. This approach holds potential for treating thrombotic and chronic total occlusions.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
Histotripsy of blood clots within a hollow cylindrical transducer for aspiration thrombectomy applications
Authors:
Li Gong,
Alex R. Wright,
Kullervo Hynynen,
David E. Goertz
Abstract:
Thrombolytic occlusions in stroke, pulmonary embolism and the peripheral vasculature are increasingly treated with aspiration, a catheter-based approach that employs suction to extract clots through a hollow catheter lumen. Unfortunately, aspiration is frequently unsuccessful in extracting more challenging clots, which can become corked in the distal tip. We hypothesize that clot extraction can be…
▽ More
Thrombolytic occlusions in stroke, pulmonary embolism and the peripheral vasculature are increasingly treated with aspiration, a catheter-based approach that employs suction to extract clots through a hollow catheter lumen. Unfortunately, aspiration is frequently unsuccessful in extracting more challenging clots, which can become corked in the distal tip. We hypothesize that clot extraction can be enhanced by using histotripsy to degrade the mechanical integrity of clot material within the lumen of a hollow cylindrical transducer which can be situated at the tip of an aspiration catheter. To demonstrate the feasibility of degrading clot material within the lumen of a hollow cylindrical transducer, the effect of pulsing schemes on lesion generation within clots was assessed using a retracted clot model. A radially polarized cylindrical transducer (2.5 mm and 3.3 mm for inner and outer diameter, 2.5 mm length, PZT) working at 6.1 MHz was used to degrade retracted porcine clots with pulse lengths of 10, 20, and 100 us, pulse repetition frequencies (PRF) of 100, 500, and 1000 Hz, using treatment times from 0.1 to 10 seconds (n = 5 clots per condition). 3D ultrasound scans and bisected optical examinations of treated clots confirmed the formation of liquified zones. Lesions could form within 0.1 seconds along the central axis of the transducer and then grow in diameter and length over time. The lesion volume was found to be highly dependent on the exposure scheme, with the largest lesion volume associated with the 10 us pulse length 1000 kHz PRF case. Collectively these results demonstrate the feasibility of degrading blood clots within hollow cylindrical transducers, which suggests their potential for enhancing aspiration based mechanical thrombectomy.
△ Less
Submitted 20 May, 2024;
originally announced May 2024.
-
PRETUS: A plug-in based platform for real-time ultrasound imaging research
Authors:
Alberto Gomez,
Veronika A. Zimmer,
Gavin Wheeler,
Nicolas Toussaint,
Shujie Deng,
Robert Wright,
Emily Skelton,
Jackie Matthew,
Bernhard Kainz,
Jo Hajnal,
Julia Schnabel
Abstract:
We present PRETUS -a Plugin-based Real Time UltraSound software platform for live ultrasound image analysis and operator support. The software is lightweight; functionality is brought in via independent plug-ins that can be arranged in sequence. The software allows to capture the real-time stream of ultrasound images from virtually any ultrasound machine, applies computational methods and visualis…
▽ More
We present PRETUS -a Plugin-based Real Time UltraSound software platform for live ultrasound image analysis and operator support. The software is lightweight; functionality is brought in via independent plug-ins that can be arranged in sequence. The software allows to capture the real-time stream of ultrasound images from virtually any ultrasound machine, applies computational methods and visualises the results on-the-fly.
Plug-ins can run concurrently without blocking each other. They can be implemented in C ++ and Python. A graphical user interface can be implemented for each plug-in, and presented to the user in a compact way. The software is free and open source, and allows for rapid prototyping and testing of real-time ultrasound imaging methods in a manufacturer-agnostic fashion. The software is provided with input, output and processing plug-ins, as well as with tutorials to illustrate how to develop new plug-ins for PRETUS.
△ Less
Submitted 14 September, 2021;
originally announced September 2021.
-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Measurements of Optical Scatter Versus Annealing Temperature for Amorphous Ta2O5 and TiO2:Ta2O5 Thin Films
Authors:
Elenna M. Capote,
Amy Gleckl,
Jazlyn Guerrero,
Michael Rezac,
Robert Wright,
Joshua R. Smith
Abstract:
Optical coatings formed from amorphous oxide thin films have many applications in precision measurements. The Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO) and Advanced Virgo use coatings of SiO$_2$ (silica) and TiO$_2$:Ta$_2$O$_5$ (titania doped tantala) and post-deposition annealing to 500$^\circ$C to achieve low thermal noise and low optical absorption. Optical scattering…
▽ More
Optical coatings formed from amorphous oxide thin films have many applications in precision measurements. The Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO) and Advanced Virgo use coatings of SiO$_2$ (silica) and TiO$_2$:Ta$_2$O$_5$ (titania doped tantala) and post-deposition annealing to 500$^\circ$C to achieve low thermal noise and low optical absorption. Optical scattering by these coatings is a key limit to the detectors' sensitivity. This paper describes optical scattering measurements for single-layer ion-beam-sputtered thin films on fused silica substrates: two samples of Ta$_2$O$_5$ and two of TiO$_2$:Ta$_2$O$_5$. Using an imaging scatterometer at a fixed scattering angle of 12.8$^\circ$, in-situ changes in the optical scatter of each sample were assessed during post-deposition annealing to 500$^\circ$C in vacuum. The scatter of three of the four coated optics was observed to decrease during the annealing process, by 25-30$\%$ for tantala and up to 74$\%$ for titania-doped tantala, while scatter from the fourth sample held constant. Angle-resolved scatter measurements performed before and after vacuum annealing suggests some improvement in three of four samples. These results demonstrate that post-deposition high-temperature annealing of single-layer tantala and titania-doped tantala thin films in vacuum does not lead to an increase in scatter, and may actually improve their scatter.
△ Less
Submitted 28 April, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
Direct Numerical Simulation of a Turbulent Boundary Layer on a Flat Plate Using Synthetic Turbulence Generation
Authors:
James R. Wright,
Riccardo Balin,
John W. Patterson,
John A. Evans,
Kenneth E. Jansen
Abstract:
The turbulent boundary layer over a flat plate is computed by direct numerical simulation (DNS) of the incompressible Navier-Stokes equations as a test bed for a synthetic turbulence generator (STG) inflow boundary condition. The inlet momentum thickness Reynolds number is approximately 1,000. The study provides validation of the ability of the STG to develop accurate turbulence in 5 to 7 boundary…
▽ More
The turbulent boundary layer over a flat plate is computed by direct numerical simulation (DNS) of the incompressible Navier-Stokes equations as a test bed for a synthetic turbulence generator (STG) inflow boundary condition. The inlet momentum thickness Reynolds number is approximately 1,000. The study provides validation of the ability of the STG to develop accurate turbulence in 5 to 7 boundary layer thicknesses downstream of the boundary condition. Also tested was the effect of changes in the stabilization scheme on the development of the boundary layer. Moreover, the grid resolution required for both the development region and the downstream flow is investigated when using a stabilized finite element method.
△ Less
Submitted 11 February, 2021; v1 submitted 8 October, 2020;
originally announced October 2020.
-
Long Distance Continuous Methane Emissions Monitoring with Dual Frequency Comb Spectroscopy: deployment and blind testing in complex emissions scenarios
Authors:
Sean Coburn,
Caroline B. Alden,
Robert Wright,
Griffith Wendland,
Alex Rybchuk,
Nicolas Seitz,
Ian Coddington,
Gregory B. Rieker
Abstract:
Continuous monitoring of oil and gas infrastructure is of interest for improving emissions and safety by enabling rapid identification and repair of emission sources, especially large sources that are responsible for the bulk of total emissions. We have previously demonstrated dual frequency comb spectroscopy (DCS) coupled with atmospheric modeling and inversion techniques (the DCS Observing Syste…
▽ More
Continuous monitoring of oil and gas infrastructure is of interest for improving emissions and safety by enabling rapid identification and repair of emission sources, especially large sources that are responsible for the bulk of total emissions. We have previously demonstrated dual frequency comb spectroscopy (DCS) coupled with atmospheric modeling and inversion techniques (the DCS Observing System) as a viable and accurate approach for detection, attribution and quantification of methane emissions at distances of more than 1 km under controlled, steady emissions scenarios. Here, we present the results of validation testing designed to mimic the complexity of operational well pad emissions from oil and gas production, and the first field measurements at an active oil and gas facility. The validation tests are performed single-blind (the measurement and data analysis team are not given information about the emissions) at the Methane Emissions Technology Evaluation Center (METEC) test facility. They consist of a series of scenarios ranging from a single, steady-rate emission point to multiple emission points that include intermittent releases (the METEC "R2" tests). Additionally, we present field measurements at an active natural gas storage facility demonstrating that the system can remotely and autonomously monitor methane emissions in a true industrial setting. This field verification is in a configuration designed for continuous and long-term characterization of operational and fugitive emissions. These demonstrations confirm that the DCS Observing System can provide high-confidence continuous monitoring of emissions from complex, operational facilities among natural gas infrastructure.
△ Less
Submitted 22 September, 2020;
originally announced September 2020.
-
Continuous regional trace gas source attribution using a field-deployed dual frequency comb spectrometer
Authors:
Sean Coburn,
Caroline B. Alden,
Robert Wright,
Kevin Cossel,
Esther Baumann,
Gar-Wing Truong,
Fabrizio Giorgetta,
Colm Sweeney,
Nathan R. Newbury,
Kuldeep Prasad,
Ian Coddington,
Gregory B. Rieker
Abstract:
Identification and quantification of trace gas sources is a major challenge for understanding and regulating air quality and greenhouse gas emissions. Current approaches either provide continuous but localized monitoring, or quasi-instantaneous 'snapshot-in-time' regional monitoring. There is a need for emissions detection that provides both continuous and regional coverage, because sources and si…
▽ More
Identification and quantification of trace gas sources is a major challenge for understanding and regulating air quality and greenhouse gas emissions. Current approaches either provide continuous but localized monitoring, or quasi-instantaneous 'snapshot-in-time' regional monitoring. There is a need for emissions detection that provides both continuous and regional coverage, because sources and sinks can be episodic and spatially variable. We field deploy a dual frequency comb laser spectrometer for the first time, enabling an observing system that provides continuous detection of trace gas sources over multiple-square-kilometer regions. Field tests simulating methane emissions from oil and gas production demonstrate detection and quantification of a 1.6 g min^-1 source (approximate emissions from a small pneumatic valve) from a distance of 1 km, and the ability to discern two leaks among a field of many potential sources. The technology achieves the goal of detecting, quantifying, and attributing emissions sources continuously through time, over large areas, and at emissions rates ~1000x lower than current regional approaches. It therefore provides a useful tool for monitoring and mitigating undesirable sources and closes a major information gap in the atmospheric sciences.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Modeling Terrorist Networks, Complex Systems at the Mid-range
Authors:
Philip Vos Fellman,
Roxana Wright
Abstract:
In this paper, we develop the themes presented at the 2003 Joint Complexity Conference at the London School of Economics and subsequently published in The Intelligencer (2004) and O Tempo Das Redes (2008). Following the data analysis of the 9/11 high-jacker network developed by Valdis Krebs from open sources, we apply social network theory to examine salient arguments regarding terrorism as seen f…
▽ More
In this paper, we develop the themes presented at the 2003 Joint Complexity Conference at the London School of Economics and subsequently published in The Intelligencer (2004) and O Tempo Das Redes (2008). Following the data analysis of the 9/11 high-jacker network developed by Valdis Krebs from open sources, we apply social network theory to examine salient arguments regarding terrorism as seen from the standpoint of complex adaptive systems theory. In particular, we explore the concepts of group cohesion, adhesion and alternative network mappings derived from node removal.
△ Less
Submitted 20 May, 2014;
originally announced May 2014.