-
Performance and radiation damage mitigation strategy for silicon photomultipliers on LEO space missions
Authors:
L. Burmistrov,
S. Davarpanah,
M. Heller,
T. Montaruli,
C. Trimarelli,
R. Aloisio,
F. C. T. Barbato,
I. De Mitri,
A. Di Giovanni,
G. Fontanella,
P. Savina,
C. Tönnis,
E. Moretti,
M. Ruzzarin,
J. Swakoń,
D. Wróbel
Abstract:
Space missions require lightweight, low-power consuming, radiation-tolerant components. Silicon photomultipliers are increasingly used for detecting near-UV, optical, and infrared light in space due to their compact design, low cost, low power consumption, robustness, and high photo-detection efficiency, which makes them sensitive to single photons. Although SiPMs outperform traditional photomulti…
▽ More
Space missions require lightweight, low-power consuming, radiation-tolerant components. Silicon photomultipliers are increasingly used for detecting near-UV, optical, and infrared light in space due to their compact design, low cost, low power consumption, robustness, and high photo-detection efficiency, which makes them sensitive to single photons. Although SiPMs outperform traditional photomultiplier tubes in many areas, concerns about their radiation tolerance and noise remain. In this study, we estimate the radiation effects on a satellite in sun-synchronous low Earth orbit (LEO) at an altitude of 550~km during the declining phase of solar cycle 25 (2026-2029). We evaluated silicon photomultipliers produced by the Foundation Bruno Kessler (FBK) using front-side illuminated technology with metal trenches (NUV-HD-MT), assessing their response to a 50~MeV proton beam and exposure to a $β$-radioactive source (strontium-90). Simulations with SPENVIS and Geant4 were used to validate the experimental results. Based on our findings, we propose a photosensor annealing strategy for space-based instruments.
△ Less
Submitted 28 May, 2025; v1 submitted 1 March, 2025;
originally announced March 2025.
-
Proton irradiation of plastic scintillator bars for POLAR-2
Authors:
Slawomir Mianowski,
Nicolas De Angelis,
Kamil Brylew,
Johannes Hulsman,
Tomasz Kowalski,
Sebastian Kusyk,
Zuzanna Mianowska,
Jerzy Mietelski,
Dominik Rybka,
Jan Swakon,
Damian Wrobel
Abstract:
POLAR-2, a plastic scintillator based Compton polarimeter, is currently under development and planned for a launch to the China Space Station in 2025. It is intended to shed a new light on our understanding of Gamma-Ray Bursts by performing high precision polarization measurements of their prompt emission. The instrument will be orbiting at an average altitude of 383 km with an inclination of 42°…
▽ More
POLAR-2, a plastic scintillator based Compton polarimeter, is currently under development and planned for a launch to the China Space Station in 2025. It is intended to shed a new light on our understanding of Gamma-Ray Bursts by performing high precision polarization measurements of their prompt emission. The instrument will be orbiting at an average altitude of 383 km with an inclination of 42° and will be subject to background radiation from cosmic rays and solar events. In this work, we tested the performance of plastic scintillation bars, EJ-200 and EJ-248M from Eljen Technology, under space-like conditions, that were chosen as possible candidates for POLAR-2. Both scintillator types were irradiated with 58 MeV protons at several doses from 1.89 Gy (corresponding to about 13 years in space for POLAR-2) up to 18.7 Gy, that goes far beyond the expected POLAR-2 life time. Their respective properties, expressed in terms of light yield, emission and absorption spectra, and activation analysis due to proton irradiation are discussed. Scintillators activation analyses showed a dominant contribution of $β^+$ decay with a typical for this process gamma-ray energy line of 511 keV.
△ Less
Submitted 5 July, 2023;
originally announced July 2023.
-
Temperature dependence of radiation damage annealing of Silicon Photomultipliers
Authors:
Nicolas De Angelis,
Merlin Kole,
Franck Cadoux,
Johannes Hulsman,
Tomasz Kowalski,
Sebastian Kusyk,
Slawomir Mianowski,
Dominik Rybka,
Jerome Stauffer,
Jan Swakon,
Damian Wrobel,
Xin Wu
Abstract:
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space base…
▽ More
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space based experiments where the detectors require to be compact, lightweight and capable of surviving launch conditions. A downside with the use of this novel type of detector in space conditions is its susceptibility to radiation damage. In order to understand the lifetime of SiPMs in space, both the damage sustained due to radiation as well as the subsequent recovery, or annealing, from this damage have to be studied. Here we present these studies for three different types of SiPMs from the Hamamatsu S13360 series. Both their behaviour after sustaining radiation equivalent to 2 years in low earth orbit in a typical mission is presented, as well as the recovery of these detectors while stored in different conditions. The storage conditions varied in temperature as well as in operating voltage. The study found that the annealing depends significantly on the temperature of the detectors with those stored at high temperatures recovering significantly faster and at recovering closer to the original performance. Additionally, no significant effect from a reasonable bias voltage on the annealing was observed. Finally the annealing rate as a function of temperature is presented along with various operating strategies for the future SiPM based astrophysical detector POLAR-2 as well as for future SiPM based space borne missions.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Proton Irradiation of SiPM arrays for POLAR-2
Authors:
Slawomir Mianowski,
Nicolas De Angelis,
Johannes Hulsman,
Merlin Kole,
Tomasz Kowalski,
Sebastian Kusyk,
Hancheng Li,
Zuzanna Mianowska,
Jerzy Mietelski,
Agnieszka Pollo,
Dominik Rybka,
Jianchao Sun,
Jan Swakon,
Damian Wrobel,
Xin Wu
Abstract:
POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China.
The instrument will orbit at altitudes between 340km and 450km with an inc…
▽ More
POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China.
The instrument will orbit at altitudes between 340km and 450km with an inclination of 42$^{\circ}$ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-like conditions.
In this paper we focus on the radiation damage of the silicon photomultiplier arrays S13361-6075NE-04 and S14161-6050HS-04 from Hamamatsu. The S13361 are irradiated with 58MeV protons at several doses up to 4.96Gy, whereas the newer series S14161 are irradiated at doses of 0.254Gy and 2.31Gy. Their respective performance degradation due to radiation damage are discussed. The equivalent exposure time in space for silicon photomultipliers inside POLAR-2 with a dose of 4.96Gy is 62.9 years (or 1.78 years when disregarding the shielding from the instrument). Primary characteristics of the I-V curves are an increase in the dark current and dark counts, mostly through cross-talk events. Annealing processes at $25^{\circ}C$ were observed but not studied in further detail. Biasing channels while being irradiated have not resulted in any significant impact.
Activation analyses showed a dominant contribution of $β^{+}$ particles around 511keV. These resulted primarily from copper and carbon, mostly with decay times shorter than the orbital period.
△ Less
Submitted 5 October, 2022; v1 submitted 4 October, 2022;
originally announced October 2022.
-
The Electron Paramagnetic Resonance in the study of tissue specimens
Authors:
Ireneusz Stefaniuk,
Dagmara Wróbel,
Andrzej Skrȩt,
Joanna Skrȩt-Magierło,
Tomasz Góra,
Piotr Szczerba
Abstract:
The Electron Paramagnetic Spectroscopy (EPR) is the most direct and powerful method for the detection and identification of free radicals and other species with unpaired electrons. Statistics disorders are a common gynaecological disorder occurring in women. The condition afflicts around 15% of women to the extent of impairing the quality of living. According to scientific reports as many as 50% o…
▽ More
The Electron Paramagnetic Spectroscopy (EPR) is the most direct and powerful method for the detection and identification of free radicals and other species with unpaired electrons. Statistics disorders are a common gynaecological disorder occurring in women. The condition afflicts around 15% of women to the extent of impairing the quality of living. According to scientific reports as many as 50% of women experiencing problems related to genital statistics disorders. The aim of this work was to investigate tissue taken from women with genital statistics disorders using the Electron Paramagnetic Resonance method. The studies on the tissue of women is one of the first studies in this area. In this work we observed a close relationship between the observed EPR signal and the consumption of omega 3 acids.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Properties of lithium aluminate for application as OSL dosimeter
Authors:
A. Twardak,
P. Bilski,
B. Marczewska,
J. I. Lee,
J. L. Kim,
W. Gieszczyk,
A. Piaskowska,
M. Sadel,
D. Wróbel
Abstract:
Several samples of lithium aluminate (LiAlO2) were prepared in an attempt to achieve material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. Both undoped and carbon or copper doped lithium aluminate samples were investigated. The results of preliminary study of theirs reproducibility, sensitivity, dose response characteristic and fading are presented. Applications i…
▽ More
Several samples of lithium aluminate (LiAlO2) were prepared in an attempt to achieve material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. Both undoped and carbon or copper doped lithium aluminate samples were investigated. The results of preliminary study of theirs reproducibility, sensitivity, dose response characteristic and fading are presented. Applications in mixed field (beta, alpha, neutrons) dosimetry are discussed.
△ Less
Submitted 25 February, 2014;
originally announced February 2014.
-
EPR investigation of defects in Bi12GeO20:Cr single crystal irradiated by high energy uranium ions
Authors:
I. Stefaniuk,
P. Potera,
I. Rogalska,
D. Wróbel
Abstract:
The results of investigations of EPR spectra of chromium doped $Bi_{12} GeO_{20} (BGO)$ single crystals are presented. The crystals were studied before and after irradiation by the $^{235}U$ ions with energy 9.47 MeV/u and fluency $5 \cdot 10^{2} cm^{-2}$. The effect of heating irradiated samples in air on the EPR spectra is also studied.
The results of investigations of EPR spectra of chromium doped $Bi_{12} GeO_{20} (BGO)$ single crystals are presented. The crystals were studied before and after irradiation by the $^{235}U$ ions with energy 9.47 MeV/u and fluency $5 \cdot 10^{2} cm^{-2}$. The effect of heating irradiated samples in air on the EPR spectra is also studied.
△ Less
Submitted 7 January, 2013;
originally announced January 2013.