-
Limitations due to residual interference in a fiber-based optical frequency reference at 1.55 $μ$m
Authors:
Karim Manamanni,
Tatiana Steshchenko,
Fabrice Wiotte,
Rodolphe Le Targat,
Michel Abgrall,
Olivier Lopez,
Étienne Cantin,
Paul-Éric Pottie,
Anne Amy-Klein,
Vincent Roncin,
Frédéric Du-Burck
Abstract:
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable…
▽ More
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable solutions for various applications. However, for high sensitivity and stability applications such as metrology, residual reflections induced by optical index inhomogeneities in connectors and fiber-coupled components leading to spurious interference significantly limit performance. We have examined the origin of the interference fringes superimposed on the detected signal and the limitations they cause to the frequency stability of the reference. The effects of temperature and beam power fluctuations are also examined. Our results show that the frequency stability is limited in the 10-13 range by the effect of interference fringes due to use of fiber components.
△ Less
Submitted 28 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Frequency Stability Transfer in Passive Mode-Locked Quantum-dash Laser Diode using Optical Injection Locking
Authors:
Karim Manamanni,
Tatiana Steshchenko,
Fabrice Wiotte,
Amine Chaouche-Ramdane,
Mohamed Omar Sahni,
Vincent Roncin,
Frédéric Du Burck
Abstract:
In this paper, we present an experimental study of the metrological stabilization of a solid-state frequency comb for embedded metrology applications. The comb is a passively mode-locked laser diode based on InGaAs/InP Quantum-dash structure emitting optical lines into a 9 nm bandwidth centered at 1.55 $μ$m with a repetition rate of 10.09 GHz. The frequency stabilization is achieved by optical inj…
▽ More
In this paper, we present an experimental study of the metrological stabilization of a solid-state frequency comb for embedded metrology applications. The comb is a passively mode-locked laser diode based on InGaAs/InP Quantum-dash structure emitting optical lines into a 9 nm bandwidth centered at 1.55 $μ$m with a repetition rate of 10.09 GHz. The frequency stabilization is achieved by optical injection locking of the comb with an external cavity laser diode referenced onto a metrological frequency standard. One observes the transfer of the spectral purity from the injection laser to the neighbouring modes of the injected one as well as the transfer of stability to the adjacent modes. The measurement of the long term stability highlights a frequency noise with random walk behavior specific of the passive mode locking process. Demonstration of sidebands of the injection laser at the repetition frequency of the comb also makes it possible to propose a transfer mechanism and to consider a complete stabilization of the frequency comb at a metrological stability level.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
Adiabatic spin-dependent momentum transfer in an SU(N) degenerate Fermi gas
Authors:
P. Bataille,
A. Litvinov,
I. Manai,
J. Huckans,
F. Wiotte,
A. Kaladjian,
O. Gorceix,
E. Maréchal,
B. Laburthe-Tolra,
M. Robert-de-Saint-Vincent
Abstract:
We introduce a spin-orbit coupling scheme, where a retro-reflected laser beam selectively diffracts two spin components in opposite directions. Spin sensitivity is provided by sweeping through a magnetic-field sensitive transition while dark states ensure that spontaneous emission remains low. The scheme is adiabatic and thus inherently robust. This tailored spin-orbit coupling allows simultaneous…
▽ More
We introduce a spin-orbit coupling scheme, where a retro-reflected laser beam selectively diffracts two spin components in opposite directions. Spin sensitivity is provided by sweeping through a magnetic-field sensitive transition while dark states ensure that spontaneous emission remains low. The scheme is adiabatic and thus inherently robust. This tailored spin-orbit coupling allows simultaneous measurements of the spin and momentum distributions of a strontium degenerate Fermi gas, and thus opens the path to momentum-resolved spin correlation measurements on SU(N) quantum magnets.
△ Less
Submitted 17 June, 2020; v1 submitted 30 March, 2020;
originally announced March 2020.
-
Shelving spectroscopy of the strontium intercombination line
Authors:
I. Manai,
A. Molineri,
C. Fréjaville,
C. Duval,
P. Bataille,
R. Journet,
F. Wiotte,
B. Laburthe-Tolra,
E. Maréchal,
M. Cheneau,
M. Robert-de-Saint-Vincent
Abstract:
We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct satura…
▽ More
We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct saturated fluorescence or absorption spectroscopy of the narrow line. We implement shelving spectroscopy both in directed atomic beams and hot vapor cells with isotropic atomic velocities. We measure a fractional frequency instability $\sim 2 \times 10^{-12}$ at 1 s limited by technical noise - about one order of magnitude above shot noise limitations for our experimental parameters. Our work illustrates the robustness and flexibility of a scheme that can be very easily implemented in the reference cells or ovens of most existing strontium experiments, and may find applications for low-complexity clocks.
△ Less
Submitted 18 March, 2020; v1 submitted 25 October, 2019;
originally announced October 2019.
-
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
Authors:
R. Santagata,
D. Tran,
B. Argence,
O. Lopez,
S. Tokunaga,
F. Wiotte,
H. Mouhamad,
A. Goncharov,
M. Abgrall,
Y. Le Coq,
H. Alvarez-Martinez,
R. Le Targat,
W. Lee,
D. Xu,
P. -E. Pottie,
B. Darquié,
A. Amy-Klein
Abstract:
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a…
▽ More
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a widely tunable ultra-narrow Quantum Cascade Laser (QCL), an optical frequency comb and a compact multipass cell. The QCL frequency is stabilized onto a comb controlled with a remote near-infrared ultra-stable laser, transferred through a fiber link. The resulting QCL frequency stability is below 10-15 from 0.1 to 10s and its frequency uncertainty of 4x10-14 is given by the remote frequency standards. Continuous tuning over ~400 MHz is reported. We use the apparatus to perform saturated absorption spectroscopy of methanol in the low-pressure multipass cell and demonstrate a statistical uncertainty at the kHz level on transition center frequencies, confirming its potential for driving the next generation technology required for precise spectroscopic measurements.
△ Less
Submitted 23 July, 2019;
originally announced July 2019.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Cascaded optical fiber link using the Internet network for remote clocks comparison
Authors:
Nicola Chiodo,
Nicolas Quintin,
Fabio Stefani,
Fabrice Wiotte,
Emilie Camisard,
Christian Chardonnet,
Giorgio Santarelli,
Anne Amy-Klein,
Paul-Eric Pottie,
Olivier Lopez
Abstract:
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the sp…
▽ More
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10-16 at 1-s measurement time and 1x10-19 at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.
△ Less
Submitted 22 September, 2015; v1 submitted 19 September, 2015;
originally announced September 2015.
-
Agile low phase noise radio-frequency sine wave generator applied to experiments on ultracold atoms
Authors:
Olivier Morizot,
Julien De Lapeyre De Bellair,
Fabrice Wiotte,
Olivier Lopez,
Paul-Eric Pottie,
Hélène Perrin
Abstract:
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and b…
▽ More
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and by a large memory length, more than 2.10^5 samples. By using a low noise external oscillator to clock the DDS, we demonstrate a phase noise as low as that of the master clock, that is at the level of -113 dB.rad^2/Hz at 1 Hz from the carrier for an output frequency of 3.75 MHz. The device is successfully used to confine an ultracold atomic cloud of rubidium 87 in a RF-based trap, and there is no extra heating from the RF source.
△ Less
Submitted 16 April, 2007;
originally announced April 2007.