-
Discovery of the 7-ring PAH Cyanocoronene (C$_{24}$H$_{11}$CN) in GOTHAM Observations of TMC-1
Authors:
Gabi Wenzel,
Siyuan Gong,
Ci Xue,
P. Bryan Changala,
Martin S. Holdren,
Thomas H. Speak,
D. Archie Stewart,
Zachary T. P. Fried,
Reace H. J. Willis,
Edwin A. Bergin,
Andrew M. Burkhardt,
Alex N. Byrne,
Steven B. Charnley,
Andrew Lipnicky,
Ryan A. Loomis,
Christopher N. Shingledecker,
Ilsa R. Cooke,
Anthony J. Remijan,
Michael C. McCarthy,
Alison E. Wendlandt,
Brett A. McGuire
Abstract:
We present the synthesis and laboratory rotational spectroscopy of the 7-ring polycyclic aromatic hydrocarbon (PAH) cyanocoronene (C$_{24}$H$_{11}$CN) using a laser-ablation assisted cavity-enhanced Fourier transform microwave spectrometer. A total of 71 transitions were measured and assigned between 6.8--10.6\,GHz. Using these assignments, we searched for emission from cyanocoronene in the GBT Ob…
▽ More
We present the synthesis and laboratory rotational spectroscopy of the 7-ring polycyclic aromatic hydrocarbon (PAH) cyanocoronene (C$_{24}$H$_{11}$CN) using a laser-ablation assisted cavity-enhanced Fourier transform microwave spectrometer. A total of 71 transitions were measured and assigned between 6.8--10.6\,GHz. Using these assignments, we searched for emission from cyanocoronene in the GBT Observations of TMC-1: Hunting Aromatic Molecules (GOTHAM) project observations of the cold dark molecular cloud TMC-1 using the 100\,m Green Bank Telescope (GBT). We detect a number of individually resolved transitions in ultrasensitive X-band observations and perform a Markov Chain Monte Carlo analysis to derive best-fit parameters, including a total column density of $N(\mathrm{C}_{24}\mathrm{H}_{11}\mathrm{CN}) = 2.69^{+0.26}_{-0.23} \times 10^{12}\,\mathrm{cm}^{-2}$ at a temperature of $6.05^{+0.38}_{-0.37}\,$K. A spectral stacking and matched filtering analysis provides a robust 17.3$\,σ$ significance to the overall detection. The derived column density is comparable to that of cyano-substituted naphthalene, acenaphthylene, and pyrene, defying the trend of decreasing abundance with increasing molecular size and complexity found for carbon chains. We discuss the implications of the detection for our understanding of interstellar PAH chemistry and highlight major open questions and next steps.
△ Less
Submitted 7 April, 2025;
originally announced April 2025.
-
Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
M. A. Bigentini,
C. E. Bina,
J. Bonatt,
W. M. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti
, et al. (139 additional authors not shown)
Abstract:
In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial volume that enhances dark matter candidate events identification. This paper describes three distinct position reconstruction algorithms employed by DEAP-3600, leveraging the spatial and temporal information provided by…
▽ More
In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial volume that enhances dark matter candidate events identification. This paper describes three distinct position reconstruction algorithms employed by DEAP-3600, leveraging the spatial and temporal information provided by photomultipliers surrounding a spherical liquid argon vessel. Two of these methods are maximum-likelihood algorithms: the first uses the spatial distribution of detected photoelectrons, while the second incorporates timing information from the detected scintillation light. Additionally, a machine learning approach based on the pattern of photoelectron counts across the photomultipliers is explored.
△ Less
Submitted 13 March, 2025;
originally announced March 2025.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification
Authors:
J. T. Matta,
A. J. Rowe,
M. P. Dion,
M. J. Willis,
A. D. Nicholson,
D. E. Archer,
H. H. Wightman
Abstract:
A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte-Carlo simulations were used to build the response matrix of a shielded high purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a…
▽ More
A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte-Carlo simulations were used to build the response matrix of a shielded high purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared to decay corrected values from the calibration certificate. For most nuclei in the standard ($^{241}$Am, $^{109}$Cd, $^{137}$Cs, and $^{60}$Co) the deviations from the certificate values were generally no more than $6$\% with a few outliers as high as $10$\%. For $^{57}$Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as $25$\%, driven by the meager statistics in the calibration spectra. Additionally, a complete treatment of error propagation for the technique is presented.
△ Less
Submitted 16 March, 2022; v1 submitted 21 July, 2021;
originally announced July 2021.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Adapting LIGO workflows to run in the Open Science Grid
Authors:
Edgar Fajardo,
Frank Wuerthwein,
Brian Bockelman,
Miron Livny,
Greg Thain,
James Alexander Clark,
Peter Couvares,
Josh Willis
Abstract:
During the first observation run the LIGO collaboration needed to offload some of its most, intense CPU workflows from its dedicated computing sites to opportunistic resources. Open Science Grid enabled LIGO to run PyCbC, RIFT and Bayeswave workflows to seamlessly run in a combination of owned and opportunistic resources. One of the challenges is enabling the workflows to use several heterogeneous…
▽ More
During the first observation run the LIGO collaboration needed to offload some of its most, intense CPU workflows from its dedicated computing sites to opportunistic resources. Open Science Grid enabled LIGO to run PyCbC, RIFT and Bayeswave workflows to seamlessly run in a combination of owned and opportunistic resources. One of the challenges is enabling the workflows to use several heterogeneous resources in a coordinated and effective way.
△ Less
Submitted 30 November, 2020;
originally announced November 2020.
-
Quantifying uncertainty in spatio-temporal changes of upper-ocean heat content estimates: an internationally coordinated comparison
Authors:
Abhishek Savita,
Catia M. Domingues,
Tim Boyer,
Viktor Gouretski,
Masayoshi Ishii,
Gregory C. Johnson,
John M. Lyman,
Josh K. Willis,
Simon J. Marsland,
William Hobbs,
John A. Church,
Didier P. Monselesan,
Peter Dobrohotoff,
Rebecca Cowley,
Susan E. Wijffels
Abstract:
The Earth system is accumulating energy due to human-induced activities. More than 90 percent of this energy has been stored in the ocean as heat since 1970, with about 64 percent of that in the upper 700 m. Differences in upper ocean heat content anomaly (OHCA) estimates, however, exist. Here, we evaluate spread in upper OHCA estimates arising from choices in instrumental bias corrections and map…
▽ More
The Earth system is accumulating energy due to human-induced activities. More than 90 percent of this energy has been stored in the ocean as heat since 1970, with about 64 percent of that in the upper 700 m. Differences in upper ocean heat content anomaly (OHCA) estimates, however, exist. Here, we evaluate spread in upper OHCA estimates arising from choices in instrumental bias corrections and mapping methods, in addition to the effect of using a common ocean mask. The same dataset was mapped by six research groups for 1970 to 2008, with six instrumental bias corrections applied to expendable bathythermograph (XBT) data. We find that use of a common ocean mask may impact estimation of global OHCA by +- 13 percent. Uncertainty due to mapping method dominates over XBT bias correction at a global scale and is largest in the Indian Ocean and in the eddy-rich and frontal regions of all basins. Uncertainty due to XBT bias correction is largest in the Pacific Ocean within 30N to 30S. In both mapping and XBT cases, spread is higher since the 1990s. Important differences in spatial trends among mapping methods are found in the well-observed Northwest Atlantic and the poorly-observed Southern Ocean. Although our results cannot identify the best mapping or bias correction schemes, they identify where and when greater uncertainties exist, and so where further refinements may yield the largest improvements. Our results highlight the need for a future international coordination to evaluate performance of existing mapping methods.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Green's function for longitudinal shear of a periodic laminate
Authors:
John Willis
Abstract:
The reasoning is a slight extension of that employed in my article [1] and its further development [2]. A formal solution to the title problem is presented for a general periodic laminate and its application for the construction of "effective constitutive relations" is developed. Its implementation in detail will be reported separately.
The reasoning is a slight extension of that employed in my article [1] and its further development [2]. A formal solution to the title problem is presented for a general periodic laminate and its application for the construction of "effective constitutive relations" is developed. Its implementation in detail will be reported separately.
△ Less
Submitted 5 November, 2013;
originally announced November 2013.
-
GEM operation in helium and neon at low temperatures
Authors:
A. Buzulutskov,
J. Dodd,
R. Galea,
Y. Ju,
M. Leltchouk,
P. Rehak,
V. Tcherniatine,
W. J. Willis,
A. Bondar,
D. Pavlyuchenko,
R. Snopkov,
Y. Tikhonov
Abstract:
We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains, exceeding 1000. There is an indication that this high gain is achieved by Penning effect in the gas impurities released by outgassing. At lower temperatures the…
▽ More
We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains, exceeding 1000. There is an indication that this high gain is achieved by Penning effect in the gas impurities released by outgassing. At lower temperatures the gain-voltage characteristics are significantly modified probably due to the freeze-out of impurities. In particular, the double-GEM and single-GEM structures can operate down to 2.6 K at gains reaching only several tens at a gas density of about 0.5 g/l; at higher densities the maximum gain drops further. In Ne, the maximum gain also drops at cryogenic temperatures. The gain drop in Ne at low temperatures can be reestablished in Penning mixtures of Ne+H2: very high gains, exceeding 10000, have been obtained in these mixtures at 50-60 K, at a density of 9.2 g/l corresponding to that of saturated Ne vapor near 27 K. The results obtained are relevant in the fields of two-phase He and Ne detectors for solar neutrino detection and electron avalanching at low temperatures.
△ Less
Submitted 26 April, 2005;
originally announced April 2005.