-
Derivation of Tissue Properties from Basis-Vector Model Weights for Dual-Energy CT-Based Monte Carlo Proton Beam Dose Calculations
Authors:
Maria Jose Medrano,
Xinyuan Chen,
Lucas Norberto Burigo,
Joseph A. O'Sullivan,
Jeffrey F. Williamson
Abstract:
We propose a novel method, basis vector model material indexing (BVM-MI), for predicting atomic composition and mass density from two independent basis vector model weights derived from dual-energy CT (DECT) for Monte Carlo (MC) dose planning. BVM-MI employs multiple linear regression on BVM weights and their quotient to predict elemental composition and mass density for 70 representative tissues.…
▽ More
We propose a novel method, basis vector model material indexing (BVM-MI), for predicting atomic composition and mass density from two independent basis vector model weights derived from dual-energy CT (DECT) for Monte Carlo (MC) dose planning. BVM-MI employs multiple linear regression on BVM weights and their quotient to predict elemental composition and mass density for 70 representative tissues. Predicted values were imported into the TOPAS MC code to simulate proton dose deposition to a uniform cylinder phantom composed of each tissue type. The performance of BVM-MI was compared to the conventional Hounsfield Unit material indexing method (HU-MI), which estimates elemental composition and density based on CT numbers (HU). Evaluation metrics included absolute errors in predicted elemental compositions and relative percent errors in calculated mass density and mean excitation energy. Dose distributions were assessed by quantifying absolute error in the depth of 80% maximum scored dose (R80) and relative percent errors in stopping power (SP) between MC simulations using HU-MI, BVM-MI, and benchmark compositions. Lateral dose profiles were analyzed at R80 and Bragg Peak (RBP) depths for three tissues showing the largest discrepancies in R80 depth. BVM-MI outperformed HU-MI in elemental composition predictions, with mean RMSEs of 1.30% (soft tissue) and 0.1% (bony tissue), compared to 4.20% and 1.9% for HU-MI. R80 depth RMSEs were 0.2 mm (soft) and 0.1 mm (bony) for BVM-MI, vs. 1.8 mm and 0.7 mm for HU-MI. Lateral dose profile analysis showed overall smaller dose errors for BVM-MI across core, halo, and proximal aura regions. In conclusion, fully utilizing the two-parameter BVM space for material indexing led to significantly improved TOPAS MC dose calculations over the conventional HU-MI method, demonstrating BVM-MI's potential to enhance proton therapy planning.
△ Less
Submitted 27 June, 2025;
originally announced June 2025.
-
A Metal Artifact Reduction Scheme For Accurate Iterative Dual-Energy CT Algorithms
Authors:
Tao Ge,
Maria Medrano,
Rui Liao,
Jeffrey F. Williamson,
David G. Politte,
Bruce R. Whiting,
Joseph A. O'Sullivan
Abstract:
CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning. However, the presence of metal implants introduces severe streaking artifacts in the reconstructed images, affecting the diagnostic accuracy and treatment performanc…
▽ More
CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning. However, the presence of metal implants introduces severe streaking artifacts in the reconstructed images, affecting the diagnostic accuracy and treatment performance. In order to reduce the metal artifacts in DECT, we introduce a metal-artifact reduction scheme for iterative DECT algorithms. An estimate is substituted for the corrupt data in each iteration. We utilize normalized metal-artifact reduction (NMAR) composed with image-domain decomposition to initialize the algorithm and speed up the convergence. A fully 3D joint statistical DECT algorithm, dual-energy alternating minimization (DEAM), with the proposed scheme is tested on experimental and clinical helical data acquired on a Philips Brilliance Big Bore scanner. We compared DEAM with the proposed method to the original DEAM and vendor reconstructions with and without metal-artifact reduction for orthopedic implants (O-MAR). The visualization and quantitative analysis show that DEAM with the proposed method has the best performance in reducing streaking artifacts caused by metallic objects.
△ Less
Submitted 31 January, 2022;
originally announced February 2022.
-
A Machine-learning Based Initialization for Joint Statistical Iterative Dual-energy CT with Application to Proton Therapy
Authors:
Tao Ge,
Maria Medrano,
Rui Liao,
David G. Politte,
Jeffrey F. Williamson,
Joseph A. O'Sullivan
Abstract:
Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in estimating proton stopping-power mappings from experimental 3-mm collimated phantom data. However, elapsed time of iterative DECT algorithms is not clinically acceptabl…
▽ More
Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in estimating proton stopping-power mappings from experimental 3-mm collimated phantom data. However, elapsed time of iterative DECT algorithms is not clinically acceptable, due to their low convergence rate and the tremendous geometry of modern helical CT scanners. A CNN-based initialization method is introduced to reduce the computational time of iterative DECT algorithms. DEAM is used as an example of iterative DECT algorithms in this work. The simulation results show that our method generates denoised images with greatly improved estimation accuracy for adipose, tonsils, and muscle tissue. Also, it reduces elapsed time by approximately 5-fold for DEAM to reach the same objective function value for both simulated and real data.
△ Less
Submitted 30 July, 2021;
originally announced August 2021.