Comments on Systematic Effects in the NIST Beam Neutron Lifetime Experiment
Authors:
F. E. Wietfeldt,
R. Biswas,
J. Caylor,
B. Crawford,
M. S. Dewey,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
W. M. Snow,
J. Zuchegno
Abstract:
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the is…
▽ More
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the issues raised in Serebrov, et al lead us to alter the value of the neutron lifetime reported previously.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
Geometric Optimization of a Neutron Detector for In-Flight Measurement of the Neutron Lifetime
Authors:
A. W. Nelsen,
E. G. Ballantyne,
R. E. Calvert,
C. B. Crawford,
G. L. Greene,
S. E. Vickers,
F. E. Wietfeldt
Abstract:
The recent measurement of the lifetime of the free neutron using the beam method has an 8.7 s (4$σ$) discrepancy with UCN measurements. The goal of the BL3 experiment is to improve the statistical error of this measurement and help rule out systematic uncertainties as an explanation for the discrepancy. A well-characterized neutron flux detector with flat response is essential, since the neutron f…
▽ More
The recent measurement of the lifetime of the free neutron using the beam method has an 8.7 s (4$σ$) discrepancy with UCN measurements. The goal of the BL3 experiment is to improve the statistical error of this measurement and help rule out systematic uncertainties as an explanation for the discrepancy. A well-characterized neutron flux detector with flat response is essential, since the neutron flux enters linearly into the neutron lifetime. I will present a new detector geometry optimization with uniform acceptance up to sixth order in neutron position.
△ Less
Submitted 21 October, 2020;
originally announced October 2020.
-
Neutron Polarimetry Using a Polarized 3He Cell for the aCORN Experiment
Authors:
B. C. Schafer,
W. A. Byron,
W. C. Chen,
B. Collett,
M. S. Dewey,
T. R. Gentile,
Md. T. Hassan,
G. L. Jones,
A. Komives,
F. E. Wietfeldt
Abstract:
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The depend…
▽ More
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The polarization of the NG-C beamline was found to be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.
△ Less
Submitted 25 September, 2020; v1 submitted 8 September, 2020;
originally announced September 2020.
-
A Comment on "The possible explanation of neutron lifetime beam anomaly" by A. P. Serebrov, et al
Authors:
F. E. Wietfeldt,
R. Biswas,
R. W. Haun,
M. S. Dewey,
J. Caylor,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
B. Crawford,
W. M. Snow
Abstract:
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment
Authors:
F. E. Wietfeldt,
W. A. Byron,
G. Darius,
C. R. DeAngelis,
M. T. Hassan,
M. S. Dewey,
M. P. Mendenhall,
J. S. Nico,
B. Collett,
G. L. Jones,
A. Komives,
E. J. Stephenson
Abstract:
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertaint…
▽ More
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
The aCORN Backscatter-Suppressed Beta Spectrometer
Authors:
M. T. Hassan,
F. Bateman,
B. Collett,
G. Darius,
C. DeAngelis,
M. S. Dewey,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
E. J. Stephenson,
I. Stern,
C. Trull,
F. E. Wietfeldt
Abstract:
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter ve…
▽ More
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
△ Less
Submitted 25 January, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
Precision Measurement of the Radiative $\Beta$ Decay of the Free Neutron
Authors:
M. J. Bales,
R. Alarcon,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
M. S. Dewey,
S. Gardner,
T. R. Gentile,
D. He,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was…
▽ More
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
△ Less
Submitted 26 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
Determination of the Free Neutron Lifetime
Authors:
J. David Bowman,
L. J. Broussard,
S. M. Clayton,
M. S. Dewey,
N. Fomin,
K. B. Grammer,
G. L. Greene,
P. R. Huffman,
A. T. Holley,
G. L. Jones,
C. -Y. Liu,
M. Makela,
M. P. Mendenhall,
C. L. Morris,
J. Mulholland,
K. M. Nollett,
R. W. Pattie, Jr.,
S. Penttila,
M. Ramsey-Musolf,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
W. M. Snow,
A. Steyerl,
F. E. Wietfeldt
, et al. (2 additional authors not shown)
Abstract:
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve bot…
▽ More
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
A gamma- and X-ray detector for cryogenic, high magnetic field applications
Authors:
R. L. Cooper,
R. Alarcon,
M. J. Bales,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
M. S. Dewey,
C. Fu,
T. R. Gentile,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
K. Pulliam,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarg…
▽ More
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.