Characterization and performance of the Apollon main short-pulse laser beam following its commissioning at 2 PW level
Authors:
Weipeng Yao,
Ronan Lelièvre,
Itamar Cohen,
Tessa Waltenspiel,
Amokrane Allaoua,
Patrizio Antici,
Yohan Ayoul,
Arie Beck,
Audrey Beluze,
Christophe Blancard,
Daniel Cavanna,
Mélanie Chabanis,
Sophia N. Chen,
Erez Cohen,
Quentin Ducasse,
Mathieu Dumergue,
Fouad El Hai,
Christophe Evrard,
Evgeny Filippov,
Antoine Freneaux,
Donald Cort Gautier,
Fabrice Gobert,
Franck Goupille,
Michael Grech,
Laurent Gremillet
, et al. (21 additional authors not shown)
Abstract:
We present the results of the second commissioning phase of the short-focal-length area of the Apollon laser facility (located in Saclay, France), which was performed with the main laser beam (F1), scaled to a peak power of 2 PetaWatt. Under the conditions that were tested, this beam delivered on-target pulses of maximum energy up to 45 J and 22 fs duration. Several diagnostics were fielded to ass…
▽ More
We present the results of the second commissioning phase of the short-focal-length area of the Apollon laser facility (located in Saclay, France), which was performed with the main laser beam (F1), scaled to a peak power of 2 PetaWatt. Under the conditions that were tested, this beam delivered on-target pulses of maximum energy up to 45 J and 22 fs duration. Several diagnostics were fielded to assess the performance of the facility. The on-target focal spot and its spatial stability, as well as the secondary sources produced when irradiating solid targets, have all been characterized, with the goal of helping users design future experiments. The laser-target interaction was characterized, as well as emissions of energetic ions, X-ray and neutrons recorded, all showing good laser-to-target coupling efficiency. Moreover, we demonstrated the simultaneous fielding of F1 with the auxiliary 0.5 PW F2 beam of Apollon, enabling dual beam operation. The present commissioning will be followed in 2025 by a further commissioning stage of F1 at the 8 PW level, en route to the final 10 PW goal.
△ Less
Submitted 12 December, 2024;
originally announced December 2024.
-
Saturation of the compression of two interacting magnetic flux tubes evidenced in the laboratory
Authors:
A. Sladkov,
C. Fegan,
W. Yao,
A. F. A. Bott,
S. N. Chen,
H. Ahmed,
E. D. Filippov,
R. Lelièvre,
P. Martin,
A. McIlvenny,
T. Waltenspiel,
P. Antici,
M. Borghesi,
S. Pikuz,
A. Ciardi,
E. d'Humières,
A. Soloviev,
M. Starodubtsev,
J. Fuchs
Abstract:
Interactions between magnetic fields advected by matter play a fundamental role in the Universe at a diverse range of scales. A crucial role these interactions play is in making turbulent fields highly anisotropic, leading to observed ordered fields. These in turn, are important evolutionary factors for all the systems within and around. Despite scant evidence, due to the difficulty in measuring e…
▽ More
Interactions between magnetic fields advected by matter play a fundamental role in the Universe at a diverse range of scales. A crucial role these interactions play is in making turbulent fields highly anisotropic, leading to observed ordered fields. These in turn, are important evolutionary factors for all the systems within and around. Despite scant evidence, due to the difficulty in measuring even near-Earth events, the magnetic field compression factor in these interactions, measured at very varied scales, is limited to a few. However, compressing matter in which a magnetic field is embedded, results in compression up to several thousands. Here we show, using laboratory experiments and matching three-dimensional hybrid simulations, that there is indeed a very effective saturation of the compression when two independent parallel-oriented magnetic fields regions encounter one another due to plasma advection. We found that the observed saturation is linked to a build-up of the magnetic pressure, which decelerates and redirects the inflows at their encounter point, thereby stopping further compression. Moreover, the growth of an electric field, induced by the incoming flows and the magnetic field, acts in redirecting the inflows transversely, further hampering field compression.
△ Less
Submitted 29 November, 2024; v1 submitted 18 April, 2024;
originally announced April 2024.
-
A Comprehensive Characterization of the Neutron Fields Produced by the Apollon Petawatt Laser
Authors:
Ronan Lelièvre,
Weipeng Yao,
Tessa Waltenspiel,
Itamar Cohen,
Arie Beck,
Erez Cohen,
David Michaeli,
Ishay Pomerantz,
Donald Cort Gautier,
François Trompier,
Quentin Ducasse,
Pavlos Koseoglou,
Pär-Anders Söderström,
François Mathieu,
Amokrane Allaoua,
Julien Fuchs
Abstract:
Since two decades, laser-driven neutron emissions are studied as they represent a complementary source to conventional neutron sources, with further more different characteristics (i.e. shorter bunch duration and higher number of neutrons per bunch). We report here a global, thorough characterization of the neutron fields produced at the Apollon laser facility using the secondary laser beam (F2).…
▽ More
Since two decades, laser-driven neutron emissions are studied as they represent a complementary source to conventional neutron sources, with further more different characteristics (i.e. shorter bunch duration and higher number of neutrons per bunch). We report here a global, thorough characterization of the neutron fields produced at the Apollon laser facility using the secondary laser beam (F2). A Double Plasma Mirror (DPM) was used to improve the temporal contrast of the laser which delivers pulses of 24 fs duration, a mean on-target energy of ~10 J and up to 1 shot/min. The interaction of the laser with thin targets (few tens or hundreds of nm) in ultra-high conditions produced enhanced proton beams (up to 35 MeV), which were then used to generate neutrons via the pitcher-catcher technique. The characterization of these neutron emissions is presented, with results obtained from both simulations and measurements using several diagnostics (activation samples, bubble detectors and Time-of-Flight detectors), leading to a neutron yield of ~$4.10^{7}$ neutrons/shot. Similar neutron emissions were observed during shots with and without DPM, while fewer X-rays are produced when the DPM is used, making this tool interesting to adjust the neutrons/X-rays ratio for some applications like combined neutron/X-ray radiography.
△ Less
Submitted 11 December, 2023; v1 submitted 21 November, 2023;
originally announced November 2023.