Skip to main content

Showing 1–7 of 7 results for author: Voloshin, K

Searching in archive physics. Search in all archives.
.
  1. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    Authors: A. Akindinov, V. Golovin, E. Grigoriev, Yu. Grishuk, S. Kuleshov, D. Malkevich, A. Martemiyanov, A. Nedosekin, M. Ryabinin, K. Voloshin

    Abstract: A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (… ▽ More

    Submitted 19 September, 2008; originally announced September 2008.

    Comments: Proceedings of NDIP-2008. 8 pages, 8 figures, 6 references

    Journal ref: Nucl.Instrum.Meth.A610:431-435,2009

  2. RPC with low-resistive phosphate glass electrodes as a candidate for the CBM TOF

    Authors: A. Akindinov, V. Ammosov, V. Gapienko, Yu. Grishuk, F. Guber, N. Herrmann, O. Karavichev, S. Kiselev, A. Maevskaya, V. Razin, A. Semak, A. Smirnitskiy, Yu. Sviridov, V. Tiflov, K. Voloshin, V. Zaets, B. Zagreev

    Abstract: Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes made of phosphate glass, which has bulk resistivity in the order of 10^10 Ohm cm, has been studied with MIP beam for TOF applications. The tests have yielded sat… ▽ More

    Submitted 8 December, 2006; originally announced December 2006.

    Comments: 8 pages, 6 figures, submitted to Elsevier Science

    Journal ref: Nucl.Instrum.Meth.A572:676-681,2007

  3. arXiv:physics/0606054  [pdf

    physics.ins-det

    START: low-noise efficient trigger for cosmic muons

    Authors: A. Akindinov, D. Mal'kevich, A. Smirnitskiy, K. Voloshin

    Abstract: Noise characteristics and MIP registration efficiency of the Scintillation Tile with MRS APD Light Readout (START) were measured with cosmic particles. Encouraging results open a broad range of possibilities for using START in large-scale applications, requiring low-noise, efficient and stable trigger for cosmic muons.

    Submitted 6 June, 2006; originally announced June 2006.

    Comments: 4 pages, 2 figures, submitted to Elsevier Science

  4. START as the detector of choice for large-scale muon triggering systems

    Authors: A. Akindinov, G. Bondarenko, V. Golovin, E. Grigoriev, Yu. Grishuk, D. Mal'kevich, A. Martemiyanov, A. Nedosekin, M. Ryabinin, V. Sheinkman, A. Smirnitskiy, K. Voloshin

    Abstract: Further progress in building high-granular large-scale systems based on Scintillation Tiles with MRS APD light readout (START) became possible thanks to the creation of an improved version of MRS APD. The cost of the system may now be significantly reduced by using inexpensive extruded scintillator. More than 160 START samples were assembled based on this design modification and proved to posses… ▽ More

    Submitted 24 May, 2006; originally announced May 2006.

    Comments: 7 pages, 2 figures, reported at the 4th International Conference on New Developments in Photodetection, Beaune, France, June 19-24, 2005

    Journal ref: Nucl.Instrum.Meth.A567:74-77,2006

  5. Scintillation counter with MRS APD light readout

    Authors: A. Akindinov, G. Bondarenko, V. Golovin, E. Grigoriev, Yu. Grishuk, D. Mal'kevich, A. Martemiyanov, M. Ryabinin, A. Smirnitskiy, K. Voloshin

    Abstract: START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15… ▽ More

    Submitted 27 March, 2006; originally announced March 2006.

    Comments: 6 pages, 5 figures

    Journal ref: Nucl.Instrum.Meth. A539 (2005) 172-176

  6. arXiv:physics/0502111  [pdf, ps, other

    physics.ins-det

    100 ps time-of-flight resolution of Dielectric Resistive Plate Chamber

    Authors: A. Akindinov, V. Golovin, A. Martemiyanov, V. Petrov, V. Plotnikov, A. Smirnitsky, K. Voloshin

    Abstract: Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with different applied voltages, discriminating thresholds and beam intensities. It may be stated that the time-of-flight resolution of gaseous detectors developed… ▽ More

    Submitted 21 February, 2005; originally announced February 2005.

    Comments: 5 pages, 7 figures

    Report number: Preprint ITEP 20-99

  7. arXiv:physics/0410103  [pdf, ps, other

    physics.ins-det

    Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements

    Authors: A. Akindinov, V. Golovin, A. Martemiyanov, V. Petrov, A. Smirnitskiy, K. Voloshin

    Abstract: Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have… ▽ More

    Submitted 2 December, 2004; v1 submitted 15 October, 2004; originally announced October 2004.

    Comments: 8 pages, 7 figures text formatting and figures updated for better performance slight corrections made in the text

    Report number: ITEP 45 98