Binding energies, charge radii, spins and moments: odd-odd Ag isotopes and discovery of a new isomer
Authors:
B. van den Borne,
M. Stryjczyk,
R. P. de Groote,
A. Kankainen,
D. A. Nesterenko,
L. Al Ayoubi,
P. Ascher,
O. Beliuskina,
M. L. Bissell,
J. Bonnard,
P. Campbell,
L. Canete,
B. Cheal,
C. Delafosse,
A. de Roubin,
C. S. Devlin,
T. Eronen,
R. F. Garcia Ruiz,
S. Geldhof,
M. Gerbaux,
W. Gins,
S. Grévy,
M. Hukkanen,
A. Husson,
P. Imgram
, et al. (11 additional authors not shown)
Abstract:
We report on the masses and hyperfine structure of ground and isomeric states in $^{114,116,118,120}$Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique (PI-ICR) with the JYFLTRAP mass spectrometer and the collinear laser spectroscopy beamline at the Ion Guide Isotope Separator On-Line (IGISOL) facility, Jyväskylä, Finland. We measured the masses and excitation energies,…
▽ More
We report on the masses and hyperfine structure of ground and isomeric states in $^{114,116,118,120}$Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique (PI-ICR) with the JYFLTRAP mass spectrometer and the collinear laser spectroscopy beamline at the Ion Guide Isotope Separator On-Line (IGISOL) facility, Jyväskylä, Finland. We measured the masses and excitation energies, electromagnetic moments, and charge radii, and firmly established the nuclear spins of the long-lived states. A new isomer was discovered in $^{118}$Ag and the half-lives of $^{118}$Ag long-lived states were reevaluated. We unambiguously pinned down the level ordering of all long-lived states, placing the inversion of the $I = 0^-$ and $I = 4^+$ states at $A = 118$ $(N = 71)$. Lastly, we compared the electromagnetic moments of each state to empirical single-particle moments to identify the dominant configuration where possible.
△ Less
Submitted 5 December, 2024; v1 submitted 21 October, 2024;
originally announced October 2024.
Study of radial motion phase advance during motion excitations in a Penning trap and accuracy of JYFLTRAP mass spectrometer
Authors:
D. A. Nesterenko,
T. Eronen,
Z. Ge,
A. Kankainen,
M. Vilen
Abstract:
Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic uncertainties that impose limitations on the accuracy of measurements are discussed. It was found out that the phase evolution of the radial motion of ions in a…
▽ More
Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic uncertainties that impose limitations on the accuracy of measurements are discussed. It was found out that the phase evolution of the radial motion of ions in a Penning trap during the application of radio-frequency fields leads to a systematic cyclotron frequency shift when more than one ion species is present in the trap during the cyclotron frequency measurement. An analytic expression was derived to correctly account for the shift. Cross-reference mass measurements with carbon-cluster ions have been performed providing the mass-dependent and residual uncertainties.
△ Less
Submitted 11 July, 2021;
originally announced July 2021.
A new off-line ion source facility at IGISOL
Authors:
M. Vilén,
L. Canete,
B. Cheal,
A. Giatzoglou,
R. de Groote,
A. de Roubin,
T. Eronen,
S. Geldhof,
A. Jokinen,
A. Kankainen,
I. D. Moore,
D. A. Nesterenko,
H. Penttilä,
I. Pohjalainen,
M. Reponen,
S. Rinta-Antila
Abstract:
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap…
▽ More
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap mass measurements, laser spectroscopy and atom trap experiments.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.